- HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 1
HP Integrity Superdome 2 Onboard Administrator User Guide Abstract This document contains specific information that is intended for users of this HP product. HP Part Number: AH337-9001G Published: November 2013 Edition: 9 - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP commercial license. Microsoft®, Windows®, and Windows Server® are U.S. registered trademarks of Microsoft - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 3
GUI 15 Running the setup wizard...15 Using online help...16 Changing enclosure and device configurations 16 Recovering the administrator password 17 2 HP Integrity Superdome 2 Insight Display 18 HP Integrity Superdome 2 Insight Display components 18 Insight Display overview...18 Running the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 4
screen 67 Online complex firmware update on Superdome 2 68 Introduction...68 Services unavailable...69 Management Processor access 69 IPMI...70 Update screen...74 Enclosure DVD Module screen 77 7 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices...79 Viewing the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 5
AlertMail screen...83 Device Power Sequence Device Bays tabs 85 Device Power Sequence Interconnect Bays tab 87 Date and Time screen...87 Enclosure TCP/IP Settings screen 88 Network Access screen...89 Trusted Hosts tab...90 Anonymous Data tab...91 Link Loss Failover screen...91 Enclosure Bay IP - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 6
156 8 HP Integrity Superdome 2 IOX Superdome 2 compute enclosures 163 10 Using the CLI 164 Command line overview...164 11 Using the serial connection 165 Setting up Onboard Administrator using the CLI 165 Pinout signals for Onboard Administrator Serial RS232 connector 165 Using the service - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 7
the directory login solution 185 Troubleshooting LDAP on Onboard Administrator 185 15 Support and other resources 187 Before you contact HP...187 HP contact information...187 Subscription service...187 Documentation feedback...187 Installing HP Insight Remote Support Software 187 New and changed - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 8
and configuration of the complex components, and informs you of problems within the complex through email, SNMP, or the Insight Display. HP recommends that you read the HP Integrity Superdome 2 User Service Guide for complex specific information before proceeding with the Onboard Administrator - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 9
is available from VCM or iLO 3 on any server. Insight Display. Yes. Complete control. No. an Onboard Administrator module in a Superdome 2 enclosure with a redundant Onboard Administrators have the same network settings and no manual update is required. • If the complex firmware versions - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 10
HP Integrity Superdome 2 Onboard Administrator Command Line Interface User Guide. Access requirements To access the HP Superdome browsers can be used but are not supported. Before running the application, you must get/set SNMP traps LDAP Terminal services pass-through from PC to OA Incoming - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 11
removal Onboard Administrator provides component control in HP Integrity Superdome 2 Blade Enclosures. Component management begins • Onboard Administrator provides easy-to-understand port mapping information for each server blade and interconnect module in each enclosure. The NIC and mezzanine option - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 12
server blades. A complex can contain one or more nPartitions, enabling the hardware to function as a single system or as multiple systems. NOTE: For more information about partition creation and management, see the HP Integrity Superdome 2 Partitioning Administrator Guide. Interfaces Each Superdome - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 13
a Superdome 2 compute enclosure and diagnostic information if the Onboard Administrator detects a problem in For complexes that have the HP Superdome 2 Door Status Display, the enclosure service port is routed through of multiple administrative roles such as server, LAN, and SAN. User accounts - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 14
the web GUI to graphically view and manage the HP Superdome 2 components in the entire complex. For example DHCP server, then the Onboard Administrator modules and interconnect modules supporting service port, or by using the Enclosure KVM - Onboard Administrator CLI button. An alternative to manual - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 15
case-sensitive. • The account information entered not being set up for HP Superdome 2 Onboard Administrator. • The user name entered has been deleted, the administrator password" (page 17). If you continue to have problems signing in, contact your administrator. Running the setup wizard To run - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 16
configuration changes at any time. See "Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices" (page 79) for information that helps you make changes to enclosure and device configuration, user setup, and LDAP server settings and LDAP groups. See "Enclosure power management - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 17
Recovering the administrator password If the administrator password has been lost, you can reset the administrator password to the factory default that shipped on the tag with the Onboard Administrator module. The Onboard Administrator resets a lost password to Lost Password mode. To recover the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 18
2 HP Integrity Superdome 2 Insight Display HP Integrity Superdome 2 Insight Display components Item Description Function 1 Insight Display screen Displays Main Menu error messages and instructions 2 Left arrow button Moves the menu or navigation bar selection left one position 3 Right - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 19
configuring the enclosure, the Insight Display verifies that no installation or configuration errors are present. If errors are present, the Insight Display guides you through the process of correcting the errors. To identify the enclosure, the rear enclosure UID light and the background of the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 20
the maximum to prevent tripping the circuit breaker (United States only). NOTE: If your facility cannot support the calculated peak Watts ac, set the Power Watts ac value to match the capability of your is installed, the screen displays "Not Present." 20 HP Integrity Superdome 2 Insight Display - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 21
character. The box character is used to signal the end of the name. • DVD Drive- The DVD connection Settings screen is a table of all the servers with the status of DVD Connection and blade name for that blade. ◦ Detach/Attach-Each blade can be individually attached to or detached from the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 22
screen appears. See "Insight Display errors" (page 30) for more information on troubleshooting configuration and installation errors. NOTE: Any configuration error prevents the operation of the the Onboard Administrator First Time Installation Wizard. 22 HP Integrity Superdome 2 Insight Display - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 23
10. Navigate to Help, and then press OK to view the Help: DVD Connection screen. • An exclamation icon indicates no DVD drive and disk is detected or firmware upgrade is needed for this feature. • A bright green DVD icon indicates the Enclosure DVD media is connected to the blade. • A gray DVD icon - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 24
screen When an error or alert condition is detected, the Health Summary screen displays the total number of error conditions and the error locations. 24 HP Integrity Superdome 2 Insight Display - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 25
