HP 1606 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01, July 2009) - Page 225
EM-1048, EM-1049, EM-1050
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 225 highlights
22 EM-1048 Probable Cause Indicates that the control processor (CP) is no longer faulted. This message usually follows EM-1033. The new standby CP is in the process of rebooting and has turned off the CP_ERR signal. Recommended No action is required. Action Severity INFO EM-1048 Message , [EM-1048], ,, INFO, , I2C access recovered: state Probable Cause Indicates that the I2C bus problems have been resolved and I2C access to the field-replaceable unit (FRU) has become available again. Recommended The EM-1029 error can be a transitory error; if the problem resolves, the EM-1048 message is Action displayed. Severity INFO EM-1049 Message , [EM-1049], ,, INFO, , FRU insertion detected. Probable Cause Indicates that a field-replaceable unit (FRU) of the type and location specified by the FRU ID was detected as having been inserted into the chassis. Recommended No action is required. Action Severity INFO EM-1050 Message , [EM-1050], ,, INFO, , FRU removal detected. Probable Cause Indicates that a field-replaceable unit (FRU) of the specified type and location was removed from the chassis. Recommended Verify that the FRU was intended to be removed. Replace the FRU as soon as possible. Action Severity INFO Fabric OS Message Reference 155 53-1001338-01