GE GG40T06PVK Use and Care Manual - Page 29

Pilot Burner Lights,

Page 29 highlights

Safety Instructions Installation Instructions Operating Instructions Before You Call For Service... Care and Cleaning Problem Rumbling noise Relief valve producing popping noise or draining Not enough or no hot water Possible Causes Scale and sediment in tank. Pressure build up caused by thermal expansion to a closed system. Water usage may have exceeded the capacity of the water heater. Low gas pressure. The pilot burner may be out. Water is too hot The gas control (thermostat) may be set too low. Leaking or open hot water faucets. Check valve error codes. "ON/OFF" switch turned off. Blower unplugged. Combustion Shutoff System tripped The gas control (thermostat) is set too high. Gas Control (Thermostat) Defective. Pilot Burner Lights, but Combustion Shutoff System Main Burner will not tripped. stay lit. What To Do Clean tank. This is an unacceptable condition and must be corrected. Contact the water supplier or plumbing contractor on how to correct this. Do not plug the relief valve outlet. Wait for the water heater to recover after an abnormal demand. Check gas supply pressure and manifold pressure. Check the pilot burner. If necessary, relight using the instructions in the "Lighting The Water Heater" section of this manual. See the "Water Temperature Setting" of The Water Heater section of this manual. Make sure all faucets are closed. Refer to gas valve error code table on page 30. Turn "ON". Plug in. Verify power supply (120VAC). Contact a qualified service technician. ● See the "Water Temperature Setting" of The Water Heater section of this manual. ● Contact a qualified service technician to replace the gas control (thermostat). ● Contact a qualified service technician. CAUTION: Make certain power to water heater is "OFF" before removing protective cover FOR ANY REASON. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING. CAUTION: For your safety DO NOT attempt repair of gas piping, gas control (thermostat), burners, vent connectors or other safety devices. Refer repairs to qualified service personnel. 29 Troubleshooting Tips Customer Service

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

29
Problem
Possible Causes
What To Do
Rumbling noise
Scale and sediment
±
Clean tank.
in tank.
Relief valve
Pressure build up
±
This is an unacceptable condition and must be
producing popping
caused by thermal
corrected. Contact the water supplier or plumbing
noise or draining
expansion to a
contractor on how to correct this. Do not plug the
closed system.
relief valve outlet.
Not enough or
Water usage may have
±
Wait for the water heater to recover after an
no hot water
exceeded the capacity
abnormal demand.
of the water heater.
Low gas pressure.
±
Check gas supply pressure and manifold pressure.
The pilot burner may be out.
±
Check the pilot burner. If necessary, relight using the
instructions in the “Lighting The Water Heater”
section of this manual.
The gas control (thermostat)
±
See the “Water Temperature Setting” of The Water
may be set too low.
Heater section of this manual.
Leaking or open hot
±
Make sure all faucets are closed.
water faucets.
Check valve error codes.
±
Refer to gas valve error code table on page 30.
“ON/OFF” switch turned off.
±
Turn “ON”.
Blower unplugged.
±
Plug in. Verify power supply (120VAC).
Combustion Shutoff System
±
Contact a qualified service technician.
tripped
Water is too hot
The gas control (thermostat)
See the “Water Temperature Setting” of The Water
is set too high.
Heater section of this manual.
Gas Control (Thermostat)
Contact a qualified service technician to replace the
Defective.
gas control (thermostat).
Pilot Burner Lights, but
Combustion Shutoff System
Contact a qualified service technician.
Main Burner will not
tripped.
stay lit.
Before You Call For Service…
CAUTION: For your safety DO NOT attempt repair of gas piping, gas control (thermostat), burners, vent
connectors or other safety devices. Refer repairs to qualified service personnel.
CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.
CAUTION: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper
and dangerous operation.
VERIFY PROPER OPERATION AFTER SERVICING.