HP Integrity Superdome 2 16-socket HP Integrity Superdome 2 Onboard Administra - Page 160
IOX Power Subsystem screen, Power supplies available for use in IOX enclosures, Power Supply summary
View all HP Integrity Superdome 2 16-socket manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
IOX Power Subsystem screen The Power Subsystem screen shows the overall status of the IOX enclosure power subsystem and information about each power supply in the IOX enclosure. Power supplies available for use in IOX enclosures All power supplies in one IOX enclosure must have the same part number. The Onboard Administrator identifies which power supplies must be replaced by displaying a caution icon. Power Supply summary The Power Subsystem screen provides status on the power subsystem, on each individual power supply, and fault conditions. Item Power Subsystem Status Redundancy State Description The overall power status of the IOX enclosure. Possible values are Unknown, OK, Degraded, or Critical Error. Indicates the redundancy status of the power subsystem. Possible values are Redundant, Not Redundant, or Redundancy Lost. This screen provides status on the power subsystem and on each individual power supply. Power Supply status Item Bay Model Status Input Status Description The bay in the IOX enclosure of the corresponding power supply. This box displays only populated bays. Empty bays do not appear in this table. The power supply model name. The overall status of the power supply. Possible values are Unknown, OK, Degraded, and Critical Error. The input status of the power supply. Possible values are Unknown, OK, Degraded, and Critical Error. 160 HP Integrity Superdome 2 IOX Enclosures