HP 8/24 Brocade Access Gateway Administrator's Guide v6.3.0 (53-1001345-01, Ju - Page 64

Category, Description, Domains. You cannot create a Trunk Area in AD255.

Page 64 highlights

3 Trunking in Access Gateway mode TABLE 8 Category Access Gateway trunking considerations for the Edge switch Description Fast Write FICON When you assign a Trunk Area to a trunk group, the trunk group cannot have fast write enabled on those ports; if a port is fast write enabled, the port cannot be assigned a Trunk Area. FICON is not supported on F_port trunk ports. However, FICON can still run on ports that are not F_Port trunked within the same switch. FC8-48 blades FC4-32 blade F_Port Trunking does not support shared area ports on the Brocade FC8-48 blades in a 48000. F_Port Trunking is supported on all ports on the Brocade FC8-48 in the DCX and DCX-4S. If an FC4-32 blade has the Trunk Area enabled on ports 16 - 31 and the blade is swapped with a FC8-48 blade, the Trunk Area ports will be persistently disabled. You can run the porttrunkarea command to assign a Trunk Area on those ports. Trunking You must first enable Trunking on the port before the port can have a Trunk Area assigned to it. PID format F_Port masterless trunking is only supported in CORE PID format. Long Distance Port mirroring configdownload and configupload Long distance is not allowed when AG is enabled on a switch. This means you cannot enable long distance on ports that have a Trunk Area assigned to them. Port mirroring is not supported on Trunk Area ports or on the PID of an F_Port trunk port. If you issue the configdownload command for a port configuration that is not compatible with F_Port trunking, and the port is Trunk Area enabled, then the port will be persistently disabled. Note: Configurations that are not compatible with F_Port trunking are long distance, port mirroring, non-CORE_PID, and Fastwrite. ICL port AD If you issue the configupload command, consider the following: • A configuration file uploaded when AG mode is disabled cannot be downloaded when AG mode is enabled. • A configuration file uploaded when AG mode is enabled cannot be downloaded when AG mode is disabled. • A configuration file uploaded when the PG policy is enabled cannot be downloaded when the APC policy is enabled. • A configuration file uploaded when the APC policy is enabled cannot be downloaded when the PG policy is enabled. F_Port trunks are not allowed on ICL ports. The porttrunkarea command does not allow it. You cannot create a Trunk Area on ports with different Admin Domains. You cannot create a Trunk Area in AD255. 44 Access Gateway Administrator's Guide 53-1001345-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

44
Access Gateway Administrator’s Guide
53-1001345-01
Trunking in Access Gateway mode
3
Fast Write
When you assign a Trunk Area to a trunk group, the trunk group
cannot have fast write enabled on those ports; if a port is fast
write enabled, the port cannot be assigned a Trunk Area.
FICON
FICON is not supported on F_port trunk ports. However, FICON
can still run on ports that are not F_Port trunked within the same
switch.
FC8-48 blades
F_Port Trunking does not support shared area ports on the
Brocade FC8-48 blades in a 48000. F_Port Trunking is supported
on all ports on the Brocade FC8-48 in the DCX and DCX-4S.
FC4-32 blade
If an FC4-32 blade has the Trunk Area enabled on ports 16 - 31
and the blade is swapped with a FC8-48
blade, the Trunk Area
ports will be persistently disabled. You can run the
porttrunkarea
command to assign a Trunk Area on those ports.
Trunking
You must first enable Trunking on the port before the port can
have a Trunk Area assigned to it.
PID format
F_Port masterless trunking is only supported in CORE PID format.
Long Distance
Long distance is not allowed when AG is enabled on a switch. This
means you cannot enable long distance on ports that have a
Trunk Area assigned to them.
Port mirroring
Port mirroring is not supported on Trunk Area ports or on the PID
of an F_Port trunk port.
configdownload and configupload
If you issue the
configdownload
command for a port configuration
that is not compatible with F_Port trunking, and the port is Trunk
Area enabled, then the port will be persistently disabled.
Note:
Configurations that are not compatible with F_Port trunking
are long distance, port mirroring, non-CORE_PID, and Fastwrite.
If you issue the
configupload
command, consider the following:
A configuration file uploaded when AG mode is disabled
cannot be downloaded when AG mode is enabled.
A configuration file uploaded when AG mode is enabled
cannot be downloaded when AG mode is disabled.
A configuration file uploaded when the PG policy is
enabled cannot be downloaded when the APC policy is
enabled.
A configuration file uploaded when the APC policy is
enabled cannot be downloaded when the PG policy is
enabled.
ICL port
F_Port trunks are not allowed on ICL ports. The
porttrunkarea
command does not allow it.
AD
You cannot create a Trunk Area on ports with different Admin
Domains. You cannot create a Trunk Area in AD255.
TABLE 8
Access Gateway trunking considerations for the Edge switch
Category
Description