Fluke 700G07 Product Manual - Page 17

Supervisory Mode

Page 17 highlights

Set Sample Rate This function finds how often pressure is sampled and the display is updated. Selections are 0.5, 1, 3, and 10 samples/second. Note that 10/second gives the fastest response time. Set Tare Use this function to set a constant offset value which is then subtracted from the measured pressure. For example, if a tare is set at 30 psi, and the measured pressure is 37 psi, 7 psi is shown. A pressure of 27 psi is shown as -3 psi. Push  and  to set the tare value. The value, is based on the engineering units and resolution selected for display. Tare value can be set to the maximum range of the gauge. For safety, the bar graph always shows the actual pressure based on the full range of the gauge regardless of the tare position. This is done to make sure that even with a "0" reading pressure is being applied to the gauge. Pressure Gauge Operation Function Lock When set, access to each of the settable parameters above can be turned "off" to prevent unauthorized configuration changes. This is done with password protection in Supervisory mode. Push  to access Supervisory mode or  to go back to normal operation. Supervisory Mode If necessary, each user-configurable parameter can be edited when you receive the Product. Some parameters are locked and must be unlocked to configure them. Use Supervisory mode to do this. When you are in the Configure menu, and FUnC LOCK is shown, it means that there are locked parameters. To disable function lock: 1. Push  . 0 PWRD is then shown. 2. The password "101" is required to unlock Supervisory mode. Push  to put in the password entry. Hold  or  down to move faster through the selections by a factor of 10. When you stop the counter, push  and  again to move forward or backward by a factor of 1. The password is factory set and cannot be changed. 3. Push . From this point each parameter can be locked or unlocked. Push  and  to select UnLOC or LOC for 9 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

Pressure Gauge
Operation
9
Set Sample Rate
This function finds how often pressure is sampled and the
display is updated. Selections are 0.5, 1, 3, and 10
samples/second. Note that 10/second gives the fastest
response time.
Set Tare
Use this function to set a constant offset value which is
then subtracted from the measured pressure. For
example, if a tare is set at 30 psi, and the measured
pressure is 37 psi, 7 psi is shown.
A pressure of 27 psi is shown as -3 psi.
Push
and
to set the tare value. The value, is based
on the engineering units and resolution selected for
display. Tare value can be set to the maximum range of
the gauge.
For safety, the bar graph always shows the actual
pressure based on the full range of the gauge regardless
of the tare position. This is done to make sure that even
with a “0” reading pressure is being applied to the gauge.
Function Lock
When set, access to each of the settable parameters
above can be turned “off” to prevent unauthorized
configuration changes. This is done with password
protection in Supervisory mode. Push
to access
Supervisory mode or
to go back to normal operation.
Supervisory Mode
If necessary, each user-configurable parameter can be
edited when you receive the Product. Some parameters
are locked and must be unlocked to configure them. Use
Supervisory mode to do this.
When you are in the Configure menu, and
FUnC LOCK
is
shown, it means that there are locked parameters.
To disable function lock:
1.
Push
.
0 PWRD
is then shown.
2.
The password “101” is required to unlock
Supervisory mode. Push
to put in the password
entry. Hold
or
down to move faster through the
selections by a factor of 10. When you stop the
counter, push
and
again to move forward or
backward by a factor of 1. The password is factory
set and cannot be changed.
3.
Push
.
From this point each parameter can be locked or
unlocked. Push
and
to select
UnLOC
or
LOC
for
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore
.com