Dell EMC PowerStore Hardware Information Guide for PowerStore 1000, 1200, 3000, 3200, 5000, 5200, 7000, 9000, and 9200 Version 3.x July 2022 Rev. A05 - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 2
of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2020 - 2022 Dell Inc. or its subsidiaries. All rights reserved. Dell - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 3
Contents Additional Resources...4 Chapter 1: Platform overview...5 Description...5 Chapter 2: Base enclosure component descriptions 6 Base enclosure component overview...6 Base enclosure front view...7 System identification tags...8 Base enclosure rear view...9 Base enclosure embedded modules...10 - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 4
https:// www.dell.com/powerstoredocs. ● Troubleshooting For information about products, software updates, licensing, and service, go to https://www.dell.com/support and locate the appropriate product support page. ● Technical support For technical support and service requests, go to https://www.dell - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 5
of meeting the requirements of multiple different storage applications with support for high availability. The design includes two major configurations X model appliances PowerStore T model appliances serve Block and File services, and the software stack is deployed directly on the system. - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 6
and plastic assemblies that provide smooth, reliable contact with the enclosure slot guides and mid-plane connectors. Each carrier has a handle with a ship with two. NOTE: PowerStore 3.0.x supports FIPS certified NVRAM NVMe drives. Contact your service provider to upgrade existing non FIPS NVRAM - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 7
Midplane The midplane separates the front-facing drives from the rear-facing nodes. It distributes power and signals to all components in the enclosure. The nodes and drives plug directly into the midplane. Node Each base enclosure contains two nodes. The node is the intelligent component providing - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 8
has occurred within the enclosure. System uninitialized. Power is off. System identification tags The Service Tag and World Wide Name Seed are serialized labels for tracking hardware components. Service Tag The Service Tag for the 25-slot base enclosure is a black pull-out tag that is located - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 9
Figure 3. Service Tag location World Wide Name Seed Tag The World Wide Name (WWN) Seed Tag is a blue pull-out tag that is located between the drives - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 10
located within the embedded module. There are two supported 4-port cards: the 4-port 25GbE SFP based card and the 4-port 10GBaseT card management port ( ) ○ Service port ( ) ● One USB port (unused) ● One mini-serial port (unused) ● One micro DB9 serial port (service) NOTE: The following figure shows - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 11
locations Location Description 4-port card Mini serial port (unused) Mini-SAS HD back-end ports Micro DB9 serial port (service) 5 RJ-45 LAN connector - service port 6 RJ-45 LAN connector - system management port. Only used on PowerStore T model. Not used on PowerStore X model. 7 Non - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 12
intervals Off Green Green blinking Off White Off Description System is booting. System uninitialized. A management IP address has not been assigned. Node in Service Mode. No fault has occurred, normal operation. Node is on (main power). Node is initializing a serial over LAN session. Node is off - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 13
v2 component locations Location Description 4-port card Mini serial port (unused) Micro DB9 serial port (unused) RJ-45 LAN connector (service) 5 100 GbE 2-port QSFP28 card (Required for connecting NVMe expansion enclosures) 6 RJ 45 LAN connector (System management for PowerStore T model - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 14
Amber Off Amber blinking Off Green Off Amber Off Description Node in Service Mode. Link up with high speed. Link up with degraded speed. BaseT I/O module can interface at speeds of 1 Gb/s and 10 Gb/s and supports both Ethernet network traffic and iSCSI block protocol on the same node. Ports can be - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 15
I/O module LED status 101.200.000A.01 1 Figure 10. Base enclosure 2-port I/O module LEDs Table 8. Base enclosure 2-port I/O module LEDs LED Location Port links 1 and 2 Power fault 3 23 State Green or blue Off Green Amber Description Link up Link down Power on Power fault Figure 11. Base - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 16
inline memory modules (DIMM) ● Internal M.2 boot modules ● Internal battery backup module ● Fan modules Dual inline memory modules Twenty-four, 288-pin DIMM sockets support up to 24 DDR4 DIMMs capable of up to 1,280 GB of memory. Internal battery backup module The node includes a Lithium-ion (Li-ion - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 17
. It uses a 12-Gb/s SAS interface for communication between the nodes and the expansion enclosure. NOTE: The SAS expansion enclosure is not supported on systems that include NVMe expansion enclosures. SAS expansion enclosure front view The front of the SAS expansion enclosure includes the following - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 18
