Adjustment DFX-5000+ Service Manual 3. Attach the another needle to the master surface, then correspond to the another gauge measure, and tighten the hexagonal screw. ,. Tighten the hexagonal screw. -3. Attach the gauge needle to the master surface. Figure 4-12. Attaching the Another Dial Gauge 4. To eliminate any play between the dial gauge base and the dial gauge master, pull the tie band to secure the dial gauge base and the dial gauge master before you securing the thumb screws. (Do procedure with two men.) 5. Then set the black marker to the "O" position. v v .-. Figure 4-13. Setting the Black Marker to "O" Position 4-8 Rev.D
Adjustment
DFX-5000+
Service Manual
3.
Attach the another needle to the master surface, then correspond to the another gauge
measure, and tighten the hexagonal screw.
,.
-3.
Tighten the hexagonal screw.
Attach
the gauge needle to
the master surface.
Figure
4-12.
Attaching the Another Dial Gauge
4.
To eliminate any play between the dial gauge base and the dial gauge master, pull the tie band
to secure the dial gauge base and the dial gauge master before you securing the thumb
screws. (Do procedure with two men.)
5. Then set the black marker to the “O” position.
v
v
.—.
Figure 4-13. Setting the Black Marker to “O” Position
4-8
Rev.D