HP 8/40 Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 177
FCPH System Messages
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 177 highlights
Chapter FCPH System Messages 21 FCPH-1001 Message , [FCPH-1001], , FFDC, CRITICAL, , : failed, out of memory condition Probable Cause Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel driver instance. The function can only be " fc_create". This function creates a Fibre Channel driver instance. The failed function call is "kmalloc_wrapper failed". This function call is for kernel memory allocation. Recommended A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will Action automatically fail over, and the standby CP will become the active CP. Severity CRITICAL Fabric OS Message Reference 125 53-1000600-02
Fabric OS Message Reference
125
53-1000600-02
Chapter
21
FCPH System Messages
FCPH-1001
Message
<timestamp>, [FCPH-1001], <sequence-number>, FFDC, CRITICAL, <system-name>,
<function>: <failed function call> failed, out of memory condition
Probable Cause
Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel
driver instance.
The
function
can only be " fc_create". This function creates a Fibre Channel driver instance.
The
failed function call
is "kmalloc_wrapper failed". This function call is for kernel memory
allocation.
Recommended
Action
A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will
automatically fail over, and the standby CP will become the active CP.
Severity
CRITICAL