enclosure rear component locations SAS expansion enclosure link control card Link control card functions and features The link control card (LCC) supports, controls, and monitors the SAS expansion enclosure, and is the primary interconnect management element. Each LCC includes connectors for input - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 19
12-Gb/s LCC ports, LEDs, and connectors Each SAS expansion enclosure LCC shows the following ports, LEDs, and connectors: 1 2 x4 x4 # 8 7 65 4 3 Figure 15. SAS expansion enclosure LCC ports, LEDs, and connectors Table 13. SAS expansion enclosure LCC component locations Location - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 20
. Each power supply is an auto-ranging, power-factor-corrected, multi-output, offline converter with its own line cord. Each power supply supports a fully configured SAS expansion enclosure and shares load currents with the other supply. The drives and LCCs have individual soft-start switches that - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 21
Table 16. SAS expansion enclosure AC power supply and cooling module LED status (continued) LED Location Color State Description Power supply and cooling module fault LED 4 Amber On Fault Blinking During power shutdown and during overvoltage (OVP) and undervoltage protection (UVP) fault - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 22
Fabric (NVMe/OF) standard, the NVMe expansion enclosure delivers an end-to-end NVMe solution. NOTE: The NVMe expansion enclosure is not supported on systems that include SAS expansion enclosures. NOTE: The NVMe expansion enclosure requires that the base enclosure includes the v2 embedded module and - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 23
Location Description 2 2.5-inch NVMe drives 3 Drive status and activity (blue) 4 Drive fault LED (amber) 5 World Wide Name (WWN) Seed Tag 6 Service Tag Table 18. Drive status LEDs LED Location Drive power and activity 3 Color Blue Drive fault 4 Amber - State On Blinking On Off - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 24
and for daisy chaining additional NVMe expansion enclosures. ● One micro USB port (not used) ● One USB port (not used) ● Two 1GbE RJ45 management ports (for support only) 24 24 Drive 2.5 Inch NVMe expansion enclosure (ENS24) component descriptions - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 25
locations Location Description 1 100GbE ports (QSFP28) 2 Micro USB port (not used) 3 USB port (not used) 4 1GbE RJ-45 management ports (for support only) Figure 21. Access Module LEDs Table 22. Access Module LEDs LED Power status Location 1 Fault status 2 System ID 3 Daisy chain ID - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 26
power supply LEDs Table 23. NVMe expansion enclosure AC power supply LEDs LED Location State Fault Solid amber DC power (output) - Not currently supported AC power (input) Off Green Off Green Off Description Power supply or backup fault. Check cable connection. No fault. N/A N/A AC power is - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 27
Figure 23. NVMe expansion enclosure fan modules Clock Distribution Boards Two Clock Distribution Boards provide a common clock to the drives. 24 Drive 2.5 Inch NVMe expansion enclosure (ENS24) component descriptions 27 - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 28
Figure 24. NVMe expansion enclosure Clock Distribution Boards 28 24 Drive 2.5 Inch NVMe expansion enclosure (ENS24) component descriptions - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 29
5 Technical specifications Topics: • Dimensions and weight for the base enclosure • Dimensions and weight for the SAS expansion enclosure • Dimensions and weight for the NVMe expansion enclosure • Power requirements for the base enclosure • Power requirements for the SAS expansion enclosure • - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 30
Dimensions and weight for the NVMe expansion enclosure Table 26. NVMe expansion enclosure dimensions and weight Dimension Value Weight (fully populated) 26.08 kg (57.5 lb) (not including cable management arms or mounting rails) Vertical size 2 NEMA units Height 8.89 cm (3.5 in) Width 43. - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 31
Power requirements for the base enclosure Power requirements will vary depending on system configuration, loading, and environmental conditions. The table below describes the maximum expected power draw. To estimate power consumption values for your specific environment, go to https:// - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 32
Power requirements for the SAS expansion enclosure Power requirements vary depending on system configuration, loading, and environmental conditions. The table below describes the maximum expected power draw. To estimate power consumption values for your specific environment, go to https:// - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 33
Table 30. Power requirements (continued) Requirement Description AC protection 15 A fuse on each power supply, both Line and Neutral AC inlet type IEC320-C14 appliance coupler, per power zone Ride-through time 10-millisecond minimum Current sharing +/- 5% of full load between power - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 34
Table 33. Base enclosure airflow Max Airflow CFM Min Airflow CFM 165 CFM 50 CFM Max Power Usage (Watts) 850 W Environmental recovery If the system exceeds the maximum ambient temperature by approximately 10°C (18°F), the nodes in the system begin an orderly shutdown that saves cached data, and - Dell PowerStore 1200T | EMC PowerStore Hardware Information Guide for PowerStore - Page 35