HP 3PAR StoreServ 7200 2-node HP 3PAR CIM API Programming Reference (OS 3.1.2 - Page 209
For modifying an SPC, the HP 3PAR Storage System supports only, of LUNames. LUNames
View all HP 3PAR StoreServ 7200 2-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 209 highlights
"For creating an SPC, all parameters, except ProtocolControllers, " "MUST be specified since SPCAllowsNoLUs, SPCAllowsNoTargets and " "SPCAllowsNoInitiators properties are all false, and " "ClientSelectableDeviceNumbers property is true, for a HP 3PAR " "Storage System. \n" "\n" "The LUNames, DeviceNumbers, and DeviceAccesses parameters " "are mutually indexed arrays - any element in DeviceNumbers " "or DeviceAccesses will set a property relative to the " "LogicalDevice instance named in the corresponding element " "of LUNames. LUNames, DeviceNumbers and DeviceAccesses MUST " "have the same number of elements. If these conditions are " "not met, the instrumentation MUST return a 'Invalid Parameter' " "status or a CIM_Error. \n" "\n" "For modifying an SPC, the HP 3PAR Storage System supports only " "the Add LUs to a view use case." "Add LUs to a view requires that the LUNames and DeviceNumbers " "parameters not be null and that the InitiatorIDs and TargetPortIDs " "parameters be null. \n" "\n" "The relevant rules of SCSI semantics are: \n" "- an SPC MAY NOT be exposed through a particular " "host/target port pair that is in use by another SPC. (In " "other words, an SPC and its associated logical units and " "ports together correspond to the logical unit inventory " "provided by SCSI REPORT LUNS and INQUIRY commands) \n" "- each LogicalDevice associated to an SPC MUST have a " "unique ProtocolControllerForUnit DeviceNumber (logical unit " "number) \n" "The instrumentation MUST report an error if the client " "request would violate one of these rules. \n" "\n" "If the instrumentation provides PrivilegeManagementService, " "the results of setting DeviceAccesses MUST be synchronized " "with PrivilegeManagementService as described in the " "ProtocolControllerForUnit DeviceAccess description."), ValueMap { "0", "1", "2", "3", "4", "5", "6..4095", "4096", "4097", "4098", "4099", "4100", "4101", "4102", "4103", "4104..32767", "32768..65535" }, Values { "Success", "Not Supported", "Unspecified Error", "Timeout", "Failed", "Invalid Parameter", "DMTF Reserved", "Method Parameters Checked - Job Started", "Invalid logical unit ID", "Invalid initiator port ID", "Invalid target port ID", "Invalid permission", "Target/initiator combination already exposed", "Requested logical unit number in use", "Maximum Map Count Exceeded", "Method Reserved", "Vendor Specific" }] uint32 ExposePaths ( [IN ( false ), OUT, Description ( "Reference to the job if 'Method Parameters Checked - Job " "Started' is returned (MAY be null if job completed).")] CIM_ConcreteJob REF Job, [Required, IN, Description ( "An array of IDs of logical unit instances. The LU " "instances MUST already exist. The members of this array " "MUST match the Name property of LogicalDevice instances " "that represent SCSI logical units. See the method " "description for conditions where this MAY be null."), ModelCorrespondence { "CIM_LogicalDevice.Name"}] string LUNames[], [IN, Description ( "IDs of initiator ports. If existing StorageHardwareID " "instances exist, they MUST be used. Implicit creation " "of StorageHardwareID if no instance matches is " "NOT supported."), 3PAR_TPD.mof 209