HP 2000sa HP StorageWorks MSA2000 G2 SMI-S Proxy Provider User Guide (573100-0 - Page 13

Linux, MSA2000 G2 SMI-S Proxy Provider User Guide

Page 13 highlights

7. Click View Logs to see the installation logs. For additional log files see: • /cpqsystem/log/Installbat.log - log of scripts run during installation • /cpqsystem/log/msiexec_PSM.log - log of PSM msi installation • /cpqsystem/log/cp009873.log - log of SmartComponent installation NOTE: For a typical installation, Open Pegasus and Proxy Providers are installed into the HPMSAPegasus folder under the Windows system drive as shown in Figure 4, page 13. The Proxy Settings Manager is installed into Program Files or Program Files x64. Figure 4 Pegasus installation directory . To uninstall the Proxy Provider: 1. Navigate to the Control Panel Add or Remove Programs window and uninstall the components in the sequence listed. 2. To remove PSM, select HP StorageWorks MSA2000 SMI-S Proxy Settings Manager and then click Remove. 3. To remove the Proxy Provider, select HP StorageWorks MSA2000 Proxy Provider for Windows and then click Remove. 4. To remove Pegasus, select Open Pegasus and then click Remove. Linux The Linux package is bundled as a .tgz file, which includes the SMI-S Proxy Providers and PSM. This version of Proxy providers has the following constraints defined: • It has dependency on tog-pegasus rpm. This is required in SLES also. It does not use open-wbem in SLES. Requires tog-pegasus version 2.7.0 or later. MSA2000 G2 SMI-S Proxy Provider User Guide 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

7.
Click
View Logs
to see the installation logs. For additional log files see:
<systemdrive>/cpqsystem/log/Installbat.log
log of scripts run during install-
ation
<systemdrive>/cpqsystem/log/msiexec_PSM.log
log of PSM msi installation
<systemdrive>/cpqsystem/log/cp009873.log
log of SmartComponent installation
NOTE:
For a typical installation, Open Pegasus and Proxy Providers are installed into the HPMSAPegasus folder
under the Windows system drive as shown in
Figure 4
, page 13. The Proxy Settings Manager is installed
into
Program Files
or
Program Files x64
.
Figure 4 Pegasus installation directory
.
To uninstall the Proxy Provider:
1.
Navigate to the Control Panel
Add or Remove Programs
window and uninstall the components
in the sequence listed.
2.
To remove PSM, select
HP StorageWorks MSA2000 SMI-S Proxy Settings Manager
and then click
Remove
.
3.
To remove the Proxy Provider, select
HP StorageWorks MSA2000 Proxy Provider for Windows
and then click
Remove
.
4.
To remove Pegasus, select
Open Pegasus
and then click
Remove
.
Linux
The Linux package is bundled as a .tgz file, which includes the SMI-S Proxy Providers and PSM.
This version of Proxy providers has the following constraints defined:
It has dependency on tog-pegasus rpm. This is required in SLES also. It does not use open-wbem
in SLES. Requires tog-pegasus version 2.7.0 or later.
MSA2000 G2 SMI-S Proxy Provider User Guide
13