can be removed from the drive. A bright green rectangle indicates that the media is present in the drive and actively connected to at least one server in the enclosure, and the drive tray is locked. If an error occurs, the Health Summary screen background changes from green to amber and the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 26
information about the enclosure, including: • Active OA IP address • Active OA Service IP address • Current health status of the enclosure • Current enclosure ambient temperature • Current ac input power to the enclosure • Enclosure name • Rack name 26 HP Integrity Superdome 2 Insight Display - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 27
and Port Info screen displays information about a specific server blade. On the first screen, select the server blade number, and then press the OK button. Select Blade Info or Port Info, and then press the OK button. To view information about the server blade, select Blade Info, and then press the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 28
blade, select Port Info, and then press the OK button. The following screen shows a server blade with four embedded NICs. The other interconnect bays are empty. The four embedded NICs UID LED and changes the color of the Insight Display screen to blue. 28 HP Integrity Superdome 2 Insight Display - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 29
to the current alert condition. View User Note screen The View User Note screen displays six lines of text, each containing a maximum of 16 characters. Use this screen to display helpful information such as contact phone numbers. Change this screen using the remote Onboard Administrator user web - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 30
because of insufficient power to bring up an enclosure. Power errors can occur on server blades, storage blades, or interconnect modules. To correct a power error: 1. on server blades, storage blades, or interconnect modules. To correct a cooling error: 30 HP Integrity Superdome 2 Insight Display - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 31
the mezzanine card installation. (The Insight Display indicates the correct bay.) For information on installing the mezzanine card, see the server-specific user guide on the Documentation CD. Device failure errors Device failure errors occur when a component has failed. Device failure errors can - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 32
2 SD2-16s and SD2-32s complexes that are factory integrated ship with the HP Superdome 2 Door Status Display. The Door Display is a quick method of getting basic complex status information by using the integrated touch screen on the rack door. NOTE: HP Superdome 2 SD2-8s complexes do not support the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 33
The startup menu has the following options: • Disable Display-A screen saver immediately appears for one hour, and then the Door Display shuts off. • Setup-Select this option to begin the Door Display setup. Complex configuration Select the current complex configuration in the rack. Setting up the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 34
of the IP addresses of the active Onboard Administrator and the complex service port. NOTE: The OA IP address does not appear until the setup process is complete. Press Next to continue. Two 16s complex setup If the complex configuration is 2 16s complexes in a Cabinet, unlike the other multi- - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 35
the rack. • Upper Complex-The Door Display screen displays status information for only the upper SD2-16s complex in the rack. • Both Complexes-The Door Display screen displays status information for both SD2-16s complexes in the rack. NOTE: If you select Both Complexes, you are prompted to enter two - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 36
cannot be used to set the enclosure UID. Press Login to complete setup or Cancel to quit Door Display setup. Door Display status menu 36 HP Superdome 2 Door Status Display - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 37
IP address of the active Onboard Administrator. • Service IP address-The IP address of the complex service port. • Enclosure power-The current power -Display the UID control overlay. If the rack contains two SD2-16s complexes, then the Door Display status menu displays the following buttons: - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 38
can use the Door Display. • Calibrate Screen- Enters calibration mode for the touch screen. IMPORTANT: HP recommends using a stylus or the back of a pencil to calibrate the screen. Using a finger is firmware can be reloaded using the Firmware Update menu. 38 HP Superdome 2 Door Status Display - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 39
for the Door Display. ◦ No Update Available- The OA does not have firmware available for the Door Display. This occurs if the OA web server is disabled. NOTE: The Door Display firmware must be updated through the Door Display menu. • Reboot Display- Restarts the Door Display module only. IMPORTANT - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 40
you do not want to reboot the Door Display, press Not Now. The firmware update is not complete until the Door Display is rebooted. 40 HP Superdome 2 Door Status Display - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 41
not enable you to set up and configure partitions. For information on partition creation and management, see the HP Integrity Superdome 2 Partitioning Administrator Guide. Before you begin Before running the First Time Setup Wizard, complete the following tasks: 1. Install the Onboard Administrator - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 42
If more than one enclosure is listed on the Enclosure Selection screen, select the enclosure you want to set up, and then click the Next button. For possible values and descriptions of each box, see "Enclosure Settings screen" (page 80). Configuration Management screen The Configuration Management - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 43
is 256. Click Upload after entering the script file path. • URL: Enter an http:// path to the configuration file if it is located on a web server. The maximum number of characters in the file path is 256. Click Upload after entering the URL. A window opens and displays the results. If more - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 44
primary NTP server that provides date and time information Secondary NTP Server where ### ranges from 0 to 255 IP address of secondary NTP server that provides asset tag is blank. See the HP Integrity Superdome 2 User Service Guide for more information on connecting enclosures. Administrator - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 45
Box Password Password Confirm Full Name Contact PIN Code PIN Code Confirm Possible value Description 3 to 8 characters including all printable characters The password for the Administrator account 3 to 8 characters including all printable characters Must match the Password value 0 to 20 - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 46
save the information. 3. To return to the Local User Accounts screen, click Cancel. 4. For each user added, select the appropriate boxes to grant access to servers and interconnect bays. For possible values and descriptions of each box, see "Managing users" (page 140). 46 First Time Setup Wizard - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 47
processors, Onboard Administrator CLI hponcfg command can be used with HP ProLiant server blades to send the iLO network settings RIBCL script to an network has an external DHCP service or if you want to manually assign static IP addresses one by one to the server blades and interconnect modules, - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 48
