HP 2000fc HP StorageWorks 2000 Modular Smart Array Controller Module Replaceme
HP 2000fc Manual
View all HP 2000fc manuals
Add to My Manuals
Save this manual to your list of manuals |
HP 2000fc manual content summary:
- HP 2000fc | HP StorageWorks 2000 Modular Smart Array Controller Module Replaceme - Page 1
HP website at http:// www.hp.com/support/manuals. Under the storage banner, navigate to the page for your storage enclosure. This document details procedures for replacing a failed controller module in an HP StorageWorks other controller as detailed in these instructions. *488318-003* IMPORTANT: - HP 2000fc | HP StorageWorks 2000 Modular Smart Array Controller Module Replaceme - Page 2
Use the following methods to verify failure: • Check the Fault/Service Required LED (back): • Amber = Fault condition • Check HP recommends enabling this feature. To see the current Partner Firmware Upgrade setting, select Monitor > Status > Advanced Settings > Misc Configuration. If Partner Firmware - HP 2000fc | HP StorageWorks 2000 Modular Smart Array Controller Module Replaceme - Page 3
firmware versions differ between the two controllers, Partner Firmware Upgrade feature brings the older firmware to the later firmware indicating that the controller has completed initializing and is online. If the Fault/Service Required LED is amber, the module has not gone online and likely failed - HP 2000fc | HP StorageWorks 2000 Modular Smart Array Controller Module Replaceme - Page 4
, HP specifies whether the failed component must be returned. Follow the provided instructions. Additional information HP P2000/MSA Disk Arrays: http://www.hp.com/go/msa HP storage: http://www.hp.com/storage HP support: http://www.hp.com/support HP documents: http://www.hp.com/support/manuals Page
HP StorageWorks
2000 Modular Smart Array
Controller Module Replacement
Instructions
This document details procedures for replacing a failed
controller module in an HP StorageWorks 2012/2212
Modular Smart Array (MSA2000).
© Copyright 2008, 2010 Hewlett-Packard Development Company,
L.P.
Third edition: March 2010
The information in this document is subject to change without notice.
Printed in China.
www.hp.com
*488318-003*
About this document
•
Illustrations in this document may show a controller module with a
connection interface that differs from your controller module. Replace-
ment procedures are the same for all MSA2000 controller modules.
•
The Storage Management Utility (SMU) and the Command Line Inter-
face (CLI) can be used to manage MSA2000
–
family enclosures.
Tasks in this document demonstrate using the SMU.
•
For the latest product documentation, see the HP website at
h
t
tp://
w
w
w
.hp
.co
m/su
ppo
r
t/man
uals
. Under the storage banner, navigate
to the page for your storage enclosure.
Before you begin
Observe the following:
CAUTION:
•
When replacing a controller in an operational controller en-
closure, ensure that less than 10 seconds elapse between in-
serting the controller into a slot and fully latching it in place.
Failing to do so might cause the controller to fail. If it is not
latched within 10 seconds, remove the controller from the slot
and repeat the process.
•
Removing a module from an operational enclosure significantly
changes air flow within the enclosure. Openings must be
populated for the enclosure to cool properly. Leave modules
in the enclosure until a replacement is available.
•
Parts can be damaged by electrostatic discharge; use proper
anti-static protection. Keep parts in electrostatic containers
until needed and ensure you are properly grounded when
touching static-sensitive components.
IMPORTANT:
When replacing both controllers in an operational enclosure,
do as follows:
1.
Replace one controller as detailed in these instructions.
2.
Wait 30 minutes. This pause ensures that the two controllers
and their ownership of the vdisks have enough time to fully
stabilize.
3.
Examine system status and event logs to ensure that the system
is stable.
4.
Replace the other controller as detailed in these instructions.
IMPORTANT:
When two controllers are installed in an enclosure, they must
be the same model. Mixing controller types in the same
enclosure is not supported.
Page 1