HP 1606 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01, July 2009) - Page 100
AG-1019, or some new N_Port/F_Port has come online.
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
2 AG-1019 Recommended Action Run the switchShow command to display the status of all ports in the system. Run the portCfgShow command to display a list of ports currently configured as N_Ports. Ensure that the host is connected to an F_port. Severity ERROR AG-1019 Message , [AG-1019], ,, WARNING, , Unable to failover N_Port . No other N Port in port group: is online. Probable Cause Indicates that failover across port groups is not supported. Recommended Check whether or not an alternate N_Port is configured in this port group. Action Severity WARNING AG-1020 Message , [AG-1020], ,, INFO, , F_Ports to N_Ports route/mapping has been changed. Probable Cause Indicates that F_Port -to-N_Port mapping has been changed because the switch has come online or some new N_Port/F_Port has come online. Recommended Run the ag --mapshow command to display the updated F_Port-to-N_Port mapping. Action Severity INFO AG-1021 Message , [AG-1021], ,, WARNING, , Unable to do Preferred-Failover of F_Port . Failover across different fabric is not supported. Probable Cause Indicates that the failover does not get blocked between two fabrics, although it is not a supported configuration. Recommended Action Change the preferred N_Port settings for this F_Port using the ag --prefset command. Choose the preferred N_Port such that it is in the same fabric as the primary N_Port of this F_Port. Use the ag --show command to check the fabric connectivity of N_Ports. Severity WARNING 30 Fabric OS Message Reference 53-1001338-01