Dell PowerEdge C8000 Dell PowerEdge C8220 and C8220X Using the Baseboard Ma - Page 62

Threshold Settings and Converting Formulas, The Converting Formula

Page 62 highlights

FILE LOCATION: D:\Projects\User Guide\Server\Dell\Zeus\HOM\BMC Manual\BMC\C8000_BMC_HOM_section1.fm Threshold Settings and Converting Formulas The following table lists the system sensor's threshold settings and formulas for converting the sensor readings. Table 1-47. Threshold Settings and Converting Formulas Sensor Sensor Name Number The Converting Formula Upper non- Upper Upper Lower non- Lower Lower recoverable critical non- recoverable critical non- critical critical Voltage 05h 12 V Standby Actual_Reading (Volts) = ((Raw_Data x 65) + 60) x 0.001 D4 CA C1 9C A6 AF 06h 5 V Actual_Reading (Volts) = ((Raw_Data x276) + 100) x 0.0001 D0 C7 BE 9A A3 AC 07h 5 V Standby Actual_Reading (Volts) = ((Raw_Data x 277) + 80) x 0.0001 D0 C7 BE 9A A3 AC 08h 3.3 V Actual_Reading (Volts) = ((Raw_Data x 199) + 70) x 0.0001 BF B7 AE 8D 95 9E 09h 3.3 V Standby Actual_Reading (Volts) = ((Raw_Data x 197) + 100) x 0.0001 C1 B9 B0 8F 97 A0 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

62
FILE LOCATION:
D:\Projects\User Guide\Server\Dell\Zeus\HOM\BMC
Manual\BMC\C8000_BMC_HOM_section1.fm
Threshold Settings and Converting Formulas
The following table lists the system sensor’s threshold settings and formulas
for converting the sensor readings.
Table 1-47.
Threshold Settings and Converting Formulas
Sensor
Number
Sensor Name
The Converting Formula
Upper non-
recoverable
Upper
critical
Upper
non-
critical
Lower non-
recoverable
Lower
critical
Lower
non-
critical
Voltage
05h
12 V Standby
Actual_Reading (Volts) = ((Raw_Data x 65) + 60) x 0.001
D4
CA
C1
9C
A6
AF
06h
5 V
Actual_Reading (Volts) = ((Raw_Data x276) + 100) x
0.0001
D0
C7
BE
9A
A3
AC
07h
5 V Standby
Actual_Reading (Volts) = ((Raw_Data x 277) + 80) x
0.0001
D0
C7
BE
9A
A3
AC
08h
3.3 V
Actual_Reading (Volts) = ((Raw_Data x 199) + 70) x
0.0001
BF
B7
AE
8D
95
9E
09h
3.3 V Standby
Actual_Reading (Volts) = ((Raw_Data x 197) + 100) x
0.0001
C1
B9
B0
8F
97
A0