Plumbing - rj

Page 13 highlights

Plumbing The cell and flow switch (not used on -RJ systems) are plumbed in the return line to the pool. Install after (downstream) all the pool equipment (filter, heater, solar, etc.). The kit included in the Aqua Trol provides the necessary plumbing components for either 2" (51mm) rigid PVC piping installation or 1½ - 1¼" (38-32mm) flexible hose installation. An overview of the Aqua Trol system with the hose/pipe installation (HP) is shown on the previous page, see below for detail on the return jet mounting. Hose/Pipe installations (-HP option): Install the cell and flow switch as shown in the diagrams below. Always make sure that the flow switch is downstream from the cell. When using the hose adaptors, remove the o-ring from the pipe union tailpiece and install them in the hose tailpieces. Tighten all union nuts BY HAND for a watertight seal. FROM PUMP Hose Assembly TO POOL FROM PUMP Pipe Assembly TO POOL Return Jet installation (-RJ option): Unscrew the the hose adaptor from the pool return jet fitting and, in its place, screw in the right-angle cell mounting adaptor. Note that this installation does NOT require a flow switch--however it is very important that the cell be mounted vertically directly below the return jet in order to allow the gases produced in the cell to naturally dissipate in the pool. Attach the cell to the union and then use the fittings supplied to attach the lower end of the cell to either the hose or rigid PVC pipe coming from the pools filtration system. Tighten all union nuts BY HAND for a watertight seal. RETURN JET FROM FILTER 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Plumbing
The cell and
flow switch (not used on -RJ systems) are plumbed in the return line to
the pool.
Install
after (downstream) all the pool equipment (filter, heater, solar, etc.).
The kit included in the Aqua Trol provides the necessary plumbing components for
either 2" (51mm) rigid PVC piping installation or 1½ - 1¼" (38-32mm) flexible hose
installation.
An overview of the Aqua Trol system with the hose/pipe installation (-
HP) is shown on the previous page, see below for detail on the return jet mounting.
Hose/Pipe installations (-HP option):
Install the cell and flow switch as shown in
the diagrams below.
Always make sure that the flow switch is
downstream from the
cell.
When using the hose adaptors, remove the o-ring from the pipe union tail-
piece and install them in the hose tailpieces.
Tighten all union nuts
BY HAND
for
a watertight seal.
Return Jet installation (-RJ option):
Unscrew the the hose adaptor from the pool
return jet fitting and, in its place, screw in the right-angle cell mounting adaptor.
Note that this installation does NOT require a flow switch--however it is very
important that the cell be mounted vertically directly below the return jet in order to
allow the gases produced in the cell to naturally dissipate in the pool.
Attach the
cell to the union and then use the fittings supplied to attach
the lower end of the
cell to either the hose or rigid PVC pipe coming from the pools filtration system.
Tighten all union nuts
BY HAND
for a watertight seal.
FROM PUMP
FROM PUMP
TO POOL
TO POOL
Hose Assembly
Pipe Assembly
10
FROM
FILTER
RETURN
JET