Installation Instructions, INSTALLING THE WATER LINE, CONNECT THE TUBING, TO THE REFRIGERATOR

Page 12 highlights

Installation Instructions 1 INSTALLING THE WATER LINE (CONT.) 7 CONNECT THE TUBING TO THE REFRIGERATOR NOTES: • Before making the connection to the refrigerator, be sure the refrigerator power cord is not plugged into the wall outlet. • We recommend installing a water filter if your water supply has sand or particles that could clog the screen of the refrigerator's water valve. Install it in the water line near the refrigerator. If using GE SmartConnect™ Refrigerator Tubing kit, you will need an additional tube (WX08X10002) to connect the filter. Do not cut plastic tube to install filter. Remove the access cover. Remove the plastic flexible cap from the water valve (refrigerator connection). 8 TURN THE WATER ON AT THE SHUTOFF VALVE Tighten any connections that leak. 9 PLUG IN THE REFRIGERATOR Arrange the coil of tubing so that it does not vibrate against the back of the refrigerator or against the wall. Push the refrigerator back to the wall. 10 START THE ICEMAKER On power switch models, set the icemaker power switch to the l (on) position. On feeler arm models, move the feeler arm to the ON (down) position. The icemaker will not begin to operate until it reaches its operating temperature of 15°F (-9°C) or below. It will then begin operation automatically. Place the compression nut and ferrule (sleeve) onto the end of the tubing as shown. On GE SmartConnect™ Refrigerator Tubing kit, the nuts are already assembled to the tubing. Insert the end of the tubing into the water valve connection as far as possible. While holding the tubing, tighten the fitting. For plastic tubing from a GE SmartConnect™ Refrigerator Tubing kit, insert the molded end of the tubing into the shutoff valve and tighten compression nut until it is hand tight, then tighten one additional turn with a wrench. Overtightening may cause leaks. Fasten the tubing into the clamp provided to hold it in a vertical position. You may need to pry open the clamp. 1/4″ Copper Tubing Tubing Clamp Refrigerator Connection Reattach the access cover. 1/4″ Compression Nut Ferrule (sleeve) SmartConnect™ Tubing Power switch Power switch model Feeler Arm in the STOP (up) position Feeler Arm in the ON (down) position Feeler arm model NOTE: In lower water pressure conditions, the water valve may turn on up to 3 times to deliver enough water to the icemaker. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Installation Instructions
12
CONNECT THE TUBING
TO THE REFRIGERATOR
NOTES:
Before making the connection to the refrigerator,
be sure the refrigerator power cord is not plugged
into the wall outlet.
We recommend installing a water filter if your water
supply has sand or particles that could clog the
screen of the refrigerator’s water valve. Install it in
the water line near the refrigerator. If using GE
SmartConnect
Refrigerator Tubing kit, you will
need an additional tube (WX08X10002) to connect
the filter. Do not cut plastic tube to install filter.
Remove the access cover.
Remove the plastic flexible
cap from the water valve
(refrigerator connection).
Place the compression nut and ferrule (sleeve)
onto the end of the tubing as shown. On GE
SmartConnect
Refrigerator Tubing kit,
the nuts are already assembled to the tubing.
Insert the end of the tubing into the water valve
connection as far as possible. While holding the
tubing, tighten the fitting.
For plastic tubing from a GE SmartConnect
Refrigerator Tubing kit, insert the molded end
of the tubing into the shutoff valve and tighten
compression nut until it is hand tight, then
tighten one additional turn with a wrench.
Overtightening may cause leaks.
Fasten the tubing into the clamp provided
to hold it in a vertical position. You may need
to pry open the clamp.
7
TURN THE WATER
ON AT THE
SHUTOFF VALVE
Tighten any connections
that leak.
8
Tubing Clamp
1/4
Compression
Nut
Ferrule (sleeve)
SmartConnect
Tubing
Refrigerator Connection
1/4
Copper
Tubing
PLUG IN THE REFRIGERATOR
Arrange the coil of tubing so that it does not vibrate
against the back of the refrigerator or against the
wall. Push the refrigerator back to the wall.
9
Reattach the access cover.
INSTALLING THE WATER LINE
(CONT.)
1
On power switch models, set the icemaker power
switch to the
l (on)
position. On feeler arm models,
move the feeler arm to the
ON
(down) position. The
icemaker will not begin to operate until it reaches
its operating temperature of 15°F (–9°C) or below.
It will then begin operation automatically.
NOTE:
In lower water pressure conditions, the
water valve may turn on up to 3 times to deliver
enough water to the icemaker.
START THE ICEMAKER
Power
switch
Power switch model
Feeler Arm in the
STOP
(up) position
Feeler Arm in
the
ON
(down) position
Feeler arm model
10