&& Temperature Interval Allows you to select the temperature interval for fan speed change. && Fan Control Mode Auto Lets the BIOS automatically detect the type of fan installed and sets the optimal control mode. (Default) Voltage Voltage mode is recommended for a 3-pin fan. PWM PWM mode is recommended for a 4-pin fan. && Fan Stop Enables or disables the fan stop function. You can set the temperature limit using the temperature curve. The fan stops operation when the temperature is lower than the limit. (Default: Disabled) && Temperature Displays the current temperature of the selected target area. && Fan Speed Displays current fan speeds. && Flow Rate Displays the flow rate of your water cooling system. && Temperature Warning Control Sets the warning threshold for temperature. When temperature exceeds the threshold, BIOS will emit warning sound. Options are: Disabled (default), 60oC/140oF, 70oC/158oF, 80oC/176oF, 90oC/194oF. && Fan Fail Warning Allows the system to emit warning sound if the fan is not connected or fails. Check the fan condition or fan connection when this occurs. (Default: Disabled) - 35 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

&
Temperature Interval
Allows you to select the temperature interval for fan speed change.
&
Fan Control Mode
±
Auto
Lets the BIOS automatically detect the type of fan installed and sets the optimal control
mode. (Default)
±
Voltage
Voltage mode is recommended for a 3-pin fan.
±
PWM
PWM mode is recommended for a 4-pin fan.
&
Fan Stop
Enables or disables the fan stop function. You can set the temperature limit using the temperature curve.
The fan stops operation when the temperature is lower than the limit. (Default: Disabled)
&
Temperature
Displays the current temperature of the selected target area.
&
Fan Speed
Displays current fan speeds.
&
Flow Rate
Displays the flow rate of your water cooling system.
&
Temperature Warning Control
Sets the warning threshold for temperature. When temperature exceeds the threshold, BIOS will emit
warning sound. Options are: Disabled (default), 60
o
C/140
o
F, 70
o
C/158
o
F, 80
o
C/176
o
F, 90
o
C/194
o
F.
&
Fan Fail Warning
Allows the system to emit warning sound if the fan is not connected or fails. Check the fan condition or fan
connection when this occurs. (Default: Disabled)