HP 4400 HP B-series Fabric OS 6.4.1b Release Notes (5697-0886, March 2011-incl - Page 46
is enabled on an HP StorageWorks 1606 Extension SAN Switch., Fabric OS 6.2.x to Fabric OS 6.3.x.
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
Table 9 Fabric OS 6.4.0 closed defects (continued) Closed defect summary Solution Zoning fails with Transaction Commit failed. Reason code 2 (26) - Aca was rejected: Remote Switch Busy, Retry in a few seconds error when E_Port to neighboring Mi10k is lost during a zone push operation when in interop mode. Fixed in Fabric OS 6.4.0 High CPU load from DCFM performing supportsave causes ports to go Fixed in Fabric OS 6.4.0 offline with laser FLT/ link reset. SMI fails to discover all switches over EX_Port after an hafailover, and Fixed in Fabric OS 6.4.0 reports LOGIN FAILED after the GPL2 query targeted to the translate domain is rejected. When a switch running Fabric OS 5.2.x sends an internal query to directors Fixed in Fabric OS 6.4.0 that were not properly set up to handle switches with more than 256 ports, a segmentation fault causes a CALD panic in the fabric. Link timeout occurs on switch port connected to any Access Gateway during Fixed in Fabric OS 6.4.0 hafailover/reboot of AG switch with rlsdisable=0, causing traffic Workaround prior to upgrade: disruption. Configure the settings to disable RLS: Configure -> System services -> Disable RLS probing. Name server database counts do not match for Fabric OS 6.2.1 and M-EOS Fixed in Fabric OS 6.4.0 (9.9.0) switches in the same fabric, so host cannot see the device. This occurs when an HBA capable of a FDMI Register HBA (RHBA) command and M-EOS switch are in the same fabric. Observed termination of snmpd when SNMP queries are sent to the switch, Fixed in Fabric OS 6.4.0 even after deleting LogicalSwitch. Web Tools nameserver is not reflecting the alias and zones created in DCFM. Fixed in Fabric OS 6.4.0 When supportsave on DC SAN Backbone director is collecting the ASICDB Fixed in Fabric OS 6.4.0 data, it ties up the processor and starves other processes. Among other things, this causes CUP timeout messages on the console. Switch panic triggered by size-64 kernel message buffer being used up in virtual fabric with logical ISL configured. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Configure only DISLs between switches. DC SAN Director 6 port 10Gb FC ISL blade set to faulty 21 while traffic running through other blades in the chassis. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Run Slotpoweroff/slotpoweron the FC10-6 blade. During factory install, configdownload does not download some of the Fixed in Fabric OS 6.4.0 FCoE settings in Fabric OS 6.3.0. This issue pertains to the factory only and will not be encountered in the field. Port reference provided to FICON host by Director History Buffer incorrectly Fixed in Fabric OS 6.4.0 references port address rather than port number. This can cause the host to reference the wrong port. Switch is not accessible through Web Tools after firmware upgrade from Fabric OS 6.2.x to Fabric OS 6.3.x. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Access switch via IP address. The switchshow command shows all PIDs the same after reboot for warm Fixed in Fabric OS 6.4.0 upgrade code path of Fabric OS 6.1 to 6.2 to 6.3. After an HCL firmware upgrade, device connectivity is lost when the zone Fixed in Fabric OS 6.4.0 is enabled on an HP StorageWorks 1606 Extension SAN Switch. Observed kernel panic when attempt to delete "base switch" in 8/40 switch. Fixed in Fabric OS 6.4.0 46