Haier HSU18VHJ User Manual - Page 3
G2.5mm, 3G1.5mm, NDSV12-W, NDSV18-W - air conditioner
View all Haier HSU18VHJ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Indoor unit 4G0.75mm2 1(N) 2 (L) 3(C) Outdoor unit 1(N) 2 (L) 3(C) NDSV12-W Power cable: ^POWER 3G1.5mm 2 Indoor unit 4G0.75mm2 1(N) 2 (L) 3(C) Outdoor unit A 1(N) 2 (L) 3(C) NDSV18-W Power cable: ^POWER 3G2.5mm 2 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F. 2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V. 3. The wiring method should be in line with the local wiring standard. 4. After installation, the power plug should be easily reached. 5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. Outdoor unit Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units Connection of pipes ƽ To bend a pipe, be careful not to crush the pipe, and the bending radius should be 30 to 40 mm or longer. ƽ Connecting the pipe of gas side first makes working easier. ƽ The connection pipe is specialized for R410A. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Spanner Torque wrench Pipe Diameter(ǿ) Fastening torque Liquid side6.35mm(1/4") 18N.m Liquid/Gas side9.52mm(3/8") 42 N.m Gas side 12.7mm(1/2") 55N.m Gas side 15.88mm(5/8") 60 N.m Ensure that on dirt or debris enters the pipe. The standard pipe length is 5m. If it is over 10m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge additional refrigerant. CAUTION B Indoor unit A Outdoor unit Outdoor unit B A Oil trap Indoor unit Outdoor unit B A Indoor unit ● Max.Elevation: Amax1=10m(for 12k) Amax2=15m(for 18k) ● In case the elevation A is more than 5m, oil trap shoud be installed every 5~7m ● Max. Length: Bmax1=15m(for 12k) Bmax2= 25m(for 18k) ● In case the pipe length B is more than 10m̹the refrigerant should be charged, according to 20 g/m. Connection ƽ Take off the panel(top), by removing the 5 screws. ƽ Remove the plugs on the conduit plate. ƽ Temporarily mount the conduit tubes on the conduit plate. ƽ Connect both the power supply and unit wire harness to the corresponding terminals on the terminal board. ƽ Ground the unit in accordance with local codes. ƽ Allow several extra inches of wire for making wiring connections. ƽ Use lock nuts to secure conduit tubes. Attaching Drain-Elbow ƽ If the drain-elbow is used, please attach it as figure. (Note: Only for heat pump unit.) Purging Method:To use vacuum pump 1. Detach the service port's cap of 3-way valve, the valve rod's cap for 2-way valve and 3-way's, connect the service port into the projection of charge hose (Iow) for gaugemanifold. Then connect the projection of charge hose (center) for gaugemanifold into vacuum pump. 2. Open the handle at Iow in gaugemanifold, operate vacuum pump. If the scale- moves of gause (Iow) reach vacuum condition in a moment, check 1. again. 3. Vacuum for over 15min. And check the gauge which should read -0.1MPa (76 cm Hg) at Iow pressure side. After the completion of vacuuming, close the handle 'Lo' in gaugemanifold and stop the operation of the vacuum pump. Check condition of the scale and hold it for 1-2min. If the scale-moves back in spite of tightening, make flaring work again, the return to the beginning of 3 . 4.Open the valve rod for the 2-way valve counterclockwise to 90 degrees. After 6 seconds, close the 2-way valve and make the inspection of gas leakage. 3