Hayward AquaTrol Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL
Hayward AquaTrol Manual
View all Hayward AquaTrol manuals
Add to My Manuals
Save this manual to your list of manuals |
Hayward AquaTrol manual content summary:
- Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 1
Aqua Trol® Above Ground Pool Chlorine Generator Operation and Installation Manual AQ-TROL-RJ AQ-TROL-RJ-TL AQ-TROL-HP AQ-TROL-HP-TL www.haywardnet.com - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 2
: • READ AND FOLLOW ALL INSTRUCTIONS • Disconnect all AC power during installation. • Warning - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. • A green colored terminal marked "Earth Ground" is located inside the wiring - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 3
Table of Contents OPERATION The Aqua Trol 1 Water Chemistry 1 Controls 6 Maintenance 8 . INSTALLATION Mounting 9 Plumbing 10 Wiring 11 TROUBLESHOOTING Troubleshooting 13 WARRANTY Warranty 15 - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 4
The Aqua Trol® is an automatic chlorine generation system with a built-in filter pump timer designed specifically for above ground pools. The operation requires a low concentration of salt (sodium chloride) in the pool water at levels low enough that it normally will not be tasted. The Aqua Trol - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 5
levels in order to prevent corrosion or scaling and to ensure maximum enjoyment of the pool. Test your water periodically. Your local pool store can provide you with the chemicals and procedures to adjust the water chemistry. Be sure to tell the pool store that you are using an Aqua Trol chlorine - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 6
-3400 ppm (parts per million) with 3200 ppm being optimal. If the level is low, determine the number of gallons in the pool and add salt according to the chart on page 4. A low salt level will reduce the efficiency of the Aqua Trol® and result in low chlorine production. A high salt level can cause - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 7
Pool/Spa water Current salt level 69) (91) (114) (136) (159) (182) (205) 400 140 187 233 280 327 373 420 (64) (85) (106) (127) (148) (170) (191) 600 130 173 217 260 303 347 390 (59) (79 187 210 (32) (42) (53) (64) (74) (85) (95) 2000 60 80 100 120 140 160 180 (27) (36) (45) (55) (64 - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 8
when checking salt. These levels will most likely decline together. Use the chart below to determine how much stabilizer must be added to raise the level to 80 ppm. POUNDS and (Kg) OF STABILIZER (CYANURIC ACID) NEEDED FOR 80 PPM Gallons and (Liters) of Pool/Spa water Current Stabilizer Level (ppm - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 9
the electrolytic cell. In this position there is no chlorine generation. NOTE: To service any of the pool equipment or the Aqua Trol, turn the power off at the circuit breaker. "Desired Level %" adjustment knob This setting is used to control the amount of chlorine the Aqua Trol generates. Raise - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 10
reduced and the Aqua Trol has stopped producing chlorine. Inspect, clean or replace if necessary. Salt Display The Salt Display shows the current salt concentration of the pool water. Readings are in ppm (parts per million). Refer to the Water Chemistry section for recommended salt levels as well as - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 11
then rinse with a high pressure garden hose. If any deposits are still visible, repeat soaking and rinsing. Replace cell and inspect again periodically. Winterizing The Aqua Trol electrolytic cell and flow detection switch will be damaged by freezing water just as your pool plumbing would. In areas - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 12
Aqua Trol. NOTE: If the pool does not have new water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of non-copper based algaecide to the pool, per manufacturers instructions. This ensures a quick, troublefree transfer to the Aqua Trol system. Mounting the Aqua Trol Control The Aqua - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 13
cell and flow switch (not used on -RJ systems) are plumbed in the return line to the pool. Install after (downstream) all the pool equipment (filter, heater, solar, etc.). The kit included in the Aqua Trol provides the necessary plumbing components for either 2" (51mm) rigid PVC piping installation - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 14
lock receptacle wired to a GFCI circuit breaker. For Canadian installations: Connect to a circuit protected by a Class-A ground fault interruptor. See diagram below. NEUTRAL GROUND SUBPANEL GFCI OUTLET Aqua Trol AQUA TROL (AQ-TROL-XX) BONDING LOOP PUMP GFCI CIRCUIT BREAKER TWIST-LOCK PLUGS - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 15
the Aqua Trol electronics unit. Note that return jet units (-RJ option) will NOT have a flow switch. See diagram below. Phone jack to flow switch Cutout for cell cable to GF1CI2NI0PreVUcATeCpPtlOaincWelecE/obRrrdeaker1O20UtoTVPApUoCoTrlePpcuOemWptpaEcRle Bonding lug to pool bonding system 12 - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 16
" position, and none of the red fault LEDs are illuminated. 4. "Generating" LED flashing The temperature of the pool water is too high or low to operate. You can override this by switching the main switch to SUPER CHLORINATE. The Aqua Trol will run at maximum output for the remainder of the - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 17
Salt level too low (below 2500 ppm, Low Salt LED on). - Salt level too high (High Salt LED on). - Very warm pools increase chlorine demand--increase Desired Level % or filter run time. - Cold water (below 50F) causes Aqua Trol to stop generating (Generating LED flashing). - Excessive scaling on cell - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 18
its Aqua Trol chlorination products to be free of defects in materials and workmanship, under normal use and service for a period of one (1) year. These warranties are applicable from the initial date of installation on private residential swimming pools in the US and Canada. Hayward/Goldline - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 19
16 - Hayward AquaTrol | Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 20
add water to decrease. Electrolytic Cell inspect & clean Refer to section in manual. Questions? Refer to www.goldlinecontrols.com for latest manual revisions, additional information and helpful service. QUARTERLY 620 Division St. Elizabeth, NJ 07207 092016K RevL Copyright © 2010 Hayward Inc.
Above Ground
Pool Chlorine Generator
Operation and Installation
Manual
AQ-TROL-RJ
AQ-TROL-RJ-TL
AQ-TROL-HP
AQ-TROL-HP-TL
www.haywardnet.com
Aqua Trol
®