Denon AVR-3805 Auto Setup Specifications

Denon AVR-3805 Manual

Denon AVR-3805 manual content summary:

  • Denon AVR-3805 | Auto Setup Specifications - Page 1
    O N I C S ( U S A ), LLC. Specifications and Setup Procedure for Non-DENON Microphone Use for AVR-3805 Auto Setup and Room EQ Function Required Microphone Specifications for DENON Auto-Setup and Room EQ • Element : Electric Condenser Microphone • Polar Pattern : Omni-directional • Sensitivity : -40
  • Denon AVR-3805 | Auto Setup Specifications - Page 2
    (for the on-screen display) with the AVR-3805 • Connect the microphone with the microphone amplifier • Turn on the AVR-3805 and the "microphone amplifier" • Turn on the "Phantom Supply" on the microphone amplifier AVR3805 Speaker Use the internal test tones for mic amp calibration. Measure the
  • Denon AVR-3805 | Auto Setup Specifications - Page 3
    D E N O N E L E C T R O N I C S ( U S A ), LLC. Push the "SYSTEM SETUP" button on AVR-3805 • Select "2. Speaker Setup" • Select "3. Channel Level" 3
  • Denon AVR-3805 | Auto Setup Specifications - Page 4
    Level measures 80 dB(C-weighted) • Once the 'Main Volume" as been set , connect the output of microphone amplifier to the RMS Volt Meter • Adjust the "microphone amplifier's gain" as the RMS Volt Meter becomes about 120[mV RMS] • Once set, exit out of 'System Setup' and turn off the AVR-3805 4
  • Denon AVR-3805 | Auto Setup Specifications - Page 5
    Microphone Amplifier • Connect the output of the microphone amplifier to the AVR-3805's front panel 'V.AUX' Left channel audio input - located behind Trap Door • Turn on the AVR-3805 • Push the "SYSTEM SETUP" button on the remote or front panel • Select "1. Auto Setup/Room EQ" • Select "5. Mic
  • Denon AVR-3805 | Auto Setup Specifications - Page 6
    D E N O N E L E C T R O N I C S ( U S A ), LLC. • Change the setting to "V.AUX L" • Press the "SYSTEM SETUP" button on the remote or front panel • Select "1. Auto Setup" 6
  • Denon AVR-3805 | Auto Setup Specifications - Page 7
    D E N O N E L E C T R O N I C S ( U S A ), LLC. • Start "Auto-Setup" Once Auto Setup and Room EQ has completed, please continue with 'System Setup' as described in the Owner's Manual. 7
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

D
E
N
O
N
E
L
E
C
T
R
O
N
I
C
S
(
U
S
A
) ,
L L C
.
1
Specifications and Setup Procedure for Non-DENON Microphone Use for AVR-3805 Auto
Setup and Room EQ Function
Required Microphone Specifications for DENON Auto-Setup and Room EQ
Element : Electric Condenser Microphone
Polar Pattern : Omni-directional
Sensitivity : -40 dBV
(0dB = 1V/1Pa)
Frequency Response : 20-20kHz Flat Response (Ex: BEHRINGER ECM-8000)
Required Microphone Amplifier Specification for DENON Auto-Setup Room EQ
Gain : 29 dB
Frequency Response : 10-30kHz Full Flat
Microphone Placement
Set the microphone using a microphone stand, or other method, at the prime listening
point
Point the top of the microphone toward the ceiling
Adjust the height so that the top of microphone to matches the height of your ear when
sitting
Listening
Height
of
Microphone