Garmin Compact Reactor 40 Hydraulic Autopilot with GHC 20 Corepack Installatio - Page 9

Only One Receiving Wire, Only One Transmitting Wire, Compact Pump, Alarm

Page 9 highlights

Only One Receiving Wire If your NMEA 0183 compatible device has only one receiving wire (Rx), you must connect it to the blue wire (Tx/A) from the helm control, and leave the white wire (Tx/B) from the helm control unconnected. Wire Helm Control Wire Color - Function Blue - Tx/A (+) Ì White - Tx/B (-) Í Brown - Rx/A (+) Î NMEA 0183 Compatible Device Wire Function Rx/A (+) Rx/B (-) Tx/A (+) NMEA 2000 network (provides power to the helm control) À 12 Vdc power source Á Helm control  NMEA 0183 compatible device à Wire Helm Control Wire Color - Function N/A Ê N/A Ë Blue - Tx/A (+) Ì White - unconnected Í Brown - Rx/A (+) Î Green - Rx/B (-) Ï NMEA 0183 Compatible Device Wire Function Power NMEA 0183 ground Rx N/A Tx/A (+) Tx/B (-) NOTE: When connecting a NMEA 0183 device with only one receiving (Rx) line, you must connect the NMEA 2000 bus and the NMEA 0183 device to a common ground. Only One Transmitting Wire If your NMEA 0183 compatible device has only one transmitting wire (Tx), it must be connected to the brown wire (Rx/A) from the helm control, and the green wire (Rx/B) from the helm control must be connected to NMEA 0183 ground. NOTE: When connecting a NMEA 0183 device with only one transmitting (Tx) line, you must connect the NMEA 2000 bus and the NMEA 0183 device to a common ground. Specifications Compact Pump Specification Dimensions (H × W × D) Weight Temperature range Material ECU cable length Input voltage the ECU) (from Main power usage (from the ECU) Measurement 84.6 x 100.3 x 155.3 mm (3.3 × 4.0 × 6.1 in.) 2.2 kg (5 lb.) From -15° to 75°C (from 5° to 167°F ) • Motor frame: Powder coat gloss black • Motor end caps: Cast aluminum ADC12 • Pump body and cap: Anodized die cast ADC12 • Mounting bracket: 304 stainless steel 0.6 m (24 in.) 13.8 Vdc max. • Standby: Less than 1 A • Engaged: From 5 to 10 A • Peak: 34 A CCU Specification Measurement Dimensions (L × W × H) 170 × 90 × 50 mm (6.7 × 3.5 × 2 in.) Weight 200 g (7 oz.) Temperature range From -15° to 70°C (from 5° to 158°F) Material Fully gasketed, high-impact plastic Water resistance IEC 60529 IPX7* NMEA 2000 input voltage From 9 to 16 Vdc NMEA 2000 LEN 4 (200 mA) *The device withstands incidental exposure to water of up to 1 m for up to 30 min. For more information, go to www.garmin.com/waterrating. NMEA 2000 network (provides power to the helm control) À 12 Vdc power source Á Helm control  NMEA 0183-compatible device à Wire Helm Control Wire Color - Function N/A Ê Green - Rx/B (-) (connect to Ë NMEA 0183 ground) NMEA 0183 Compatible Device Wire Function Power NMEA 0183 ground ECU Specification Measurement Dimensions (W × H × D) 168 × 117 × 51 mm (6.6 × 4.6 × 2 in.) Weight 680 g (24 oz.) Temperature range From -15° to 60°C (from 5° to 140°F) Material Fully gasketed, high-impact aluminum alloy Water resistance IEC 60529 IPX7* Power cable length 2.7 m (9 ft.) Input voltage From 11.5 to 30 Vdc Fuse 40 A, blade-type Main power usage 1 A (not including the pump) *The device withstands incidental exposure to water of up to 1 m for up to 30 min. For more information, go to www.garmin.com/waterrating. Alarm Specification Dimensions (L×diameter) Weight Temperature range Cable length Measurement 29/32 × 1 in. (23 × 25 mm) 2.4 oz. (68 g) From 5°F to 140°F (from -15°C to 60°C) 10 ft. (3.0 m) 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Only One Receiving Wire
