Electrolux E36EC75HSS Installation Instructions - Page 3

Important Notes to the Installer, Important Note to the Consumer, Depth Adjustment Filler Kit # - model

Page 3 highlights

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Overhead Cabinet Should Not Exceed a Maximum Depth of 13" (33 cm) 30" (76.2 cm) Min. Clearance Between the Top of the Cooking Platform and the Bottom of an Unprotected Wood or Metal Cabinet. 24" (61 cm) Min. when Bottom of Wood or Metal Cabinet is Protected by Not Less Than 1/8" (0.3 cm) Flame Retardant Millboard Covered With Not Less Than No. 28 MGS Sheet Steel, 0.015" (0.4 mm) Stainless Steel, 0.024" (0.6 mm) Aluminum or 0.020" (0.5 mm) Copper. 36"(91.4 cm) Min. L Min. Recommended Distance Between Rear Edge of Cutout and Nearest Combustible Surface Above Countertop 10" ( 25.4 cm) 18" (45.7 cm) If a drawer is present underneath, allow at least 8" (20.3 cm) of clearance below the countertop. CAUTION Never store flammable products in the drawer. 25" Min. (63.5 cm Min.) For dimensions E, F, G & H, see Table on page 1. 12" (30.5 cm) K Min. From Edge of Cooktop to Nearest Combustible Wall (Either Side of Unit). CAUTION To eliminate the risk of burns or fire by reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 7" (17.8 cm) beyond the bottom of the cabinets. Approximate Location of Junction Box Model 36'' (91.4 cm) Figure 3 - COUNTERTOP CUTOUT OPENING K 7½'' (19.1 cm) L 1'' (2.5 cm) Important Notes to the Installer 1. Read all instructions contained in these installation instructions before installing the cooktop. 2. Remove all packing material before connecting the electrical supply to the cooktop. 3. Observe all governing codes and ordinances. 4. Be sure to leave these instructions with the consumer. Important Note to the Consumer Keep these instructions with your Use and Care Guide for future reference. Depth Adjustment Filler Kit #903051-9010 This cooktop is designed to replace existing unit. If the depth of your countertop opening is bigger than 7¼" (18.4 cm) and less than 8½" (21.6 cm) you can order a free filler kit #903051-9010 by calling Service Center at 1-877-4ELECTROLUX (1-877-435-3287). Optional Items Available: • A 9" (22.9cm) Stainless Steel Backsplash Kit #903048-9010 • A Black Knobs Kit #903049-9010 Those kits can be order through the Service Center at 1-877-4ELECTROLUX (1-877-435-3287). However all cost related to those kits will be at customer charges. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

3
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Figure 3 – COUNTERTOP CUTOUT OPENING
CAUTION
To eliminate the risk of
burns or fire by reaching over heated
surfaces, cabinet storage space located
above the cooktop should be avoided. If
cabinet storage is provided, risk can be
reduced by installing a range hood that
projects horizontally a minimum of 7"
(17.8 cm) beyond the bottom of the
cabinets.
For dimensions
E, F, G
&
H
,
see Table on page 1.
Overhead Cabinet Should Not Exceed a
Maximum Depth of 13" (33 cm)
30" (76.2 cm) Min. Clearance
Between the Top of the Cooking
Platform and the Bottom of an
Unprotected Wood or Metal Cabinet.
24" (61 cm) Min. when Bottom
of Wood or Metal Cabinet is
Protected by Not Less Than
1/8" (0.3 cm) Flame Retardant
Millboard Covered With Not Less
Than No. 28 MGS Sheet Steel,
0.015" (0.4 mm) Stainless Steel,
0.024" (0.6 mm) Aluminum or
0.020" (0.5 mm) Copper.
Approximate Location of
Junction Box
18"
(45.7 cm)
K
Min. From
Edge of Cooktop
to Nearest
Combustible Wall
(Either Side of
Unit).
25" Min.
(63.5 cm Min.)
12"
(30.5 cm)
10"
( 25.4 cm)
L
Min.
Recommended
Distance Between
Rear Edge of
Cutout and Nearest
Combustible Surface
Above Countertop
36"(91.4 cm)
Min.
Important Notes to the Installer
1.
Read all instructions contained in these installation
instructions before installing the cooktop.
2.
Remove all packing material before connecting the
electrical supply to the cooktop.
3.
Observe all governing codes and ordinances.
4.
Be sure to leave these instructions with the consumer.
Important Note to the Consumer
Keep these instructions with your Use and Care Guide for
future reference.
Depth Adjustment Filler Kit #903051-9010
This cooktop is designed to replace existing unit. If the
depth of your countertop opening is bigger than 7¼"
(18.4 cm) and less than 8½" (21.6 cm) you can order a
free filler kit #903051-9010 by calling Service Center at
1-877-4ELECTROLUX (1-877-435-3287).
Optional Items Available:
A 9" (22.9cm) Stainless Steel Backsplash
Kit #903048-9010
A Black Knobs Kit #903049-9010
Those kits can be order through the Service Center at
1-877-4ELECTROLUX (1-877-435-3287). However all cost
related to those kits will be at customer charges.
If a drawer is present
underneath, allow at least
8" (20.3 cm) of clearance
below the countertop.
CAUTION
Never store
flammable products in
the drawer.
MODEL
K
L
36’’ (91.4 cm)
7½’’ (19.1 cm)
1
’’