HP Cisco Nexus 5000 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS R - Page 34

When a Cisco Fabric Switch for HP c-Class BladeSystem or Cisco Fabric Switch for, Symptom, Workaround

Page 34 highlights

Caveats Send documentation comments to [email protected] Symptom: When NPV is enabled, IP access list commands are not accessible. Workaround: This issue is resolved. • CSCsz40628 Symptom: An Inter-Switch Link (ISL) does not come up after one switch reloads. Workaround: This issue is resolved. • CSCsz70307 Symptom: While Fabric Manager discovers the fabric, SNMP fails and the switch reloads. The HBAs of the end devices in the fabric have Fabric-Device Management Interface (FDMI) enabled. Workaround: This issue is resolved. • CSCsz74907 Symptom: In very rare circumstances, the zone server might fail due to a heartbeat failure. Workaround: This issue is resolved. • CSCsz75692 Symptom: When a Cisco Fabric Switch for HP c-Class BladeSystem or Cisco Fabric Switch for IBM BladeCenter reloads following the system startup-config init command, the switch does not auto boot, but remains at the loader prompt. The command erroneously erases the startup configuration from the boot flash. Workaround: This issue is resolved. • CSCsz84022 Symptom: The TPC application cannot discover the MDS 9509 switch when it is connected to an MDS 9020 switch. Workaround: This issue is resolved. • CSCsz95999 Symptom: A kernel failure in the Mgmt0 driver caused the MDS 9222i switch to reboot Workaround: This issue is resolved. • CSCta08796 Symptom: A memory leak caused the port manager to fail and put the ports in a hardware failure state. Workaround: This issue is resolved. • CSCta15575 Symptom: The SystemName property on the CIM Server is returning the wrong values for N port and F port. Workaround: This issue is resolved. • CSCta28642 Symptom: SNMP should gracefully handle timeouts caused by port initialization. Workaround: This issue is resolved. • CSCta34629 Symptom: The system manager core server does not clean up the core files on the MDS 9513 switch. Workaround: This issue is resolved. Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(4) 34 OL-14116-12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Send documentation comments to [email protected]
34
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(4)
OL-14116-12
Caveats
Symptom
: When NPV is enabled, IP access list commands are not accessible.
Workaround
: This issue is resolved.
CSCsz40628
Symptom
: An Inter-Switch Link (ISL) does not come up after one switch reloads.
Workaround
: This issue is resolved.
CSCsz70307
Symptom
: While Fabric Manager discovers the fabric, SNMP fails and the switch reloads. The
HBAs of the end devices in the fabric have Fabric-Device Management Interface (FDMI) enabled.
Workaround
: This issue is resolved.
CSCsz74907
Symptom
: In very rare circumstances, the zone server might fail due to a heartbeat failure.
Workaround
: This issue is resolved.
CSCsz75692
Symptom
: When a Cisco Fabric Switch for HP c-Class BladeSystem or Cisco Fabric Switch for
IBM BladeCenter reloads following the
system startup-config init
command, the switch does not
auto boot, but remains at the loader prompt. The command erroneously erases the startup
configuration from the boot flash.
Workaround
: This issue is resolved.
CSCsz84022
Symptom
: The TPC application cannot discover the MDS 9509 switch when it is connected to an
MDS 9020 switch.
Workaround
: This issue is resolved.
CSCsz95999
Symptom
: A kernel failure in the Mgmt0 driver caused the MDS 9222i switch to reboot
Workaround
: This issue is resolved.
CSCta08796
Symptom
: A memory leak caused the port manager to fail and put the ports in a hardware failure
state.
Workaround
: This issue is resolved.
CSCta15575
Symptom
: The SystemName property on the CIM Server is returning the wrong values for N port
and F port.
Workaround
: This issue is resolved.
CSCta28642
Symptom
: SNMP should gracefully handle timeouts caused by port initialization.
Workaround
: This issue is resolved.
CSCta34629
Symptom
: The system manager core server does not clean up the core files on the MDS 9513
switch.
Workaround
: This issue is resolved.