HP 2000fc HP StorageWorks 2000 Family Modular Smart Array chassis and midplane
HP 2000fc Manual
View all HP 2000fc manuals
Add to My Manuals
Save this manual to your list of manuals |
HP 2000fc manual content summary:
- HP 2000fc | HP StorageWorks 2000 Family Modular Smart Array chassis and midplane - Page 1
installing them into the replacement chassis of an HP StorageWorks 2000 Family Modular Smart Array. NOTE: Make sure you obtain the latest version of these instructions from http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Support. Before you begin • Turn the power-and - HP 2000fc | HP StorageWorks 2000 Family Modular Smart Array chassis and midplane - Page 2
1. Press and slide the release latch button to the right to disengage the latch. Removing power-and-cooling modules 1. Turn the thumbscrew (1) until it is disengaged from the power-and-cooling module. 2. Rotate the latch (2) downward to disconnect the power module from the internal connector, and - HP 2000fc | HP StorageWorks 2000 Family Modular Smart Array chassis and midplane - Page 3
until the screws disengage from the I/O module. 12 1 2 3. Pull outward on the latches to slide the module out of the enclosure. Service 1 Latch 2 Thumbscrew 2. Press both latches downward to disconnect the I/O module from the midplane. Installing controller modules 1. Loosen the controller - HP 2000fc | HP StorageWorks 2000 Family Modular Smart Array chassis and midplane - Page 4
(1). 3. Press the latches upward to engage the I/O module (2); turn the thumbscrews finger-tight. Service Service 1 2 2 Verifying component installation • Reconnect cables and power on the system and associated data online. Additional information See the MSA web site: http://www.hp.com/go/msa. Page 4
Page 1
481596-001
About this document
The chassis field replacement unit (FRU) replaces a chassis that has
been damaged or whose midplane has been damaged. To make a
fully functional chassis, you must install the following components
from the replaced chassis:
•
Drive modules and air management modules
•
Two power-and-cooling modules
•
One or two controller modules (for a controller enclosure)
•
One or two I/O modules (for a drive enclosure)
This document details procedures for removing drive modules/air
management modules, power-and cooling-modules, controller
modules, and I/O modules from the failed chassis and installing
them into the replacement chassis of an HP StorageWorks 2000
Family Modular Smart Array.
NOTE:
Make sure you obtain the latest version of these
instructions from
. Select MSA SAN
Arrays, select your product, and go to Support.
Before you begin
•
Turn the power-and-cooling supply modules off and disconnect
the power cables.
•
Disconnect and label all cables.
CAUTION:
Parts can be damaged by electrostatic discharge.
Use proper anti-static protection:
•
Keep the replacement component in the ESD bag until needed.
•
Wear an ESD wrist strap grounded to an unpainted surface of
the chassis.
•
If an ESD wrist strap is unavailable, touch an unpainted surface
of the chassis before handling the component.
•
Never touch connector pins.
Removing drive modules
NOTE:
Air management modules are removed and installed
using the same procedure as removing and installing drive modules.
Printed on at least 50% total recycled fiber with at least 10%
post-consumer paper
© Copyright 2008 Hewlett-Packard Development Company, L.P.
First edition: March 2008
Product names mentioned herein may be trademarks of their
respective companies as reflected by an associated footnote. The
information in this document is subject to change without notice.
Printed in the US.
www.hp.com
HP StorageWorks
2000 Family Modular Smart
Array
chassis and midplane
replacement instructions