Fisher and Paykel RDV3-304-N Planning Guide Dual Fuel Range - Page 20

RDV3-304, Clearance Dimensions

Page 20 highlights

C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE F CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL PLAN VIEW DATUM : TOP OF COUNTERTOP C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE E MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY D MINIMUM CLEARANCE: VENTILATION HOOD D MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFACE B MINIMUM CLEARANCE: ADJACENT OVERHEAD CABINET CLEARANCE DIMENSIONS 30" Professional Range - Dual Fuel Model no: RDV3-304 Clearance Dimensions a Minimum width of ventilation hood installed above range - not shown* B Minimum vertical distance between countertop and cabinet extending above counter c Minimum clearance from left and right of range to nearest vertical combustible surface d Minimum clearance from cooking surface to: - combustible surface centred above the cooking surface - combustible covering for ventilation hood centred above the cooking surface - non-combustible surface** centred above the cooking surface e Maximum overall depth of overhead cabinetry f Distance from centre of rear burner to rear of product mm 762 457 305 1372 914 762 330 218 *IMPORTANT NOTE: For full installation and clearance details please refer to our installation manual. **Non-combustible surfaces: as defined in 'National Fuel Gas Code' (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less than 6" (152mm) must be approved by the local codes and/or by the local authority having jurisdiction. DATUM : FLOOR FRONT VIEW 0 100 200 400 millimetres PROFILE VIEW CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL INDICATES CABINETRY CLEARANCES INDICATES PRODUCT DATUM DATE: 14.07.2020 IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16''). Read the installation guide for detailed information on installing the product. For full installation instructions and specifications visit fisherpaykel.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

DATE:
14.07.2020
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
INDICATES CABINETRY CLEARANCES --------------------------------
INDICATES PRODUCT DATUM -------------------------------------------
CLEARANCE DIMENSIONS
±0" Professional Range - Dual Fuel
Model no:
RDV3-304
Clearance Dimensions
mm
a
Minimum width of ventilation hood installed above range
- not shown*
762
B
Minimum vertical distance between countertop and cabinet
extending above counter
457
c
Minimum clearance from left and right of range to nearest
vertical combustible surface
±05
d
Minimum clearance from cooking surface to:
- combustible surface centred above the cooking surface
- combustible covering for ventilation hood centred above
the cooking surface
- non-combustible surface** centred above the cooking
surface
1±72
914
762
e
Maximum overall depth of overhead cabinetry
±±0
f
Distance from centre of rear burner to rear of product
218
*IMPORTANT NOTE: For full installation and clearance details please refer to
our installation manual.
**Non-combustible surfaces: as defined in ‘National Fuel Gas Code’ (ANSI
Z223.1, Current Edition). Clearances from non-combustible materials are not
part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less
than 6" (152mm) must be approved by the local codes and/or by the local
authority having jurisdiction.
0
100
200
400
millimetres
DATUM : FLOOR
FRONT VIEW
PROFILE VIEW
DATUM :
TOP OF COUNTERTOP
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
PLAN VIEW
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
VENTILATION HOOD
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
E
D
D
B
C
C
F