Denon AVR-5805MK2 Serial Protocol - Page 7

COMMAND and PARAMETER list

Page 7 highlights

29.Mar.06 COMMAND and PARAMETER list COMMAND PW MV CV PARAMETER ON STANDBY UP DOWN ** FL UP FL DOWN FL ** FR UP FR DOWN FR ** C UP C DOWN C ** SW1 UP SW1 DOWN SW1 ** SW2 UP SW2 DOWN SW2 ** LFE UP LFE DOWN LFE ** SLA UP SLA DOWN SLA ** SRA UP SRA DOWN SRA ** function POWER ON/STANDBY change MASTER VOLUME UP/DOWN , direct change to ***dB **:00 to 99 by ASCII , 80=0dB, 99=---(MIN) CHANNEL VOLUME UP/DOWN , direct change to ***dB ---FRONT Lch **:38 to 62 by ASCII , 50=0dB ---FRONT Rch **:38 to 62 by ASCII , 50=0dB ---CENTER ch **:38 to 62 by ASCII , 50=0dB ---SWLeft or SWFront or SWMain ch (SWch 2 or 3SP) ---SUBWOOFER (When SWch is 1SP) **:00,38 to 62 by ASCII , 50=0dB, 00=OFF ---SWRight or SWBack ch (SWch 2 or 3SP) **:00,38 to 62 by ASCII , 50=0dB, 00=OFF ---LFEch (SWch 2 or 3SP) **:00,38 to 62 by ASCII , 50=0dB, 00=OFF ---SURROUND L(A)ch **:38 to 62 by ASCII , 50=0dB ---SURROUND R(A)ch **:38 to 62 by ASCII , 50=0dB example PWON PWSTANDBY MVUP MVDOWN MV80 CVFL UP CVFL DOWN CVFL 50 CVFR UP CVFR DOWN CVFR 50 CVC UP CVC DOWN CVC 50 CVSW1 UP CVSW1 DOWN CVSW1 50 CVSW2 UP CVSW2 DOWN CVSW2 50 CVLFE UP CVLFE DOWN CVLFE 50 CVSLA UP CVSLA DOWN CVSLA 50 CVSRA UP CVSRA DOWN CVSRA 50 MV , CV COMMAND : "*" parameter uses two or three ASCII characters. (see page4 J) section) The BOLD COMMANDS are new. 7/25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

29.Mar.06
7/25
COMMAND and PARAMETER list
COMMAND
PARAMETER
function
example
PW
ON
POWER ON/STANDBY change
PWON<CR>
STANDBY
PWSTANDBY<CR>
MV
UP
MASTER VOLUME UP/DOWN , direct change to ***dB
MVUP<CR>
DOWN
MVDOWN<CR>
**
**:00 to 99 by ASCII , 80=0dB, 99=---(MIN)
MV80<CR>
CV
FL UP
CHANNEL VOLUME UP/DOWN , direct change to ***dB
CVFL UP<CR>
FL DOWN
---FRONT Lch
CVFL DOWN<CR>
FL **
**:38 to 62 by ASCII , 50=0dB
CVFL 50<CR>
FR UP
CVFR UP<CR>
FR DOWN
---FRONT Rch
CVFR DOWN<CR>
FR **
**:38 to 62 by ASCII , 50=0dB
CVFR 50<CR>
C UP
CVC UP<CR>
C DOWN
---CENTER ch
CVC DOWN<CR>
C **
**:38 to 62 by ASCII , 50=0dB
CVC 50<CR>
SW1 UP
---SWLeft or SWFront or SWMain ch (SWch 2 or 3SP)
CVSW1 UP<CR>
SW1 DOWN
---SUBWOOFER (When SWch is 1SP)
CVSW1 DOWN<CR>
SW1 **
**:00,38 to 62 by ASCII , 50=0dB, 00=OFF
CVSW1 50<CR>
SW2 UP
CVSW2 UP<CR>
SW2 DOWN
---SWRight or SWBack ch (SWch 2 or 3SP)
CVSW2 DOWN<CR>
SW2 **
**:00,38 to 62 by ASCII , 50=0dB, 00=OFF
CVSW2 50<CR>
LFE UP
CVLFE UP<CR>
LFE DOWN
---LFEch (SWch 2 or 3SP)
CVLFE DOWN<CR>
LFE **
**:00,38 to 62 by ASCII , 50=0dB, 00=OFF
CVLFE 50<CR>
SLA UP
CVSLA UP<CR>
SLA DOWN
---SURROUND L(A)ch
CVSLA DOWN<CR>
SLA **
**:38 to 62 by ASCII , 50=0dB
CVSLA 50<CR>
SRA UP
CVSRA UP<CR>
SRA DOWN
---SURROUND R(A)ch
CVSRA DOWN<CR>
SRA **
**:38 to 62
by ASCII , 50=0dB
CVSRA 50<CR>
MV , CV
COMMAND
: "*" parameter uses two or three ASCII characters. (see page4 J) section)
The BOLD COMMANDS
are new.