HP 381513-B21 HP Smart Array P800 Controller for ProLiant Servers User Guide - Page 6

For more information about the controller features and specifications - internal storage

Page 6 highlights

Temperature range Relative humidity (noncondensing) RAID levels supported Type of edge connector PCIe transfer rate Number of SAS ports Maximum number of physical drives (using all four ports) Maximum number of logical drives Maximum size of a logical drive SAS transfer rate Spare battery part number Time required to recharge battery Duration of battery backup Battery life expectancy Cache size Operating, 10° to 55°C (50° to 131°F) Storage, -30° to 60°C (-22° to 140°F) Operating, 10% to 90% Storage, 5% to 90% 0, 1, 1+0, and 5; also 6 if the batteries are used PCIe x8 Up to 2 GB/s in each direction Two internal, two external; each port has four 1x links 108 (8 can be connected internally, and a further 100 can be connected externally by using expanders) 32 More than 2 TB Up to 1.2 GB/s per port in each direction 398648-001 From 15 minutes to 2 hours, depending on the initial battery charge level More than 2 days if the batteries are fully charged and less than 3 years old More than 3 years 512 MB (48 MB is used by the onboard processor) For more information about the controller features and specifications, and for information about system requirements, refer to the HP website (http://www.hp.com/products/smartarray). Hardware features 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

Hardware features 6
Temperature range
Operating, 10° to 55°C (50° to 131°F)
Storage, -30° to 60°C (-22° to 140°F)
Relative humidity
(noncondensing)
Operating, 10% to 90%
Storage, 5% to 90%
RAID levels supported
0, 1, 1+0, and 5; also 6 if the batteries are used
Type of edge connector
PCIe x8
PCIe transfer rate
Up to 2 GB/s in each direction
Number of SAS ports
Two internal, two external; each port has four 1x links
Maximum number of physical
drives (using all four ports)
108 (8 can be connected internally, and a further 100 can be
connected externally by using expanders)
Maximum number of logical
drives
32
Maximum size of a logical drive
More than 2 TB
SAS transfer rate
Up to 1.2 GB/s per port in each direction
Spare battery part number
398648-001
Time required to recharge
battery
From 15 minutes to 2 hours, depending on the initial battery charge
level
Duration of battery backup
More than 2 days if the batteries are fully charged and less than 3
years old
Battery life expectancy
More than 3 years
Cache size
512 MB (48 MB is used by the onboard processor)