Hayward Pro Logic® Models: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Installatio - Page 28

Chemistry Configuration Wizard, Pool/Spa Setup, Heaters, Spa CountDn, Spa Spillover

Page 28 highlights

Chemistry Config. Wizard + to enter Press to access Chemistry Config. Wizard Move to previous/next menu item Chemistry Configuration Wizard Requires use of the optional AQL-CHEM Sensing Kit. Following the steps of the Chemistry Config. Wizard will set up the AQL-CHEM to sense ORP and pH levels and, if the chlorination function is used, can configure the Pro Logic to generate the correct amount of chlorine to properly sanitize the pool. Refer to the AQL-CHEM manual for more detailed information. Pool/Spa Config. + to view/change Push to access Pool/Spa options Move to previous/next configuration menu Pool/Spa Setup Pool and Spa-Std Rotates between Pool and Spa-Std (default), Pool and Spa-Dual, Pool Only, and Spa Only options Move to next menu item if "Pool and Spa-Dual" is selected Heaters Toggle between Htr1=Spa, Htr2=Pool (default) and Shared Heaters Htr1=Spa,Htr2=Pool Move to next menu item if "Pool and Spa-Std" is selected Spa - CountDn Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00)) 00:30 Move to next menu item if "Pool and Spa-Std or Dual" is selected Spa Spillover Toggle between Enabled and Disabled (default) Spa Spillover Enabled Move to next menu item or previous/next configuration menu if "Pool and Spa-Std or Dual" is selected and if "Spa Spillover" is enabled Filter Operation Toggle between Pool Only (default) and Spa Spillover options Spa Spillover Move to previous/next configuration menu if "Pool Only" or "Spa Only" is selected V1=Aux1, V2=Aux2 Toggle between Enabled and Disabled (default) Disabled Move to previous/next configuration menu if "Pool and Spa-Std" is selected Filter Off Valve Toggle between Enabled (default) and Disabled Change: Enabled Move to previous/next configuration menu Pool/Spa Setup If "Pool Only" or "Spa Only" are selected, then the pool/spa valves are not needed and pushing the POOL/SPA button on the display/keypad will have no effect. If "Pool and Spa-Std" is selected, then the pool/spa suction and return valve actuators should be connected to the Pro Logic. Pressing the POOL/SPA button on the display/keypad will allow the homeowner to alternate between pool and spa operation. If "Pool and Spa-Dual" is selected, then only the Pool/Spa return valve actuator should be connected to the Pro Logic. Heaters This menu will only appear if Pool/Spa setup is set to "Pool and Spa-Dual". This allows the heater(s) to either be shared between the pool and spa ("Shared" selected) or for Heater1 to be dedicated to the spa and Heater2 to be dedicated to the pool ("Htr1=Spa, Htr2=Pool" selected). Spa CountDn This menu will appear only if Pool/Spa Setup is set to "Pool and Spa-Std". This setting is the time, after you manually switch the Pool/Spa valves to "Spa Only", until the Pro Logic automatically returns the valves to their previous positions. It is programmed in increments of 5 minutes, from "Manual On/Off" (0 minutes) to "21:00" (21 hours). The filter is forced on during this time period. Spa Spillover When spa spillover is "Enabled" and "Pool and Spa-Std", the homeowner will be able to rotate through "Pool Only" (both suction and return valves switched to pool), "Spa Only" (both suction and return valves switched to spa) and "Spillover" (suction valve switched to pool and return valve 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

25
Chemistry Config.
Wizard + to enter
Press to access Chemistry Config. Wizard
Move to previous/next menu item
Chemistry Configuration Wizard
Requires use of the optional AQL-CHEM Sensing Kit.
Following the steps of the Chemistry Config.
Wizard will set up the AQL-CHEM to sense ORP and pH levels and, if the chlorination function is
used, can configure the Pro Logic to generate the correct amount of chlorine to properly sanitize the
pool. Refer to the AQL-CHEM manual for more detailed information.
Pool/Spa Config.
+ to view/change
Pool/Spa Setup
Pool and Spa-Std
Spa Spillover
Enabled
Heaters
Htr1=Spa,Htr2=Pool
Filter Operation
Spa Spillover
Push to access Pool/Spa options
Rotates between Pool and Spa-Std
, Pool and Spa-Dual,
Pool Only, and Spa Only options
(default)
Toggle between Enabled and Disabled
Spa Spillover
(default)
Toggle between Htr1=Spa, Htr2=Pool (default) and Shared Heaters
Toggle between Pool Only
and Spa Spillover
options
(default)
Move to previous/next configuration menu
Move to next menu item
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to previous/next configuration menu
if “Pool and Spa-Std or Dual” is
selected and if “Spa Spillover” is enabled
Spa - CountDn
00:30
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00))
Move to next menu item
if “Pool and Spa-Std” is selected
if “Pool and Spa-Dual” is selected
if “Pool and Spa-Std or Dual” is selected
V1=Aux1, V2=Aux2
Disabled
Toggle between Enabled and Disabled (default)
if “Pool Only” or “Spa Only” is selected
Move to previous/next configuration menu
Filter Off Valve
Change: Enabled
Toggle between Enabled
and Disabled
(default)
if “Pool and Spa-Std” is selected
Move to previous/next configuration menu
Pool/Spa Setup
If “Pool Only” or “Spa Only” are selected, then the pool/spa valves are not needed and pushing the
POOL/SPA button on the display/keypad will have no effect.
If “Pool and Spa-Std” is selected, then
the pool/spa suction and return valve actuators should be connected to the Pro Logic.
Pressing the
POOL/SPA button on the display/keypad will allow the homeowner to alternate between pool and spa
operation.
If “Pool and Spa-Dual” is selected, then only the Pool/Spa return valve actuator should be
connected to the Pro Logic.
Heaters
This menu will only appear if Pool/Spa setup is set to “Pool and Spa-Dual”.
This allows the heater(s)
to either be shared
between the pool and spa (“Shared” selected) or for Heater1 to be dedicated to the
spa and Heater2 to be dedicated to the pool (“Htr1=Spa, Htr2=Pool” selected).
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to “Pool and Spa-Std”.
This setting is the time,
after you manually switch the Pool/Spa valves to “Spa Only”, until the Pro Logic automatically
returns the valves to their previous positions. It is programmed in increments of 5 minutes, from
“Manual On/Off” (0 minutes) to
“21:00” (21 hours).
The filter is forced on during this time period.
Spa Spillover
When spa spillover is “Enabled” and “Pool and Spa-Std”, the homeowner will be able to rotate
through “Pool Only” (both suction and return valves switched to pool), “Spa Only” (both suction and
return valves switched to spa) and “Spillover” (suction valve switched to pool and return valve