for accessing information directories. While LDAP is based on the X.500 standard, it is significantly simpler. LDAP supports TCP/IP, which enables applications to work independently of the server hosting the directory. Use the Directory Group screen to set directory access for the now selected - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 49
or the DNS name or the from 0 to 255 or DNS name of the name of the domain of the directory service directory server or the name of the domain Directory Server SSL Port 0 to xxxx The port used for LDAP communications. The default port is port 636 Search Context 1 All characters except - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 50
for DHCP and static IP are supported. • Use DHCP for all Active Onboard Administrators: Get the IP address for the Onboard Administrator from a DHCP server. The Standby check box is shown or modify the SNMP settings for the active HP Superdome 2 Onboard Administrator. 50 First Time Setup Wizard - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 51
in the Power Redundancy Status becoming Failed. The administrator must explicitly reduce the redundancy setting to enable powering on servers prior to the failed power supplies being serviced. This applies to AC Redundant and Power Supply Redundant power modes. NOTE: If redundancy mode is set to - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 52
The Superdome 2 enclosure power management system enables you to customize the configuration of the enclosure. You can select from the various modes on the Onboard Administrator Power - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 53
efficiency. • Disabled: All power supplies share the load. The power subsystem efficiency varies based on load. Dynamic Power is not supported for low voltage on the Superdome 2 enclosure. Finish You can clear the Do not automatically start this wizard again check box to force the First Time Setup - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 54
Click the Finish button to save and exit the First Time Setup Wizard. The First Time Setup Wizard screen closes and you are returned to the default main screen of the Superdome 2 Onboard Administrator. 54 First Time Setup Wizard - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 55
5 Navigating Onboard Administrator Navigation overview The main HP Superdome 2 Onboard Administrator navigation system consists two views: • Tree view: Lists all of the complex devices on the left side of the main page and remains - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 56
One of the main purposes of the tree view is to enable navigation using categories based on the major systems within the complex. When a category is expanded (by clicking the white plus icon on the blue box to the left of the category), an icon next to the category name can indicate a degraded - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 57
in the graphical view. Links to system forms do not display status icons. Graphical view navigation The second component of the HP Superdome 2 Onboard Administrator GUI navigation system is a graphical representation of physical enclosures, called the graphical view. The graphical view consists of - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 58
Selecting a device To select a device, click the graphical representation of the device in the front or rear graphical view. When you select a device, its border changes from gray to light blue indicating that it is the now selected device. Selecting a device in the graphical view selects the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 59
and a padlock icon appears in the bay table cell, indicating that the bay is locked to the current user. The user cannot select a locked bay. When the user hovers the mouse over the locked bay, a message appears, indicating that the user does not have permission to access devices in that bay. - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 60
6 Complex Overview Complex Overview screen The Complex Overview screen displays a graphical representation of each compute enclosure in the complex, called the graphical view. The graphical view consists of a front view and a rear view of each enclosure. The front view shows the presence and status - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 61
Compute Enclosures tab Item Enclosure Name Enclosure ID Serial Number Part Number Asset Tag UID State Insight Display Description The DNS name of the enclosure and the name of the enclosure in the rack. The ID for the Enclosure in a multi-enclosure system. The unique serial number of the enclosure - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 62
Table 2 Compute enclosure cooling requirements Item Current Btu/hr Max Btu/hr Description The sum of the amount of heat being generated by the complex enclosures measured in Btu per hour. The maximum amount of heat that can be generated by the complex enclosures under load measured in Btu per hour - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 63
in the Power Redundancy Status becoming Failed. The administrator must explicitly reduce the redundancy setting to enable powering on servers prior to the failed power supplies being serviced. This applies to AC Redundant and Power Supply Redundant power modes. NOTE: If redundancy mode is set to AC - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 64
Item Complex Status CAMNET Status Robust Store Status Cooling Status Thermal Status Product ID Enclosure ID Description The overall health of the complex. Possible values are Unknown, OK, Degraded, and Failed. The overall health of the CAMNET fabric in the complex. Possible values are Unknown, OK, - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 65
Enclosure Status Overview Column Enclosure Number Enclosure Name Status Description The number of the compute enclosure in the complex. The assigned name of the compute enclosure. The overall health of the compute enclosure. Possible values are Unknown, OK, Degraded, and Failed. IOX Status - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 66
the complex Current Product Number The current product number of the complex Serial Number The unique manufacturer serial number of the Superdome 2 complex Universal Unique Identifier The Universally Unique Identifier number assigned to the complex (UUID) Monarch Enclosure Number The number of - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 67
the current status of firmware in the complex. Superdome 2 systems support two types of firmware, complex firmware that must be consistent across all devices in the complex, and partition firmware that runs on the system processors of server - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 68
release bundle 2.2.27 (web released in August 2011, factory enabled in September 2011), brings an exciting capability to Superdome 2 customers. The ability to support online complex firmware updates can dramatically reduce the amount of partition downtime required for a customer to update their - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 69
Services unavailable Superdome 2 server management features are unavailable during the process of an online complex firmware update. System firmware will continue to operate and support Network management services (SD2 has additional Unavailable services). OS-debugger, HP-SIM XML query, HP-SUM SOAP - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 70
firmware update, no IPMI requests can be serviced until the update completes. This means that System Event Logs normally captured by the server management system will not be updated during call which may fail during the firmware update process. HP-UX caches this information after the very first call - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 71
should not inhibit OS problem diagnosis in the shutdown -r) • MCA • HP-UX boot may hang until server management resources. The following services server management that an MCA has occurred once the firmware update completes, and server management will ensure the partition is reset and data integrity - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 72
