Hayward Aqua Plus Model: PL-PLUS-16V Installation - Page 24

Configuration Setup

Page 24 highlights

Flow Switch The flow switch cable plugs into the Aqua Plus 16v Control Center as shown in the diagram on page 12. Ensure that the connector catch "snaps" in order to provide a reliable connection. Turbo Cell The Turbo Cell should be plugged in after the Aqua Plus 16v cover panel is put back in place. Refer to page 12 for the location of the connector. External Input Interlock The External Input Interlock provides a means to force the filter pump or an Aux output off when certain conditions exists. A normally open or normally closed on/off external device must be connected to the Aqua Plus 16v as shown below. After properly configuring the Aqua Plus 16v (see Configuration), the filter pump and/or desired Aux will be forced off when the device is active. SPST External Switch (either Normally Open or Normally Closed) Hayward Aqua Rite Chlorinator The Aqua Plus 16v can control one or more Hayward Aqua Rite chlorinators when additional sanitizing capacity is required. A 4 wire connection is used to communicate to the Aqua Rite and can be wired up to 500' apart. Any outdoor rated 4 conductor cable can be used. Refer to the wiring diagrams below for proper wiring connection to the Aqua Rite. NOTE: There must be only 1 "primary" unit. All other Aqua Rite units must be configured as "secondary". Jumper Installed For Primary (Factory Default) Aqua Plus 16v Aqua Rite (Primary) 4 GREEN 3 YELLOW 2 BLACK 1 RED Jumper Removed For Secondary(s) Aqua Rite (Secondary) Additional Aqua Rite(s) (if required) NOTE: Primary/Secondary jumper is located underneath small circuit board. Aqua Plus GRN 4 YEL 3 BLK 2 RED 1 green 4 GRN Aqua Rite yellow bl ack 3 YEL 2 BLK red 1 RED 21 5. Configuration Setup After plumbing and wiring are complete, the Aqua Plus 16v MUST BE CONFIGURED before attempting to operate. Configuration information is entered at the keypad and "tells" the Aqua Plus 16v what equipment is connected and how each should be controlled. Group Function The Aqua Plus 16v offers the ability to assign a Group function to a particular button. Instead of a button controlling one particular function, the button can be programmed to initiate a sequence of commands that are programmed in the Configuration Menu. For example, instead of the Lights button turning on and off the pool light only, the button can be programmed to turn on the pool light, turn on the bug light, turn off the pool cleaner, turn on and dim the patio lights, turn on the music, etc. all at the same time. This convenient feature is offered on all Aux buttons, both Valve buttons and the Lights button. The Aqua Plus 16v can be programmed to control up to four groups. Refer to this section when programming Group commands. Before assigning and configuring all the desired functions and their control parameters, the group itself must be configured. The options for controlling groups are Manual On/Off, Countdown Timer, and Timeclock. The group will turn on and off based on this selection. When setting up a Group function in the Configuration Menu, the first menu allows you to select the control parameter (how the group is activated and de-activated) and the second menu allows you to select which Aqua Plus 16v functions are to be controlled in the group. A table of functions and their corresponding control parameters are listed below. Function Pool/Spa Pool Filter Lights (standard relay) Lights (dimmer relay) Spa Filter Aux1-14 (standard relay) Aux1-14 (dimmer relay) Valve3 Valve4 Spa Htr1 Set Pool Htr1 Set Spa Htr2 Set Pool Htr2 Set Spa Solar Set Pool Solar Set SuperChlr Spa High Spa Low Pool High Pool Low Control Parameter Unaffected, Pool only, Spa only, or Spillover Unaffected, Off, On, High speed, or Low speed Unaffected, Off, or On Unaffected, Off, On, 100%, 80%, 60%, 40%, or 20% Unaffected, Off, On, High speed, or Low speed Unaffected, Off, or On Unaffected, Off, On, 100%, 80%, 60%, 40%, or 20% Unaffected, Off, or On Unaffected, Off, or On Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, 65º-104ºF Unaffected, Off, On Unaffected, 20% to Highest Speed Unaffected, Lowest Speed to 50% Unaffected, 20% to Highest Speed Unaffected, Lowest Speed to 50% 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Flow Switch
