HP Cisco Nexus 5000 HP StorageWorks C-Series Fabric Switches for SAN-OS 3.3(1c - Page 18

HP Specific Known Issues - blade

Page 18 highlights

HP Specific Known Issues Problem Description: If an EVA controller running VCS 3.xxx is restarted, paths may fail to return on the C-Series MDS 9020. Workaround: Disable and then re-enable the port the EVA is plugged into. Problem Description: EVA controllers running XCS 5.1xx or later may fail to log into the CSeries switches. Workaround: Set the switch port mode to F or FX and specify the speed (2Gbps or 4Gbps). Should the EVA controller fail to log in, unplug and reinsert the fibre channel cable. Problem Description: If it becomes necessary to move an EVA controller port to a different port on the same C-Series switch, or to a port on a different C-Series switch, the corresponding controller port may become unavailable. Workaround: Restart the EVA controller. Problem Description: EVA controllers running VCS 3.xxx may log into the C-Series 4Gbps modules at 1Gbps instead of the default 2Gbps. Workaround: Set the switch port speed to 2Gbps. Problem Description: Continuous Access EVA VCS 3.xxx, VCS 4.xxx, and XCS 5.xxx is nonoperational with the C-Series MDS 9020. Workaround: None for VCS 3.xxx or VCS 4.xxx. For XCS 5.xxx, upgrade to XCS 6.xxx. Refer to the EVA XCS 6.xxx documentation for upgrade restrictions. Problem Description: The HP ProLiant family of blade servers may display as storage arrays in the Fabric Manager topology diagram. Workaround: Perform the following steps to change the display of the blade server from a storage icon to a host icon. This issue will be resolved in a future version of Fabric Manager. 1. Log into Fabric Manager 2. Under "Physical Attributes" open "End Devices" 3. Select "Storage" and click on the "Enclosures" tab in the Information Pane 4. Under "Device Type" for the desired device, select "HBA" 5. Save changes by selecting the "Apply Changes" icon on the top left corner of the Information Pane Problem Description: VMware ESX on HP c-Class BladeSystem Server Blade using QMH2462 HBAs and FC Pass-Thru Module may fail to log into the C-Series MDS 9216, MDS 9216A, or 16-port switching module. Workaround: Set the switch port mode to F. Problem Description: VMware ESX on HP c-Class BladeSystem Server Blade using QMH2462 HBAs and FC Pass-Thru Module logs into the MDS 9020 as an FL port if the switch port mode is set to auto. Workaround: Set the switch port mode to F. 18 MDS Multilayer Director & Multilayer Fabric Switches Release Notes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

18
MDS Multilayer Director & Multilayer Fabric Switches Release Notes
HP Specific Known Issues
Problem Description:
If an EVA controller running VCS 3.xxx is restarted, paths may fail to
return on the C-Series MDS 9020.
Workaround:
Disable and then re-enable the port the EVA is plugged into.
Problem Description:
EVA controllers running XCS 5.1xx or later may fail to log into the C-
Series switches.
Workaround:
Set the switch port mode to F or FX and specify the speed (2Gbps or 4Gbps).
Should the EVA controller fail to log in, unplug and reinsert the fibre channel cable.
Problem Description:
If it becomes necessary to move an EVA controller port to a different
port on the same C-Series switch, or to a port on a different C-Series switch, the corresponding
controller port may become unavailable.
Workaround:
Restart the EVA controller.
Problem Description:
EVA controllers running VCS 3.xxx may log into the C-Series 4Gbps
modules at 1Gbps instead of the default 2Gbps.
Workaround:
Set the switch port speed to 2Gbps.
Problem Description:
Continuous Access EVA VCS 3.xxx, VCS 4.xxx, and XCS 5.xxx is non-
operational with the C-Series MDS 9020.
Workaround:
None for VCS 3.xxx or VCS 4.xxx.
For XCS 5.xxx, upgrade to XCS 6.xxx.
Refer to the EVA XCS 6.xxx documentation for upgrade restrictions.
Problem Description:
The HP ProLiant family of blade servers may display as storage arrays
in the Fabric Manager topology diagram.
Workaround:
Perform the following steps to change the display of the blade server from a
storage icon to a host icon.
This issue will be resolved in a future version of Fabric Manager.
1.
Log into Fabric Manager
2.
Under “Physical Attributes” open “End Devices”
3.
Select “Storage” and click on the “Enclosures” tab in the Information Pane
4.
Under “Device Type” for the desired device, select “HBA”
5.
Save changes by selecting the “Apply Changes” icon on the top left corner of the
Information Pane
Problem Description:
VMware ESX on HP c-Class BladeSystem Server Blade using
QMH2462 HBAs and FC Pass-Thru Module may fail to log into the C-Series MDS 9216, MDS
9216A, or 16-port switching module.
Workaround:
Set the switch port mode to F.
Problem Description:
VMware ESX on HP c-Class BladeSystem Server Blade using
QMH2462 HBAs and FC Pass-Thru Module logs into the MDS 9020 as an FL port if the switch
port mode is set to auto.
Workaround:
Set the switch port mode to F.