firmware version, which is sourced via IPMI. Network Services to OA All network services provided by the OA are interrupted by the firmware update process. These services include: • XML inventory query from HP-SIM • WS-MAN partition query from HP-SIM and plugins • User interface (ssh, web, telnet - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 73
update? • Answer: HP can not guarantee . 4. How does field support debug if something happened during it was on legacy sx2000 Superdome systems), but the SEL will ready to talk to server management. From an application viewpoint, the process completes. The service processor is unavailable - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 74
problems. Serviceguard Manager performance degradation and proxy errors Serviceguard Manager may experience some performance degradation or report proxy errors during Superdome Server response. par* and vpar* commands fail Parcon services are not available during Superdome the HP Superdome 2 Onboard - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 75
have complex firmware earlier than the Online Firmware Update firmware release, see the UPDATE FIRMWARE section in the HP Integrity Superdome 2 Onboard Administrator Command Line Interface User Guide. If you select the firmware update link in the left navigation panel, the firmware update selections - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 76
If the analysis fails, you will not be supplied with further options. If the Analysis Only option was not selected, then the firmware update will automatically continue after 30 seconds. During this time the you will have the option to cancel the update using the Cancel Update button at the bottom - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 77
The following information will be displayed: • The status of each component being updated. • The total number of components that will be updated. • The number of component updates either completed successfully or failed. • The estimated time remaining in the update. IMPORTANT: When two partitions - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 78
CLI or by navigating to the Complex nPartitions menu and selecting the Virtual Devices tab. For more information, see the HP Integrity Superdome 2 Partitioning Administrator Guide. Information on the Enclosure DVD screen is current as of the last download. To view updated information, click the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 79
7 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices Viewing the status Normal/OK • Disabled • Unknown • Informational The Active HP Superdome 2 Onboard Administrator Status and Standby HP Superdome 2 Onboard Administrator Status are similar to the Overall Enclosure Status - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 80
procedures to configure the management functionality provided by the HP Superdome 2 Onboard Administrator. Select the tree view menu item . For information on these modes, see the HP Integrity Superdome 2 User Guide. 80 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 81
the error are mismatched firmware or a software or hardware failure. Device Indictment Indicates if the device has been indicted by the Superdome 2 Analysis Engine. Table 7 Subsystems and Devices information Table Device Bay Overview All Device Bays Description The overall status of all device - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 82
The part number to be used when ordering an additional enclosure component The part number to be used when ordering a replacement enclosure component 82 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 83
independent from SNMP, and both can be enabled at the same time. AlertMail uses standard SMTP commands to communicate with an SMTP-capable mail server. The "Reply To" address for each email sent by AlertMail is @. To enable the AlertMail feature, select the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 84
dash Administrator resides (-) where ### ranges An IP address for the SMTP server from 0 to 255 To enable the AlertMail feature: 1. Select the standard format Subject: HP AlertMail-SEQ: SUBJECT To: RECEIVER MAILBOX 84 Configuring HP Integrity Superdome 2 compute enclosures and - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 85
easily identify the order of events in case the mail server distributes them in the wrong order. Sequence numbers range Status: Degraded Enclosure Management URL: https://16.181.75.213/ - PLEASE DO NOT component in the enclosure. The active HP Superdome 2 Onboard Administrator displays a message in - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 86
servers that are configured to boot from SAN • Critical service dependencies controlled by a server such as DHCP or licensing • Storage servers must be operational prior to servers device is installed in the bay 86 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 87
Column Enabled Delay Device Power Sequence Interconnect Bays tab Description Enables power sequencing, disables power sequencing, or does not allow powering on of the device if No Poweron is selected. The amount of delay, in seconds, before the device powers on. Column Bay Device Enabled Delay - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 88
powered on to be sure that the Enclosure IP Mode settings are not changed. • DHCP- Gets the IP address for the Onboard Administrator from a DHCP server 88 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 89
0 to 255 where ### ranges from The IP address for the secondary DNS server 0 to 255 NIC settings • Auto-Negotiate- Automatically configures the best link. This is the default setting. This option supports a NIC speed of 10 Mb/s, 100 Mb/s, or 1000 Mbps. The 1000 Mb/s setting is only available - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 90
enables XML data to be shared between the Onboard Administrator and other HP management tools such as HP Systems Insight Manager. To display the information that is shared by the the settings, click the Apply button. 90 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 91
bridged through the Onboard Administrator and must not be confused with port mapping for the server blade NICs or for network routers or switches. EBPIA does not assign IP addresses for up link-local addresses, see the HP Integrity Superdome 2 Command Line Interface User Guide. Enclosure settings 91 - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 92
bay EBIPA range to 16.200.139.51 to 16.200.139.58. If you set the interconnect module port, the interconnect bay #1 is set to 16.200.139.51 and the interconnect module management port in Interconnect bay #7 is set to 16.200.139.57. 92 Configuring HP Integrity Superdome 2 compute enclosures and - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 93
EBIPA ensures an easy setup and enables you to install your HP Superdome 2 Onboard Administrator on to your network quickly. Record the in the following table. Box Subnet Mask Gateway Domain DNS Server 1 DNS Server 2 DNS Server 3 Possible value Description where ### ranges from 0 Subnet mask - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 94
type of device installed in the device bay. SNMP Settings screen The Onboard Administrator supports SNMP Version 1 and several groups from the standard MIB-II MIB. Additional information can be enabled and configured. 94 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 95
an individual or group of individuals who are the space to be contacted in the event of any status change in the HP Superdome 2 Onboard Administrator. 0 to 20 characters including all alphanumeric The Read Community string enables the client characters, the dash (-), the underscore (_), and to - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 96
security reasons, the retrieved current configuration does not contain any user passwords. You can manually edit the script to add the user passwords after the user name on the ADD added from the configuration script. 96 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 97
