HP 50 StorageWorks Modular Smart Array 50 Storage Enclosure Maintenance and Se - Page 28
Fault/UID LED, Online/Activity
View all HP 50 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
28 HP StorageWorks Modular Smart Array 50 Storage Enclosure Maintenance and Service Guide Online/Activity LED (green) Fault/UID LED (amber/blue) Flashing regularly Amber, flashing (1 Hz) regularly (1 Hz) Flashing regularly Off (1 Hz) Flashing irregularly Flashing irregularly Off Off Off Amber, flashing regularly (1 Hz) Off Steadily amber Amber, flashing regularly (1 Hz) Off Interpretation Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete. Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding, or it is part of an array that is undergoing capacity expansion or stripe migration. The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is active, and it is operating normally. A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is offline, a spare, or not configured as part of an array.