connUnitSensorStatus 1.3.6.1.3.94.1.8.1.4
View all HP 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 244 highlights
8 connUnitSensorUnitId 1.3.6.1.3.94.1.8.1.1 connUnitSensorUnitId 1.3.6.1.3.94.1.8.1.1 The connUnitId value of the connectivity unit that contains this sensor table. Set to connUnitId. connUnitSensorIndex 1.3.6.1.3.94.1.8.1.2 A unique value among all connUnitSensorEntrys with the same value of connUnitSensorUnitId, in the range between 1 and the return value from connUnitNumSensor. connUnitSensorName 1.3.6.1.3.94.1.8.1.3 A textual identification of the sensor, intended primarily for operator use. Each contains the name of sensor in textual format: for example, Temp #1, Fan #2, and so on. connUnitSensorStatus 1.3.6.1.3.94.1.8.1.4 The status indicated by the sensor. Values Possible values are: • unknown (1) • other (2) • ok (3) The sensor indicates okay. • Warning (4) The sensor indicates a warning. • failed (5) The sensor indicates failure. • Nominal = 3 (ok). connUnitSensorInfo 1.3.6.1.3.94.1.8.1.5 Return Miscellaneous static information about the sensor, such as its serial number. Each contains textual information about the sensor. Returns the serial ID if this is for the power supply; otherwise, returns Null. connUnitSensorMessage 1.3.6.1.3.94.1.8.1.6 This describes the status of the sensor as a message. It may also provide some information about the sensor, for example: sensor 1: type 3 is OK, value is 33 Each contains the sensor status (and reading if applicable) in textual format. 226 Fabric OS MIB Reference 53-1001339-01