About the exhaust feature.
View all GE JVM3162RJSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
About the exhaust feature. GEAppliances.com Charcoal Filter The charcoal filter cannot be cleaned. It must be replaced. Order Part No. WB02X10943 from your GE supplier. If the model is not vented to the outside, the air will be recirculated through a disposable charcoal filter that helps remove smoke and odors. The charcoal filter should be replaced when it is noticeably dirty or discolored (usually after 6 to 12 months, depending on usage). See Optional Kits, page 8, for more information. To Remove the Charcoal Filter To remove the charcoal filter, first disconnect power at the main fuse or circuit breaker, or pull the plug. To remove the top grille: • open the microwave door • remove 2 screws from the top • s lide the grille to the left and forward to remove You may need to open the cabinet doors to remove the screws. Slide the filter down and out. To Install the Charcoal Filter To install a new charcoal filter, remove plastic and other outer wrapping from the new filter. Insert the top of the filter up and into the grooves on the inside of the top opening. Push the bottom of the filter in until it rests in place. Replace the grille by aligning the tabs with the cutouts on the frame and sliding the grille to the right. Replace the grille screws. 19