The flow switch cable plugs into the Aqua Plus 16v Control Center as shown in the diagram on page 12.
Ensure
that the connector catch “snaps” in order to provide a reliable connection.
Turbo Cell
The Turbo Cell should be plugged in after the Aqua Plus 16v cover panel is put back in place.
Refer to page 12 for
the location of the connector.
External Input Interlock
The External Input Interlock provides a means to force the filter pump or an Aux output off when certain conditions
exists.
A normally open or normally closed on/off external device must be connected to the Aqua Plus 16v as
shown below.
After properly configuring the Aqua Plus 16v (see Configuration), the filter pump and/or desired
Aux will be forced off when the device is active.
SPST External Switch
(either Normally Open or Normally Closed)
Hayward Aqua Rite Chlorinator
The Aqua Plus 16v can control one or more Hayward Aqua Rite chlorinators when additional sanitizing capacity is
required.
A 4 wire connection is used to communicate to the Aqua Rite and can be wired up to 500' apart.
Any
outdoor rated 4 conductor cable can be used.
Refer to the wiring diagrams below for proper wiring connection to
the Aqua Rite. NOTE: There must be only 1 "primary" unit.
All other Aqua Rite units must be configured as
"secondary".
5.
Configuration Setup
After plumbing and wiring are complete, the Aqua Plus 16v MUST BE CONFIGURED before attempting to
operate.
Configuration information is entered at the keypad and “tells” the Aqua Plus 16v what equipment is
connected and how each should be controlled.
Group Function
The Aqua Plus 16v offers the ability to assign a Group function to a particular button.
Instead of a button control-
ling one particular function, the button can be programmed to initiate a sequence of commands that are pro-
grammed in the Configuration Menu.
For example, instead of the Lights button turning on and off the pool light
only, the button can be programmed to turn on the pool light, turn on the bug light, turn off the pool cleaner, turn on
and dim the patio lights, turn on the music, etc. all at the same time.
This convenient feature is offered on all Aux
buttons, both Valve buttons and the Lights button. The Aqua Plus 16v can be programmed to control up to four
groups. Refer to this section when programming Group commands.
Before assigning and configuring all the desired functions and their control parameters, the group itself must be
configured.
The options for controlling groups are Manual On/Off, Countdown Timer, and Timeclock. The group
will turn on and off based on this selection.
When setting up a Group function in the Configuration Menu, the first menu allows you to select the control
parameter (how the group is activated and de-activated) and the second menu allows you to select which Aqua
Plus 16v functions are to be controlled in the group.
A table of functions and their corresponding control parameters are listed below.
22
21
Aqua Plus 16v
Aqua Rite
(Primary)
Aqua Rite
(Secondary)
Additional
Aqua Rite(s)
(if required)
Jumper Removed
For Secondary(s)
Jumper Installed
For Primary
(Factory Default)
1
2
3
4
GREEN
YELLOW
BLACK
RED
NOTE: Primary/Secondary jumper is located underneath small circuit board.
4
4
3
3
2
2
1
1
GRN
GRN
BLK
BLK
YEL
YEL
RED
RED
Aqua Plus
Aqua Rite
green
yellow
black
red
Pool/Spa
Unaffected, Pool only, Spa only, or Spillover
Pool Filter
Unaffected, Off, On, High speed, or Low speed
or
Function
Control Parameter
Lights
Unaffected, Off, or On
Lights
Unaffected, Off, On, 100%, 80%, 60%, 40%, or 20%
Spa Filter
Unaffected, Off, On, High speed, or Low speed
Aux1-14
Unaffected, Off,
On
Aux1-14
Unaffected, Off, On, 100%, 80%, 60%, 40%, or 20%
Valve3
Unaffected, Off, or On
Valve4
Unaffected, Off, or On
Spa Htr1 Set
Unaffected, Off, 65º-104ºF
Pool Htr1 Set
Unaffected, Off, 65º-104ºF
Spa Htr2 Set
Unaffected, Off, 65º-104ºF
Pool Htr2 Set
Unaffected, Off, 65º-104ºF
Spa Solar Set
Unaffected, Off, 65º-104ºF
Pool Solar Set
Unaffected, Off, 65º-104ºF
SuperChlr
Unaffected, Off, On
Spa High
Unaffected, 20% to Highest Speed
Spa Low
Unaffected, Lowest Speed to 50%
Pool High
Unaffected, 20% to Highest Speed
Pool Low
Unaffected, Lowest Speed to 50%
(standard relay)
(dimmer relay)
(s
(dimmer relay)
tandard relay)