on all FRUs within the enclosure. Information provided in this section can quickly aid the administrator in contacting HP Customer Service for troubleshooting, repairing, and ordering replacements. The information is organized in tabular format and divided into subcategories within the Device - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 98
installed in the enclosure, you can manually change the active Onboard Administrator. This feature can be useful when troubleshooting the Onboard Administrator or if a second about your Onboard Administrator. 98 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 99
Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a failure has occurred) or is sent by the device microcontroller, without being polled, to report a failure. Active Onboard Administrator Status and Information tab Table 8 Status information - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 100
Onboard Administrator module UID LED. This button is useful in identifying a particular Onboard Administrator when there is more than one in the enclosure. 100 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 101
TCP/IP Settings screen This screen displays the current enclosure TCP/IP settings for the active Onboard Administrator. To change these settings, select Click here. For information on modifying the TCP/IP settings, see "Enclosure TCP/IP Settings screen" (page 88). Onboard Administrator Module 101 - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 102
certify the identity of Onboard Administrator and is required by the underlying HTTP server to establish a secure (encrypted) communications channel with the client web browser. certificate by the certifying authority. 102 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 103
Item Version MD5 Fingerprint SHA1 Fingerprint Description Version number of current certificate. A validation of authenticity embedded in the certificate. A validation of authenticity embedded in the certificate. Required Information Item Country (C) State or Province (ST) City or Locality (L) - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 104
the resolved web address to the name that appears in the The Onboard Administrator name that appears in the browser web address box. 104 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 105
Item Possible values Description certificate. For example, if the web address in the address box is https://oa-001635.xyz.com, then the value must be oa-001635.xyz.com. Select Standby OA Host Name to include a request for a Standby Onboard Administrator certificate. Enter the information in the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 106
used to send Onboard Administrator syslog messages to a remote server on the network for persistent storage. The syslog messages are additional information. Windows does not have native support for remote system logging. Any application that Configuring HP Integrity Superdome 2 compute enclosures and - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 107
• Enclosure Event 0x07: Administrator Rights Changed • Enclosure Event 0x08: Enclosure Shutdown Pending • Enclosure Event 0x09: Enclosure Topology Changed • Enclosure Event 0x10: Fan Status Changed • Enclosure Event 0x11: Fan Inserted • Enclosure Event 0x12: Fan Removed • Enclosure Event 0x14: - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 108
0x1020: User Enabled • Enclosure Event 0x1021: User Disabled • Enclosure Event 0x1201: Flash Pending • Enclosure Event 0x1202: Flash Started • Enclosure Event 0x1203: Flash Progress 108 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 109
a remote host, select the Enable remote system logging check box. Box Syslog Server Address Port Possible value where ### ranges from 0 to 255 An integer between click Apply. Standby Onboard Administrator screen When a second HP Superdome 2 Onboard Administrator is placed in the enclosure, it - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 110
static IP settings is selected) The IP address for the primary DNS server The IP address for the secondary DNS server The name of the Onboard Administrator. The default for this box is Upload tab" (page 106). 110 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 111
. The DNS name of the iLO within the server blade. NOTE: Not applicable for HP Integrity Superdome 2 server blades or storage blades. The status of the DVD connection to the server blade. A status of Incompatible Firmware means the DVD feature is not supported with the iLO firmware installed on the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 112
on or off one at a time or as groups, depending on the checkboxes. Virtual Power NOTE: This menu is not available for HP Integrity Superdome 2 server blades or storage blades. Button Momentary Press Press and Hold Cold Boot Reset Description This button mimics a physical momentary press of the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 113
blade in the device bay. iLO NOTE: This menu is not present for HP Integrity Superdome 2 server blades. The iLO for the server blade in the device bay is available by clicking iLO. The server-generated iLO page appears, which is separate from Onboard Administrator. The Onboard Administrator provides - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 114
blade is partnered with. This information does not display if there is no partner device. NOTE: Not applicable for HP Integrity Superdome 2 server blades. Diagnostic Information Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a failure has - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 115
to the Virtual Connect Manager to configure the server blade profile. NOTE: Not applicable for HP Integrity Superdome 2 server blades. CPU Status Item Resource Path Status FRU Read Status Indictment Status Description The resource path for the processor socket. The overall status of the processor - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 116
the status of the temperature sensor. The status matches the graphic presentation of the temperature. Graphic presentation of temperature Device Bay Information tab 116 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 117
the server blade A relocatable serial number assigned to the server blade The universally unique identifier assigned to the server blade Number Speed (MHz) Part Number Description The resource path to the processor socket Model of processor Clock speed of the processor Processor part number used to - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 118
Socket 0 or 1 Item Resource path Part Number Manufacturer Speed (MHz) Size (MB) Description Path to DIMM socket UID light on the server blade on (blue) or off (gray) for identification of the selected server blade. Interconnect bays HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 119
of last download. To view updated information, click the Refresh button. The Virtual Power menu enables you to turn an interconnect device on or off. HP recommends that only one device be turned on or off at a time using this feature. The UID State menu is used to set the UID - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 120
Administrator. Possible values are OK or Error. Device has failed; status was requested by the Onboard Administrator. Possible values are OK or Error. 120 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 121
interface. Management URL Web address of the interconnect management interface. User Assigned Name A name assigned to the interconnect by the user. If supported, the name is assigned using the interconnect Management Interface. Part Number The part number to be used when ordering an additional - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 122
. Port Mapping - Interconnect Bay screen The Port Mapping - Interconnect Bay screen provides a graphical view and a tabular view of the interconnect bay port mapping. 122 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 123
