Frigidaire FHWC3025MW Use and Care Manual - Page 12

Installing The Hood, Install Range Hood, Recirculating Version, Make Electrical Connection, Warning - replacement parts

Page 12 highlights

INSTALLING THE HOOD MAKE ELECTRICAL CONNECTION WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Disconnect power. G C D A B A.White wires B. Black wires C. UL listed wire connector E D. Green (or bare) ground wire E. Home power supply cable F. UL listed or CSA approved ½" strain relief G. Green ground screw F 2. Use UL listed wire connectors and connect white wires (A) together. 3. Use UL listed wire connectors and connect black wires (B) together. WARNING Fire Hazard Electrically ground the blower. Use copper wire. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death, fire, or electrical shock. 4. Connect green (or bare) ground wire from power supply to green ground screw in terminal box and securely tighten. 5. Install terminal box cover. 6. Install the 75W (max.) Incandescent light bulb. See "Replacing the Incandescent Light Bulb" in the "Range Hood Care" section. 7. Reconnect power. Complete Installation 1.Replace grease filter if removed. See the "Range Hood Care" section. .Check the operation of the range hood fan and light. See "Range Hood Use" section. If range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown. Disconnect power and check wiring connections. NOTE To get the most efficient use from your new range hood, read the "Range Hood Use" section. 12 INSTALL RANGE HOOD (Recirculating version) 1.Lift the range hood up under cabinet and determine final location by centering beneath cabinet. Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood (See slots dimensions on page 6). Set range hood aside on a covered surface. A A A. Keyhole slot .Use ¹⁄8" (3 mm) drill bit and drill 4 pilot holes as shown. NOTE: Make the drill holes on the thin area of the slot. A. Drill pilot hole A .Install the 4 - .45 cm x 1.3 cm mounting screws in pilot holes. Leave about ¼" (6.4 mm) space between screw heads and cabinet to slide range hood into place. ¹⁄4" (6.4 mm) Power Supply Cable Installation 1.For direct wire installations, run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances. There must be enough wiring from the fused disconnect (or circuit breaker) box to make the connection in the hood electrical terminal box. NOTE Do not reconnect power until the installation is complete. .Remove the screw from the terminal box cover. Remove terminal box cover A and set aside. B A. Terminal box cover B. Screw

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

INSTALLING THE HOOD
INSTALL RANGE HOOD
(Recirculating version)
Lift the range hood up under cabinet and determine
final location by centering beneath cabinet. Mark on
the underside of cabinet the location of the 4 keyhole
mounting slots on the range hood (See slots
dimensions on page 6). Set range hood aside on a
covered surface.
Use ¹⁄
8
” (3 mm) drill bit and drill 4 pilot holes as shown.
NOTE: Make the drill holes on the thin area of the slot.
Install the 4 - .45 cm x 1.3 cm mounting screws in
pilot holes. Leave about ¼” (6.4 mm) space between
screw heads and cabinet to slide range hood into place.
Power Supply Cable Installation
For direct wire installations, run the home power
supply cable according to the National Electric Code
or CSA standards and local codes and ordinances.
There must be enough wiring from the fused disconnect
(or circuit breaker) box to make the connection in the
hood electrical terminal box.
NOTE
Do not reconnect power until the installation is
complete.
Remove the screw from the
terminal box cover.
Remove terminal box cover
and set aside.
1.
±.
².
1.
±.
A
A. Keyhole slot
A
¹⁄4”
(6.4 mm)
A
A. Drill pilot hole
A
B
A. Terminal box cover
B. Screw
MAKE ELECTRICAL CONNECTION
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Use UL listed wire connectors and connect white wires
(A) together.
3. Use UL listed wire connectors and connect black wires
(B) together.
WARNING
Fire Hazard
Electrically ground the blower. Use copper wire.
Connect ground wire to green ground screw in
terminal box. Failure to do so can result in death,
fire, or electrical shock.
4. Connect green (or bare) ground wire from power supply
to green ground screw in terminal box and securely tighten.
5. Install terminal box cover.
6.
Install the 75W (max.) Incandescent light bulb. See
“Replacing the Incandescent Light Bulb” in the “Range
Hood Care” section.
7. Reconnect power.
Complete Installation
Replace grease filter if removed. See the “Range Hood
Care” section.
Check the operation of the range hood fan and light.
See “Range Hood Use” section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
NOTE
To get the most efficient use from your new
range hood, read the “Range Hood Use” section.
1.
±.
A
B
C
D
E
F
G
A.White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) ground wire
E. Home power supply cable
F. UL listed or CSA approved
½” strain relief
G. Green ground screw