If your NMEA 0183 compatible device has only one receiving
wire (Rx), you must connect it to the blue wire (Tx/A) from the
helm control, and leave the white wire (Tx/B) from the helm
control unconnected.
À
NMEA 2000 network (provides power to the helm control)
Á
12 Vdc power source
Â
Helm control
Ã
NMEA 0183 compatible device
Wire
Helm Control Wire Color —
Function
NMEA 0183 Compatible
Device Wire Function
Ê
N/A
Power
Ë
N/A
NMEA 0183 ground
Ì
Blue — Tx/A (+)
Rx
Í
White — unconnected
N/A
Î
Brown — Rx/A (+)
Tx/A (+)
Ï
Green — Rx/B (-)
Tx/B (-)
NOTE:
When connecting a NMEA 0183 device with only one
receiving (Rx) line, you must connect the NMEA 2000 bus and
the NMEA 0183 device to a common ground.
Only One Transmitting Wire
If your NMEA 0183 compatible device has only one transmitting
wire (Tx), it must be connected to the brown wire (Rx/A) from the
helm control, and the green wire (Rx/B) from the helm control
must be connected to NMEA 0183 ground.
À
NMEA 2000 network (provides power to the helm control)
Á
12 Vdc power source
Â
Helm control
Ã
NMEA 0183-compatible device
Wire
Helm Control Wire Color —
Function
NMEA 0183 Compatible
Device Wire Function
Ê
N/A
Power
Ë
Green — Rx/B (-) (connect to
NMEA 0183 ground)
NMEA 0183 ground
Wire
Helm Control Wire Color —
Function
NMEA 0183 Compatible
Device Wire Function
Ì
Blue — Tx/A (+)
Rx/A (+)
Í
White — Tx/B (-)
Rx/B (-)
Î
Brown — Rx/A (+)
Tx/A (+)
NOTE:
When connecting a NMEA 0183 device with only one
transmitting (Tx) line, you must connect the NMEA 2000 bus
and the NMEA 0183 device to a common ground.
Specifications
Compact Pump
Specification
Measurement
Dimensions (H × W × D)
84.6 x 100.3 x 155.3 mm (3.3 × 4.0 ×
6.1 in.)
Weight
2.2 kg (5 lb.)
Temperature range
From -15° to 75°C (from 5° to 167°F )
Material
Motor frame: Powder coat gloss black
Motor end caps: Cast aluminum ADC12
Pump body and cap: Anodized die cast
ADC12
Mounting bracket: 304 stainless steel
ECU cable length
0.6 m (24 in.)
Input voltage
(from
the ECU)
13.8 Vdc max.
Main power usage (from
the ECU)
Standby: Less than 1 A
Engaged: From 5 to 10 A
Peak: 34 A
CCU
Specification
Measurement
Dimensions (L × W × H)
170 × 90 × 50 mm (6.7 × 3.5 × 2 in.)
Weight
200 g (7 oz.)
Temperature range
From -15° to 70°C (from 5° to 158°F)
Material
Fully gasketed, high-impact plastic
Water resistance
IEC 60529 IPX7*
NMEA 2000 input voltage
From 9 to 16 Vdc
NMEA 2000 LEN
4 (200 mA)
*The device withstands incidental exposure to water of up to 1 m for up
to 30 min. For more information, go to
www.garmin.com/waterrating
.
ECU
Specification
Measurement
Dimensions (W × H × D)
168 × 117 × 51 mm (6.6 × 4.6 × 2 in.)
Weight
680 g (24 oz.)
Temperature range
From -15° to 60°C (from 5° to 140°F)
Material
Fully gasketed, high-impact aluminum
alloy
Water resistance
IEC 60529 IPX7*
Power cable length
2.7 m (9 ft.)
Input voltage
From 11.5 to 30 Vdc
Fuse
40 A, blade-type
Main power usage
1 A (not including the pump)
*The device withstands incidental exposure to water of up to 1 m for up
to 30 min. For more information, go to
www.garmin.com/waterrating
.
Alarm
Specification
Measurement
Dimensions (L×diameter)
29
/
32
× 1 in. (23 × 25 mm)
Weight
2.4 oz. (68 g)
Temperature range
From 5°F to 140°F (from -15°C to 60°C)
Cable length
10 ft. (3.0 m)
9