HP 8/24 Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 308
FW-1427, Recommended, Action, Severity, Message, Probable Cause, switchStatusPolicySet
View all HP 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 308 highlights
30 FW-1427 Recommended Replace the faulty or missing power supply. Action Severity WARNING FW-1427 Message , [FW-1427], ,, WARNING, , Switch status change contributing factor Power supply: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the faulty power supply. Action Severity WARNING FW-1428 Message , [FW-1428], ,, WARNING, , Switch status change contributing factor Power supply: absent. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Replace the missing power supply. Action Severity WARNING FW-1429 Message , [FW-1429], ,, WARNING, , Switch status change contributing factor: Power supplies are not redundant. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the power supplies are not in the correct slots for redundancy. Recommended Rearrange the power supplies so that one is in an odd slot and other in an even slot to make them Action redundant. Severity WARNING 256 Fabric OS Message Reference 53-1000600-02