Hayward AquaTrol Models: AQ-TROL-HP AQ-TROL-HP-TL AQ-TROL-RJ and AQ-TROL-RJ-TL - Page 14

Wiring - aqua trol for above ground pools

Page 14 highlights

Wiring Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local and NEC/CEC electrical codes. The Aqua Trol has been designed to easily wire into typical above ground pool systems. To provide safe operation, the Aqua Trol must be properly grounded and bonded. Input Power Models with the standard 120 VAC line cord should be plugged into a GFCI receptacle. Twist lock models should be plugged into a twist lock receptacle wired to a GFCI circuit breaker. For Canadian installations: Connect to a circuit protected by a Class-A ground fault interruptor. See diagram below. NEUTRAL GROUND SUBPANEL GFCI OUTLET Aqua Trol AQUA TROL (AQ-TROL-XX) BONDING LOOP PUMP GFCI CIRCUIT BREAKER TWIST-LOCK PLUGS (L520) Aqua Trol NEUTRAL GROUND SUBPANEL TWIST-LOCK OUTLET (L520) AQUA TROL (AQ-TROL-XX-TL) BONDING LOOP PUMP 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

11
Wiring
Power must be shut off at the circuit breaker before performing any wiring.
Be sure
to follow Local and NEC/CEC electrical codes.
The Aqua Trol has been designed to
easily wire into typical above ground pool systems.
To provide safe operation, the
Aqua Trol must be properly grounded and bonded.
Input Power
Models with the standard 120 VAC line cord should be plugged into a GFCI recep-
tacle.
Twist lock models should be plugged into a twist lock receptacle wired to a
GFCI circuit breaker.
For Canadian installations:
Connect to a circuit protected by
a Class-A ground fault interruptor.
See diagram below.
SUBPANEL
SUBPANEL
GROUND
GROUND
NEUTRAL
NEUTRAL
GFCI
OUTLET
TWIST-LOCK
OUTLET (L520)
TWIST-LOCK
PLUGS (L520)
BONDING
LOOP
BONDING
LOOP
PUMP
PUMP
AQUA TROL
(AQ-TROL-XX)
AQUA TROL
(AQ-TROL-XX-TL)
GFCI CIRCUIT
BREAKER
Aqua Trol
Aqua Trol