HP 3PAR StoreServ 7400 2-node HP 3PAR StoreServ 7000/7450 Storage Cabling Conf - Page 233
Attach DP-2 Chains to Enclosures Between Rack
View all HP 3PAR StoreServ 7400 2-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 233 highlights
Attach DP-2 Chains to Enclosures Between Rack Six meter (6m) cables must be used for connections between racks. Red routing 1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller. 2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller. Green routing 1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller. 2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller. NOTE: The two adjacent enclosures are not directly connected. 4 Node 18 Drive Enclosures (16S+2L) 233
Attach DP-2 Chains to Enclosures Between Rack
Six meter (6m) cables must be used for connections between racks.
Red routing
1.
Connect
Node 0 (DP-2)
to the
I/O 0 (DP-1)
on the
B
drive enclosure closest to the controller.
2.
Connect all
B
drive enclosures from
(DP-2) to (DP-1) working away from the controller.
Green routing
1.
Connect
Node 1 (DP-2)
to
I/O 1 (DP-1)
on the
B
drive enclosure farthest from the controller.
2.
Connect all
B
drive enclosures from
(DP-2) to (DP-1) working toward the controller.
NOTE:
The two adjacent enclosures are not directly connected.
4 Node 18 Drive Enclosures (16S+2L)
233