in the tabular view. Tabular view Item Interconnect Bay Port Port Status Device Bay Server Mezzanine Slot Server Mezzanine Port Device ID Description The number of the interconnect bay port in order from 1 to 16 Current status of the port The device bay corresponding with the interconnect port - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 124
depending on the checkboxes. XFM Bay Information - Bay screen The XFM Bay screen displays information about the bays where XFMs can be placed. 124 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 125
XFM Bay Status tab Status information Row Status Inlet Thermal Status Outlet Thermal Status Powered Diagnostic Information Row Device Identification Data Management Processor Temperature Description The overall status of the XFM. Possible values are Unknown, OK, Degraded, and Failed. The thermal - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 126
the Toggle On/Off button to turn UID on the XFM on (blue) or off (gray) for easy identification of the selected XFM. 126 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 127
GPSM bays GPSM Bay Summary screen In the Enclosure Information menu, the GPSM Bays category lists the Global Partition Services modules within the selected enclosure within the complex. Selecting the GPSM bays menu item directly opens the GPSM list with a grid that shows the status - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 128
is not responding. Possible values are OK or Error. Cooling Temperature is above the warning threshold. Possible values are OK or Temperature Warning. 128 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 129
between the power backplane and the server or switch bays. The Onboard Administrator will alert on fuse trips to enable you to reset fuses manually. When installing additional power supplies into the enclosure, different power supply part numbers are not supported in the same enclosure. The Onboard - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 130
For proper installation of the power supplies into a compute enclosure, see the HP Integrity Superdome 2 Installation Guide. Power and Thermal screen Item Enclosure Ambient Temperature Thermal Subsystem Status Power Subsystem Status Power Mode Present Power Power Limit Description This box - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 131
the redundancy mode setting in the Onboard Administrator to restore Power Subsystem status. See the Insight Display for corrective steps. The HP Superdome 2 Enclosure power management system enables you to customize the configuration of the enclosure. You can select from the different modes on - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 132
power subsystem efficiency varies based on load. Dynamic Power is not supported for low voltage on the Superdome 2 enclosure. Enclosure Power Allocation screen To set the power management in the enclosure in watts. 132 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 133
the enclosure. The power meter is useful for showing trends in power consumption and can assist in troubleshooting the power subsystem. Power Subsystem screen Power supplies available for use in Superdome 2 compute enclosures All power supplies in one enclosure must have the same part number. The - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 134
are Unknown, OK, Degraded, and Critical Error. The input status of the power supply. Possible values are Unknown, OK, Degraded, and Critical Error. 134 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 135
Item Present Output (Watts) Output Capacity (Watts) Description This value is a measure of the present output of the power supply in watts. The amount of power provided by the power supply displayed in watts. This is a measure of the output in dc watts generated by the power supply. Click Refresh - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 136
Indictment Indicates if the power supply has been indicted by the Superdome 2 Analysis Engine. Click the Refresh button to update the power supply information. Fans and cooling management Thermal Subsystem screen 136 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 137
are Redundant or Not Redundant Fan Location Rule The fan location rule indicates the proper location of the fans and the device bays that are supported. Fan status Column Fan Model Status Fan Speed Description The bay in the enclosure of the corresponding fan. The fan model name. The overall - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 138
138 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 139
bays, XFM bays and interconnect bay components. 15 Fan Rule All fan bays are used to support a maximum of 16 devices in the device bays. This includes eight HP Integrity Superdome 2 Server Blades. Fan Information - Bay screen Selecting a specific fan opens the Fan Information-Bay x screen, where - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 140
installation of the fans into the enclosure, see the HP Integrity Superdome 2 User Service Guide. Managing users Users/Authentication This section explains the levels of user rights recognized by the HP Superdome 2 Onboard Administrator and provides detailed procedures to configure the management - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 141
of HP Superdome 2 Onboard Administrator to user permissions enables the maintenance of server blade bays HP SIM is used, Onboard Administrator can integrate with HP SIM and use HP SIM users to enable a single login from HP SIM into Onboard Administrator. For more information, see "HP SIM Integration - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 142
different. Autologin is not supported for interconnect modules, and Scenario 1: A member of an organization must have full access to the servers in bays 1-8 to view logs, control power, and use the remote console. Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 143
Click the Add User button to save settings. The Edit Local User screen appears. Edit Local User User information Item Username Password Password Confirm Full Name Contact Possible value Description 1 to 40 characters, including all alphanumeric A maximum of 30 user accounts can be added, - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 144
, then all open sessions for that user account are terminated (signed out). The user must log on again after the privilege level change. 144 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 145
device bay if restricting permission to a single server in a double-denser server blade. User Permissions Item Description Onboard Administrator Bays . There are two methods for uploading certificates for use in HP Superdome 2 Onboard Administrator: • Paste certificate contents into the text - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 146
the X.500 standard, it is significantly simpler. LDAP also supports TCP/IP and is an open protocol. Use the Directory DNS name of the name of the domain of the directory directory server or the name of the service. domain 0 to xxxx The port used for LDAP communications. The HP Integrity Superdome - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 147
an LDAP certificate to the Onboard Administrator to establish a trusted relationship with the LDAP server. You can upload a maximum of three certificates. Upload certificates for use in HP Superdome 2 Onboard Administrator in the following ways: • Paste certificate contents into the text box, and - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 148
gives the user the most privileges is identified. A successful test reports the directory group with the highest privilege levels for the authenticated user. 148 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 149
tests that have run and the results of the tests. Directory Test Controls The user name and password are sent to the LDAP server for authentication before the User Authentication and User Authorization tests are performed. Directory Groups Item Check box Group Name Privilege Level Privilege Level - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 150
