Hamilton Beach HMI200 Operation Manual - Page 7
Troubleshooting Guide, Special Operating and Cleaning Instructions for Institutional Use,
UPC - 040094908554
View all Hamilton Beach HMI200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Special Operating and Cleaning Instructions for Institutional Use Preparing Infant Formulas and Similar Nutritional Adult Products Refer to the instructions for installing and mixing with the cutting blades. Be sure that the mixer and any containers have been properly cleaned and sanitized before using. Follow the additional guidelines below: 1. Always clean the cutter attachment thoroughly between different formula types to avoid cross contamination. The attachment should be removed and washed with detergent, then rinsed thoroughly, before mixing a new type of product. 2. Measure powder or liquid ingredients for the formula mixture. Add approximately half of the final volume of water to the mixing container. 3. Mix formula for 15-60 seconds on low power until all traces of powder have been incorporated into the liquid, or until all liquid ingredients are thoroughly blended. 4. Add remaining water and blend 15-30 seconds on low power. NOTE: Some very difficult to blend powdered formulas may require using a slightly longer blending time or high power. Special Cleaning Instructions for Hospital and Institutional Use To ensure that the mixer and blades remain sanitary, follow the special cleaning instructions below. 1. Wash the cutter attachment with an approved detergent after every use, including when changing formula types, as described in the section "General Cleaning with the Attachment in Place" on page 6. 2. At least once per day, sanitize the cutter attachment per the "Sanitizing" instructions on page 6, or as required to meet local sanitation codes. 3. After cleaning, attachments should be air dried and stored in a closed container or wrapped to protect them from contamination. The cutter attachment may also be washed and autoclaved by the hospital's central processing department. Be sure to follow all required safety and sanitation codes. Troubleshooting Guide Problem . . . Immersion mixer will not turn on Excessive noise or vibration Motor strains or stops Poor results (See also Tips) Solution . . . • Make sure the mixer is plugged in. • Check for a blown fuse. • Make sure that the blade assembly is properly installed. • Make sure that the blade does not contact the sides or bottom of the container. • Reduce the amount of product in the bowl. Mix thick products in smaller batches. • Make sure ingredients are prepared properly for mixing. • Reduce the amount of product. • Process for a longer or shorter period of time. • Adjust the mixing speed. Accessories Part Number HMIA 200B Description Detachable blade/shaft assembly 7