In a 2408 FCoE Switch and a 10/24 FCoE Blade, when CNA sends FIP
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Table 9 Fabric OS 6.4.0 closed defects (continued) Closed defect summary ifName value returned for xGBE port in Web Tools does not match CLI output. Copper 1-GbE SFP can get into an illegal state on Extension SAN Switch where no LED light is shown, but port is online and working. GbE ports on HP StorageWorks Extension SAN Switch or Multiprotocol Extension Blade continually showail No_Sync status if non-B-series SFP was inserted and then replaced with B-series SFP. Solution Fixed in Fabric OS 6.4.0 Fixed in Fabric OS 6.4.0 Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use portdisable and portenable after inserting supported SFP. When a host in a backbone fabric with a pair of Multiprotocol Extension Fixed in Fabric OS 6.4.0 blades, 1606 extension SAN switches, or a combination of the two is Workaround prior to upgrade: rebooted, it is unable to discover targets in the edge fabric due to timing window where a SID zone miss could drop a frame. If initiator does not retry Disable and then enable the target. PLOGI, it fails to discover targets in the edge fabric. NPIV tape devices may not be seen by hosts due to name server not sending Fixed in Fabric OS 6.4.0 subsequent PLOGI ACC following a sequence where NPIV device sends LOGO before link down. After upgrade to Fabric OS 6.x, rsh using user credential gets ifmodeshow Fixed in Fabric OS 6.4.0 eth0: ioctl (ETHTOOL_GSET) failed error in response to Workaround prior to upgrade: ifmodeshow command. Telnet and rsh with root credential work fine. Set suid permissions for ethmode: chmod +s /fabos/libexec/ethmode. HP StorageWorks Encryption SAN Switch or encryption blade drops frames Fixed in Fabric OS 6.4.0 received from the host when the back-end tape becomes unresponsive. When an unsupported SFP is installed in an HP StorageWorks DC SAN Director Multiprotocol Extension Blade, the amber LED flashes to indicate a fault, as it should. However, if an optical cable is plugged into the SFP, the amber LED extinguishes. The actual port status is unchanged. Fixed in Fabric OS 6.4.0 When Lossless DLS is enabled, Web Tools incorrectly shows iodset off, but the CLI shows that it is enabled. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use CLI to view the configured IOD state when IOD is enabled with Lossless DLS. In a rare circumstance with a switch running Fabric Watch, a panic can Fixed in Fabric OS 6.4.0 occur after fwd terminated with exit code:134, exit sig:17, and parent sig:0 when IPC buffer is overrun on a busy system. With an HP StorageWorks 1606 SAN Extension Switch and an Multiprotocol Fixed in Fabric OS 6.4.0 Extension Blade, smart data for GE-type ports (such as SFP temperature and power) are not updated in sfpshow by the automatic polling loop. In a 2408 FCoE Switch and a 10/24 FCoE Blade, when CNA sends FIP Fixed in Fabric OS 6.4.0 ver=0, the switch should not validate the MAC descriptor field for backwards compatibility, but it does, leading to the switch rejecting the login. The host cannot recover if a back-end tape target becomes unresponsive during encryption switch-initiated commands. Fixed in Fabric OS 6.4.0 The supportsave command does not capture information for FIDs with index greater than 3. Fixed in Fabric OS 6.4.0 Fabric Watch sometimes logs messages with values above 100%. Most likely Fixed in Fabric OS 6.4.0 occurs during first Fabric Watch polling cycle after a slotstatsclear command is issued. Incorrect port shows I/O traffic on 2408 FCoE Switches and 10/24 Fixed Fixed in Fabric OS 6.4.0 in FCoE Blades. Fabric OS 6.4.0 fixes 55