HP 8/80 Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008 - Page 133
EM-1013, systemVerification, Severity, Message, Probable Cause, Recommended, Action, fruInfoSet
View all HP 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 133 highlights
12 EM-1013 Run the systemVerification command to verify that the switch does not have hardware problems. Refer to the Fabric OS Command Reference for more information on this command. If the message persists, replace the FRU. Severity CRITICAL EM-1013 Message , [EM-1013], ,, ERROR, , Failed to update FRU information for . Probable Cause Indicates that the environmental monitor was unable to update the time alive or the original equipment manufacturer (OEM) data in the memory on a field-replaceable unit (FRU). Recommended Action If you ran the fruInfoSet command, try the command again; otherwise, the update is automatically attempted again. If it continues to fail, try reseating the FRU. If the message persists, replace the FRU. Severity ERROR EM-1014 Message , [EM-1014], ,, ERROR, , Unable to read sensor on () Probable Cause Indicates that the environmental monitor was unable to access the sensors on the specified field-replaceable unit (FRU). Recommended Try reseating the FRU. If the message persists, replace the FRU. Action Severity ERROR EM-1015 Message , [EM-1015], ,, WARNING, , Warm recovery failed (). Probable Cause Indicates that a problem was discovered when performing consistency checks during a warm boot. Recommended Monitor the switch. If the problem persists, a reBoot or power cycle is required to resolve the Action problem. Severity WARNING Fabric OS Message Reference 81 53-1000600-02