Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). 2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V. 3. The wiring method should be in line with the local wiring standard. 4. After installation, the power plug should be easily reached. 5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. 34 5 Power cable: 3G2.5mm 3 4G0.75mm BR 2 L N 1 Indoor unit POWER BL SUPPLY Y/G PAS24L03-N(T3) HSU-24LEA03(T3) HSU-28LEA03(T3 Outdoor unit 34 5 1 2 Power cable: 3G2.5mm 4G0.75mm 3 2 1 2 34 5 Power cable: 3G2.5mm 6G0.75mm 3 2 1 Outdoor unit 2 1 45 6 7 Indoor unit HSU-24HEA13(T3) BR POWER BL SUPPLY Y/G LN 4 1 Indoor unit HSU-24LEA13(T3) HSU-24LEA13-M BR POWER BL SUPPLY Y/G 7 6 5 Outdoor unit 34 5 Power cable: 3G2.5mm 4G0.75mm 2 1 Indoor unit HSU-24LEA03-T HSU-32LEA13-W HSU-36LEA03(T3) HSU-30LEA13(T3) Outdoor unit LN BR BL POWER SUPPLY Y/G 34 5 Power cable: 3G2.5mm 4G0.75mm 2 LN Indoor unit 1 { power plug HSU-24LEB03(T3) Outdoor unit 34 5 Power cable: 3G2.5mm 3G0.75mm 2 1 Indoor unit Outdoor unit HSU-18LEB03(T3) 12 3 34 5 Power cable: 3G2.5mm 6G0.75mm 2 1 Indoor unit AMS30H03-N(T3) HSU-30HEA13(T3) HSU-30HEA03(T3) HSU-24HEA03 PAS30H03-N(T3) BR BL POWER SUPPLY Y/G LN Outdoor unit 34 5 1 Power cable: 3G2.5mm 6G0.75mm 2 3 2 4 1 5 Indoor unit HSU-24HEA03(T3) POWER SUPPLY BR BL Y/G Outdoor unit 6(N) 7(L) 34 5 1(N) 2(L) Power cable: 3G2.5mm 4G0.75mm 2 3(C) 1 Indoor unit HSU-24LEA03 POWER SUPPLY Outdoor unit BR BL Y/G LN

  • 1
  • 2
  • 3
  • 4

3(C)
2(L)
1(N)
Connecting the indoor/outdoor Electric Cable
Removing the wiring cover
Remove terminal cover at right bottom corner of indoor unit, then
take off wiring cover by removing its screws.
When connecting the cable after installing the indoor unit
1. Insert from outside the room cable into left side of the wall hole, in which
the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable making a loop.
Indoor unit
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
2. If the fuse on PC board is broken please change it with the type ofT. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring
is not correct, proper operation can not be carried out and will cause defect.
5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the
distance between its two contacts should be not less than 3mm.
3
4G0.75mm
Power cable:
3G2.5mm
1
2
3
L
N
1
2
4
3
5
6(N)
7(L)
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
6
7
HSU-24LEA03(T3)
N
L
BL
BR
Y/G
POWER
SUPPLY
Indoor unit
Outdoor unit
POWER
SUPPLY
BL
BR
Y/G
HSU-24LEA13(T3)
1
2
3
4
5
BL
BR
Y/G
POWER
SUPPLY
HSU-24HEA03(T3)
1
2
3
4
5
1
2
3
4
5
6
7
POWER
SUPPLY
BL
BR
Y/G
HSU-24HEA13(T3)
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
N
L
1
2
3
4
5
POWER
SUPPLY
BL
BR
Y/G
Indoor unit
Outdoor unit
HSU-30HEA13(T3)
HSU-30HEA03(T3)
-
1
2
3
4
5
Indoor unit
Outdoor uni
t
HSU-24LEA03-T
N
L
POWER
SUPPLY
BL
BR
Y/G
AMS30H03-N(T3)
PAS24L03-N(T3)
HSU-32LEA13-W
If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.
1
2
N
L
HSU-24LEB03(T3)
Indoor unit
Outdoor unit
power plug
HSU-24HEA03
HSU-24LEA13-M
PAS30H03-N(T3)
HSU-36LEA03(T3)
4G0.75mm
4G0.75mm
4G0.75mm
6G0.75mm
6G0.75mm
6G0.75mm
Power cable:
3G2.5mm
Power cable:
3G2.5mm
Power cable:
3G2.5mm
Power cable:
3G2.5mm
Power cable:
3G2.5mm
Power cable:
3G2.5mm
Power cable:
3G2.5mm
1
2
3
4
5
Indoor unit
HSU-24LEA03
4G0.75mm
Outdoor unit
1
2
3
4
5
N
L
POWER
SUPPLY
BL
BR
Y/G
HSU-18LEB03(T3)
Indoor unit
Outdoor unit
3G0.75mm
Power cable:
3G2.5mm
1
2
3
4
5
HSU-30LEA13(T3)
HSU-28LEA03(T3