dash (-), the underscore (_), and the space. The description of the LDAP group, a more readable version of the group name, or other useful information. 150 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 151
Group Permissions Check box Onboard Administrator Bays All Device Bays Selected Device Bays All Interconnect Bays Selected Interconnect Bays Description Gives the user permissions for the Onboard Administrator bays and enables the user to see the fans and power supplies. If the user privilege - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 152
Interconnect Bays Gives the user permissions for only the selected interconnect bays Click the Update Group button to save settings. SSH Administration screen 152 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 153
public key. Each key is associated with the Administrator account. HP SIM Integration screen Superdome 2 Onboard Administrator supports SSO with trusted applications, such as HP SIM. This feature enables you to be logged in to an HP SIM station that can manage and is trusted by Onboard Administrator - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 154
subject name by selecting Subject when authenticating directory users with a directory server. To save settings, click the Apply button. Two-Factor Authentication Certificate authority that issued the certificate 154 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 155
. There are two methods for uploading certificates for use in HP Superdome 2 Onboard Administrator: • Paste certificate contents into the text box of user signed in to the enclosure. Possible values are Local, LDAP, or HP SIM. The type of session of the signed-in user. Possible values are - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 156
is not Onboard Administrator. Onboard Administrator creates a route table entry for each server iLO 3 IP address in an enclosure. This enables Onboard Administrator to conduct IP complete isolation of those networks. 156 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 157
8 HP Integrity Superdome 2 IOX Enclosures Each IOX enclosure in the complex can be selected from the left navigation tree. Clicking the IOX name opens the main status page - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 158
. The number of the IOX enclosure configured by dipswitches on the IOX enclosure hardware. The name of the company that manufactured the IOX enclosure. 158 HP Integrity Superdome 2 IOX Enclosures - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 159
Item Description Part Number The part number to be used when ordering an additional IOX enclosure of this type. Spare Part Number The part number to be used when ordering a replacement IOX enclosure of this type. Serial Number The unique serial number of the IOX enclosure. Engineering Date - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 160
values are Unknown, OK, Degraded, and Critical Error. The input status of the power supply. Possible values are Unknown, OK, Degraded, and Critical Error. 160 HP Integrity Superdome 2 IOX Enclosures - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 161
on thermal and power measurements. The performance of each fan is monitored, and Onboard Administrator reports any failures or warnings to the system log and HP SIM (when SNMP is enabled). IOX Thermal Subsystem screen 161 - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 162
RPM. When a fan module fails, the remaining fans automatically compensate by adjusting fan speeds. To update information on this page, click the Refresh button. 162 HP Integrity Superdome 2 IOX Enclosures - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 163
If a device is not present, the check box is disabled and the port cannot be viewed. The server blades are mapped to the interconnect bays in the following manner: Superdome 2 server blade • Embedded NICs 1 and 3 (ENET:1 and ENET:3) map to interconnect bay 1. • Embedded NICs 2 and 4 (ENET:2 and ENET - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 164
is available from the Onboard Administrator serial port, management port, or service port and provides access to all Onboard Administrator commands and information. information about the CLI, see the HP Integrity Superdome 2 Onboard Administrator Command Line Interface User Guide. 164 Using the CLI - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 165
Administrator CLI using the serial port, management port, or service port. 2. Log into the Onboard Administrator with the Administrator HP Integrity Superdome 2 Onboard Administrator Command Line Interface User Guide. Configuring Superdome 2 server blade iLO 3 IP addresses Each Superdome 2 server - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 166
Windows. If the laptop or PC is running Linux, you must probably manually set the network port to 169.254.2.1 with a netmask of 255.255.0.0. • does not support routing from the service port to an interconnect module management processor. However, if the interconnect module supports the serial - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 167
the Upload button. • URL: If the configuration file is located on a web server, enter an http:// path to it. The maximum number of characters in the the retrieved current configuration does not contain any user passwords. You can manually edit the script to add the user passwords after the user name - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 168
The text file also displays the current configuration for the enclosure. USB Support This box appears when a USB key is detected in the Active , the retrieved current configuration does not contain any user passwords. You can manually edit the script to add the user passwords after the user name on - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 169
Troubleshooting Onboard Administrator error messages The error message types are: • Soap Response Errors: These are the general errors reported by the gSoap service signal internal problems with the actual gSoap service itself. writing to the enclosure system log. 16 Could not fork a process. 17 An - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 170
time zone failed. 65 Setting the enclosure UID failed. 66 Setting the UID for the submitted interconnect failed. 67 Resetting the submitted interconnect failed. 170 Troubleshooting - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 171
in the RIBCL response. 103 Could not determine the IP address of the management processor for the requested blade. 104 Could not locate a Primary NTP server. 105 You must set at least one (1) trusted host before enabling trusted hosts. 106 Could not set the LCD pin. 107 Could not create the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 172
management processor auto-login feature is not supported. 119 The maximum number of EBIPA DNS servers has already been reached. 120 The HP SIM station already in trusted list. 133 HP SIM station name not found. 134 HP SIM SSO API received a bad parameter. 135 The maximum number of HP Troubleshooting - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 173
not supported. 163 The upload to the specified URL failed. 164 The Onboard Administrator did not fail over. 165 The blade is in a powered off state. 166 Could not get the blade CPQ key. 167 The IP manager does not exist. 168 There is no SSH key installed. 169 There was a problem - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 174
is not ready. 238 Power off (or remove) partner blade. 239 The current firmware does not support this operation. 240 Serial Number update requires newer firmware version. See 'UPDATE DEVICE' command. 241 The groups with administrator privilege, to enable two-factor authentication. 174 Troubleshooting - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 175
