Fluke 902 FE 902 Users Manual - Page 29
Specifications, Electrical Specifications
View all Fluke 902 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
HVAC Clamp Meter Specifications Specifications Electrical Specifications Function Range Resolution Accuracy Voltage DC 0 - 600 V 0.1 V 1 % ± 5 counts Voltage AC (True Rms) 0 - 600 V 0.1 V 1 % ± 5 counts (50/60 Hz) Current AC (True Rms) 0 - 600 A 0.1 A 2.0 % ± 5 counts (50/60 Hz) Current DC 0 - 200 µA 0.1 µA 1.0 % ± 5 counts Resistance 0 - 999 Ω 0 - 9999 Ω 0.1 Ω 1.0 Ω 1.5 % ± 5 counts Continuity < 30 Ω Temperature -10 to 400 °C 0.1 °C 1 % ± 0.8 °C Capacitance 1-100 µF 100-1000 µF 0.1 µF 1 µF 1.9 % ± 2 counts 23
HVAC Clamp Meter
Specifications
23
Specifications
Electrical Specifications
Function
Range
Resolution
Accuracy
Voltage DC
0 – 600 V
0.1 V
1 % ± 5 counts
Voltage AC
(True Rms)
0 – 600 V
0.1 V
1 % ± 5 counts
(50/60 Hz)
Current AC
(True Rms)
0 – 600 A
0.1 A
2.0 % ± 5 counts
(50/60 Hz)
Current DC
0 - 200
µ
A
0.1
µ
A
1.0 % ± 5 counts
Resistance
0 – 999
Ω
0 – 9999
Ω
0.1
Ω
1.0
Ω
1.5 % ± 5 counts
Continuity
< 30
Ω
Temperature
-10 to 400 °C
0.1 °C
1 % ± 0.8 °C
Capacitance
1-100
µ
F
100-1000
µ
F
0.1 μF
1 μF
1.9 % ± 2 counts