HP Cisco MDS 9124 HP StorageWorks C-Series iSCSI Configuration Guide (AA-RW7PE - Page 36

Zoning the iSCSI Initiator and Fibre Channel storage WWPNs, Creating zones

Page 36 highlights

Figure 29 Discovery Dynamic check box 3. Select the Node Address Persistent check box (Figure 30). 4. Select the Node Address System Assigned check box (Figure 30). Figure 30 Node Address Persistent and Node Address System Assigned check boxes 5. Click Apply. 6. Close the IP iSCSI window. 7. Select Admin > Save Configuration from the Device Manager menu bar. 8. Configure transparent-mode static mapping on both iSCSI-enabled C-Series switches. Zoning the iSCSI Initiator and Fibre Channel storage WWPNs The unique WWPN of the iSCSI Initiator acts as a virtual Fibre Channel host available on the Fibre Channel SAN. The WWPN is zoned with Fibre Channel storage as if it were a Fibre Channel HBA. Creating zones Use either the Fabric Manager or the switch CLI to create and modify SAN zones. HP recommends creating separate iSCSI zones that contain the iSCSI WWPNs and the storage WWPNs that they access. See the Cisco configuration documentation for information on creating, modifying, or activating SAN zones. Figure 31 shows an iSCSI Initiator zoned with an Enterprise Virtual Array storage port. 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49

Figure 29 Discovery Dynamic check box
3.
Select the
Node Address Persistent
check box (
Figure 30
).
4.
Select the
Node Address System Assigned
check box (
Figure 30
).
Figure 30 Node Address Persistent and Node Address System Assigned check
boxes
5.
Click
Apply
.
6.
Close the IP iSCSI window.
7.
Select
Admin > Save Con
guration
from the Device Manager menu bar.
8.
Con
gure transparent-mode static mapping on both iSCSI-enabled C-Series switches.
Zoning the iSCSI Initiator and Fibre Channel storage WWPNs
The unique WWPN of the iSCSI Initiator acts as a virtual Fibre Channel host available on the Fibre
Channel SAN. The WWPN is zoned with Fibre Channel storage as if it were a Fibre Channel HBA.
Creating zones
Use either the Fabric Manager or the switch CLI to create and modify SAN zones. HP recommends
creating separate iSCSI zones that contain the iSCSI WWPNs and the storage WWPNs that they access.
See the Cisco con
guration documentation for information on creating, modifying, or activating SAN
zones.
Figure 31
shows an iSCSI Initiator zoned with an Enterprise Virtual Array storage port.
36