HP 8/24 Brocade Fabric OS Command Reference v6.3.0 (53-1001337-01, July 2009) - Page 789
psShow
View all HP 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 789 highlights
psShow 2 psShow Displays power supply status. Synopsis psshow Description Use this command to display the current status of the switch power supplies. The status of each supply is displayed as: OK Power supply functioning correctly. absent Power supply not present. unknown Unknown power supply unit installed. predicting failure Power supply is present but predicting failure. faulty Power supply present but faulty (no power cable, power switch turned off, fuse blown, or other internal error). For certain switch models, the OEM serial ID data displays after each power supply status line. Note The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details. Operands none Examples To view the status of the power supplies: switch:admin> psshow Power Supply #1 is OK DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #2 is faulty DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #3 is OK DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #4 is absent IXD0111000088 IXD0111000162 IXD0111000120 See Also chassisShow, fanShow Fabric OS Command Reference 759 53-1001337-01