Table 5.6, Diagnostic code, Head No. /LBA
View all Fujitsu MHM2200AT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Interface When device 1 is not present: • The device 0 posts only the results of its own self-diagnosis. • The device 0 clears the BSY bit of the Status register, and generates an interrupt. Table 5.6 lists the diagnostic code written in the Error register which is 8-bit code. If the device 1 fails the self-diagnosis, the device 0 "ORs" X'80' with its own status and sets that code to the Error register. Table 5.6 Diagnostic code Code X'01' X'03' X'05' X'8x' Result of diagnostic No error detected. Data buffer compare error ROM sum check error Failure of device 1 attention: The device responds normally to this command without executing internal diagnostic test. At command issuance (I/O registers setting contents) 1F7H(CM) 1 0 0 1 0 0 0 0 1F6H(DH) x x x DV Head No. /LBA [MSB] 1F5H(CH) xx 1F4H(CL) xx 1F3H(SN) xx 1F2H(SC) xx 1F1H(FR) xx 5-52 C141-E104-03EN