Frigidaire FAQE7011KW Installation Instructions (All Languages) - Page 11

Installed Dimensions

Page 11 highlights

50.8" (129cm)* to clear open door 29.75" (75.5cm)* to front of closed door INSTALLED DIMENSIONS 27.0" (68.5cm) 36.0" (91.5cm) 51.25" (130cm) freestand dryer on floor floor line gas supply pipe on rear of gas unit 1.6" (4cm) dryer mounted on optional pedestal floor line * To obtain these minimal depth dimensions, dryer must be vented straight back. Using a quick-turn 90° elbow (right or down on freestanding dryer) adds approximately 0.75 in. (2.0 cm) to installation depth. Upward venting of exhaust on pedestal-mounted or freestanding dryer adds approximately 4 in. (10.2 cm) to installation depth. Leftward venting on pedestal-mounted or freestanding dryer adds approximately 3.75 in. (9.5 cm) to installation depth. Downward venting of exhaust on pedestal-mounted dryer adds approximately 2.25 in. (5.7 cm) to installation depth. 50.8" (129cm)* to clear open door 29.75" (75.5cm)* to front of closed door 16.9" (43cm) 3.75" (9.5cm) 13.50" (34.5cm) to center of rear vent 27.0" (68.5cm) electrical supply on rear of unit centerline height for rear vent 3.7" (9.5cm) 19.0" (48cm) 71.5" (182cm) gas supply pipe on rear of gas unit 37" (94cm) electrical supply on rear of unit centerline height for rear vent 39" (99cm) * To obtain these minimal depth dimensions, dryer must be vented straight back. Using a quick-turn 90° elbow (right) adds approximately 0.75 in. (2 cm) to installation depth. Upward venting of exhaust on stacked dryer adds approximately 4 in. (10.2 cm) to installation depth. Downward venting of exhaust on stacked dryer adds approximately 2.25 in. (6.5 cm) to installation depth. Leftward venting of exhaust on stacked dryer adds approximately 3.75 in. (9.5 cm) to installation depth. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

11
36.0”
(91.5cm)
16.9”
(43cm)
19.0”
(48cm)
51.25”
(130cm)
1.6”
(4cm)
3.75”
(9.5cm)
13.50”
(34.5cm)
to center of rear vent
3.7”
(9.5cm)
gas supply
pipe on rear
of gas unit
50.8” (129cm)*
to clear open door
29.75” (75.5cm)*
to front of closed door
27.0”
(68.5cm)
centerline
height for
rear vent
electrical
supply on
rear of unit
freestand dryer
on floor
* To obtain these minimal depth dimensions, dryer must be vented straight back.
Using a quick-turn 90° elbow (right or down on freestanding dryer) adds approximately
0.75 in. (2.0 cm) to installation depth. Upward venting of exhaust on pedestal-mounted
or freestanding dryer adds approximately 4 in. (10.2 cm) to installation depth. Leftward
venting on pedestal-mounted or freestanding dryer adds approximately 3.75 in. (9.5 cm)
to installation depth. Downward venting of exhaust on pedestal-mounted dryer adds
approximately 2.25 in. (5.7 cm) to installation depth.
floor line
floor line
dryer mounted on
optional pedestal
71.5”
(182cm)
39”
(99cm)
37”
(94cm)
gas supply
pipe on rear
of gas unit
50.8” (129cm)*
to clear open door
29.75” (75.5cm)*
to front of closed door
centerline
height for
rear vent
electrical
supply on
rear of unit
* To obtain these minimal depth dimensions, dryer must be vented straight back. Using a quick-turn 90° elbow (right) adds approximately 0.75 in. (2 cm) to
installation depth. Upward venting of exhaust on stacked dryer adds approximately 4 in. (10.2 cm) to installation depth. Downward venting of exhaust on
stacked dryer adds approximately 2.25 in. (6.5 cm) to installation depth. Leftward venting of exhaust on stacked dryer adds approximately 3.75 in. (9.5 cm) to
installation depth.
27.0”
(68.5cm)
INSTALLED DIMENSIONS