HP 8/80 Brocade Fabric OS MIB Reference v6.3.0 (53-1001339-01, July 2009) - Page 91
fcFxPortRatov 1.3.6.1.2.1.75.1.1.5.1.7
View all HP 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
fcFxPortBbCredit 1.3.6.1.2.1.75.1.1.5.1.5 3 fcFxPortBbCredit 1.3.6.1.2.1.75.1.1.5.1.5 The total number of receive buffers available for holding Class 1 connect-request, and Class 2 or 3 frames from the attached Nx_Port. It is for buffer-to-buffer flow control in the direction from the attached Nx_Port (if applicable) to Fx_Port. fcFxPortRxBufSize 1.3.6.1.2.1.75.1.1.5.1.6 The largest Data_Field Size (in octets) for an FT_1 frame that can be received by the Fx_Port. fcFxPortRatov 1.3.6.1.2.1.75.1.1.5.1.7 The Resource_Allocation_Timeout value configured for the Fx_Port. This is used as the time-out value for determining when to reuse an Nx_Port resource such as a Recovery_Qualifier. It represents E_D_TOV (Refer to "fcFxPortEdtov 1.3.6.1.2.1.75.1.1.5.1.8" on page 73) plus twice the maximum time that a frame might be delayed within the fabric and still be delivered. fcFxPortEdtov 1.3.6.1.2.1.75.1.1.5.1.8 The E_D_TOV value configured for the Fx_Port. The Error_Detect_Timeout value is used as the time-out value for detecting an error condition. fcFxPortCosSupported 1.3.6.1.2.1.75.1.1.5.1.9 A value indicating the set of Classes of Service supported by the Fx_Port. fcFxPortIntermixSupported 1.3.6.1.2.1.75.1.1.5.1.10 A flag indicating whether the Fx_Port supports an Intermixed Dedicated Connection. 1 - true 2- false fcFxPortStackedConnMode 1.3.6.1.2.1.75.1.1.5.1.11 A value indicating the mode of Stacked Connect supported by the Fx_Port. 1 - none 2 - transparent 3 - locked down Fabric OS MIB Reference 73 53-1001339-01