Fluke 117 Fluke 114,115,117 Manual - Page 21

Surge Protection, Temperature Coefficient - specifications

Page 21 highlights

True-rms Multimeters General Specifications General Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Extended specifications are available at www.Fluke.com. Maximum voltage between any terminal and earth ground 600 V Surge Protection 6 kV peak per IEC 61010-1 600V CAT III, Pollution Degree 2 W Fuse for A input (115 & 117 only 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293) Display Digital: 6,000 counts, updates 4/sec Bar Graph: 33 segments, updates 32/sec Temperature Operating: -10 °C to + 50 °C Storage: -40 °C to + 60 °C Temperature Coefficient 0.1 x (specified accuracy)/°C (28 °C) Operating Altitude 2,000 meters Battery 9 Volt Alkaline, NEDA 1604A / IEC 6LR61 Battery Life Alkaline: 400 hours typical, without backlight Safety Compliances Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

True-rms Multimeters
General Specifications
19
General Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18
°
C to 28
°
C, with
relative humidity at 0 % to 90 %.
Extended specifications are available at www.Fluke.com.
Maximum voltage between any
terminal and earth ground
......................................
600 V
Surge Protection
.....................................................
6 kV peak per IEC 61010-1 600V CAT III,
Pollution Degree 2
W
Fuse for A input (115 & 117 only):
....................
11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)
Display
.....................................................................
Digital: 6,000 counts, updates 4/sec
Bar Graph: 33 segments, updates 32/sec
Temperature
.............................................................
Operating: -10 °C to + 50 °C
Storage: -40 °C to + 60 °C
Temperature Coefficient
.........................................
0.1 x (specified accuracy)/
°
C (<18
°
C or >28
°
C)
Operating Altitude
...................................................
2,000 meters
Battery
.......................................................................
9 Volt Alkaline, NEDA 1604A / IEC 6LR61
Battery Life
...............................................................
Alkaline: 400 hours typical, without backlight
Safety Compliances
................................................
Complies with ANSI/ISA 82.02.01 (61010-1) 2004,
CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003)
and IEC/EN 61010-1 2
nd
Edition for measurement
Category III, 600 V, Pollution Degree 2, EMC
EN61326-1