to permissions. 300 Error uploading to USB media. 301 An invalid number of GUIDs was passed to the OA. 303 Invalid session timeout. Session timeout must be 502 Invalid response. No connection or network busy. 503 Web server busy or in service. 605 A partition with that name or number already exists. - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 176
nPartition. 714 Exceeded number of vPars supported by a single blade. 715 Exceeded number of vPars supported in this complex. 716 Unable to Please refer to the system log for additional details. 721 A Boot Service Processor is not assigned to this vPar. 722 The maximum number of 176 Troubleshooting - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 177
identifier. 925 Maximum number of partition specifications has been reached. 926 Partitioning operation was unsuccessful (complex firmware returned an error) 1001 Problem encountered when trying to retrieve GPSM info/status. 1002 The power request for an xbar was denied. 1003 You must be on - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 178
resume session. 11 Insufficient privileges. Onboard Administrator factory default settings When resetting the HP Superdome 2 Onboard Administrator to factory defaults, the administrator password is not reset to factory ), see "Recovering the administrator password" (page 17). 178 Troubleshooting - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 179
any certificates on the Onboard Administrator. Onboard Administrator SNMP traps The HP Superdome 2 Onboard administrator supports the following SNMP traps. Trap ID 22001 22001 22003 22004 22005 22006 power subsystem line voltage problem cpqRackPowerSubsystemOverloadCondition Enclosure power - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 180
Analysis Engine Critical or Fatal event FlexFabric Cmdr Power Subsystem Minor event FlexFabric Cmdr Power Subsystem Major event FlexFabric Cmdr Power Subsystem Critical event 180 Troubleshooting - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 181
Controllers install DC certificates from the CA of the organization. This process occurs when the Enterprise Root CA service is added to a server in Active Directory. HP strongly recommends using an Enterprise Root CA to minimize the complexities of requesting and accepting DC certificates from - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 182
or the name of one of your DCs. See the Troubleshooting section for more information on verifying that the DC is of a server name forcing the DNS servers defined for the domain to offer DCs. For simplicity during initial setup, HP recommends you Services Authentication to Microsoft Active Directory - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 183
4. Click the Details tab, and then click theCopy to File... button. 5. IMPORTANT: Select Base-64 encoded x.509 (.CER) from the list of export options. Click the Next button. 6. Provide a name and location for the file (c:\dccert.cer) and click the Finish button to complete the wizard. 7. Locate the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 184
created in the Active Directory. 4. Assign this group full administrative privileges over all server bays and interconnect bays and then click the Add button. 5. Create a , and do not allow the group access to Server Bays, but do allow access to Interconnect bays, and then click the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 185
is jallen, you cannot login as jallen because this format is not now supported by LDAP. 4. Log off or sign out of Onboard Administrator, and then then the account has no access to any server blades, but full access to interconnect bays. Troubleshooting LDAP on Onboard Administrator To be sure that - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 186
for troubleshooting SSL is to go to the DC, and then run the following command: C:\netstat -an | find /i "636" If the server is listening for requests on port 636,the following response appears: TCP 0.0.0.0:636 0.0.0.0:0 LISTENING One of the problems can be that the - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 187
complete the installation or upgrade of your product and to enable improved delivery of your HP Warranty, HP Care Pack Service or HP contractual support agreement. HP Insight Remote Support supplements your monitoring, 24x7 to ensure maximum system availability by providing intelligent event Before - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 188
information: • HP Integrity Superdome 2 Onboard Administrator Command Line Interface User Guide • HP Integrity Superdome 2 Partitioning Administrator Guide You can find these documents from the Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals Typographic - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 189
WARNING! A warning calls attention to important information that if not understood or followed will result in personal injury or nonrecoverable system problems. CAUTION: A caution calls attention to important information that if not understood or followed will result in data loss, data corruption - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 190
NOTE: Time zones must be entered exactly as they appear. The following table provides the African time zone settings that are supported by the Onboard Administrator. Africa/Abidjan Africa/Accra Africa/Addis_Ababa Africa/Algiers Africa/Asmera Africa/Bamako Africa/Bangui Africa/Banjul Africa/Bissau - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 191
America/Bogota America/Boise America/Buenos_Aires America/Cambridge_Bay America/Cancun America/Caracas America/Catamarca America/Cayenne America/Cayman America/Chicago America/Chihuahua America/Cordoba America/Costa_Rica America/Cuiaba America/Curacao America/Dawson America/Dawson_Creek America/ - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 192
Universal time zone settings NOTE: Time zones must be entered exactly as they appear. The following table provides the Universal time zone settings that are supported by the Onboard Administrator. CET CST6CDT EET EST EST5EDT Etc/GMT Etc/GMT-2 Etc/GMT+2 Etc/GMT-3 Etc/GMT+3 Etc/GMT-4 Etc/GMT+4 Etc - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 193
Time zones must be entered exactly as they appear. The following table provides the Oceanic time zone settings that are supported by the Onboard Administrator. Atlantic/Azores Atlantic/Bermuda Atlantic/Canary Atlantic/Cape_Verde Atlantic/Faeroe Atlantic/Jan_Mayen Atlantic/Madeira Atlantic/Reykjavik - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 194
must be entered exactly as they appear. The following table provides the Polar time zone settings that are supported by the Onboard Administrator. Antarctica/Casey Antarctica/Davis Antarctica/DumontDUrville Antarctica/Mawson Antarctica/McMurdo Antarctica/Palmer Antarctica/South_Pole Antarctica - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 195
erasable programmable read-only memory First in, first out. Global Partition Services module. Hypertext transfer protocol secure sockets. Interface adapter. Internet Control Message Protocol. Integrated Lights-Out 3. I/O expansion enclosure. Lightweight Directory Access Protocol. Media Access - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 196
HP contact information, 187 Technical support, problems, 169 directory settings Directory Settings screen, 146 directory test settings, 147 DNS server, 110 document related documentation, 188 documentation HP services unavailable, 69 firmware update screen, 74 firmware upgrade utility, troubleshooting - HP Integrity Superdome 2 16-socket | HP Integrity Superdome 2 Onboard Administra - Page 197
HP, 187 HP contact information, 187 Technical support, 187 telephone numbers Before you contact HP, 187 HP contact information, 187 Technical support, 187 testing, directory services, 147 testing, remote log, 109 Thermal subsystem fan zones tab, 137 thermal subsystem screen, 136 troubleshooting
HP Integrity Superdome 2 Onboard
Administrator User Guide
Abstract
This document contains specific information that is intended for users of this HP product.
HP Part Number: AH337-9001G
Published: November 2013
Edition: 9