12050 12069 12091 12101 12102 12103 12109 12119 12120 12121 12127 12128 12129 12130 12131 12132 12135 12143 12144 12149 Error Warning Warning Error Error Error Warning Warning Warning Warning Warning Warning Warning Warning Warning Error Warning Warning Warning Error A CPU module's temperature has exceed the high temperature threshold or a CPU power module fault has occurred. As a result of this event, the CPU has been inhibited. The Cell must be powered off then on using the MP's hpevtCpuTempExceedHiThres - 12050 PE command to clear. in HPIFPTRAP.MIB SFW detected an error while writing to stable hpevtSFWDetErrStablStorFlsh - 12069 in store flash. HPIFPTRAP.MIB hpevtInlckOpenPCIPwr - 12091 in PCI interlock open with PCI power applied. HPIFPTRAP.MIB Fault detected on low drop out regulator on hpevtFaltDetDropRegIO - 12101 in I/O backplane. HPIFPTRAP.MIB Fault detected on low drop out regulator on hpevtFaltDetDropRegManBckPlne - main backplane. 12102 in HPIFPTRAP.MIB Fault detected hot swap controller of specified core IO. hpevtFaltDetHotswpCoreIO - 12103 in HPIFPTRAP.MIB An error occurred while retrieving the crossbar chip number. hpevtErrRetrvCrssbarChipNmbr - 12109 in HPIFPTRAP.MIB One or more of the cells are not configured hpevtCellNotCfgCLMMode - 12119 in for Cell-Local Memory (CLM) mode HPIFPTRAP.MIB Double DRAM chip sparing events have been hpevttDoblDramInvoke - 12120 in invoked. HPIFPTRAP.MIB A platform error was detected by the firmware/hardware, and corrected by using hpevtErrCrssbarCrctByHW - 12121 in a spare channel. HPIFPTRAP.MIB A platform error was detected by the firmware/hardware, and corrected by using hpevtErrCrssChipBckPln - 12127 in a spare channel. HPIFPTRAP.MIB A platform error was detected by the firmware/hardware, and corrected by using hpevtErrCeLLIO - 12128 in a spare channel. HPIFPTRAP.MIB Multiple platform errors were detected and hpevtMltPltFrmErrCellBckPln - 12129 in corrected by the firmware/hardware. HPIFPTRAP.MIB Multiple platform errors were detected and hpevtMultPltFrmErrCrssChpBckPln - corrected by the firmware/hardware. 12130 in HPIFPTRAP.MIB Multiple platform errors were detected and hpevtMultPltFrmErrCeLLIO - 12131 in corrected by the firmware/hardware. HPIFPTRAP.MIB The server ID does not match the cabinet type. hpevtServIDNotMatchCab - 12132 in HPIFPTRAP.MIB Duplicate DIMM serial numbers have been detected. Data field gives physical location of DIMM. Check for other events specifying hpevtDupDimNumDetect - 12135 in other DIMMs with same serial number. HPIFPTRAP.MIB The MP has lost lan communication with the hpevtMPLostUPS - 12143 in UPS. HPIFPTRAP.MIB The MP has re-gained lan communication hpevtMPGainLanCommUPS - 12144 in with the UPS. HPIFPTRAP.MIB An unrecoverable processor interrupt occurred while in IPF firmware. The data value is the processor IFA. hpevtUnrecovProcIFAinterptInFW 12149 in HPIFPTRAP.MIB 58 Management Agents Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151

hpevtCpuTempExceedHiThres - 12050
in HPIFPTRAP.MIB
A CPU module's temperature has exceed the
high temperature threshold or a CPU power
module fault has occurred. As a result of this
event, the CPU has been inhibited. The Cell
must be powered off then on using the MP's
PE command to clear.
Error
12050
hpevtSFWDetErrStablStorFlsh - 12069 in
HPIFPTRAP.MIB
SFW detected an error while writing to stable
store flash.
Warning
12069
hpevtInlckOpenPCIPwr - 12091 in
HPIFPTRAP.MIB
PCI interlock open with PCI power applied.
Warning
12091
hpevtFaltDetDropRegIO - 12101 in
HPIFPTRAP.MIB
Fault detected on low drop out regulator on
I/O backplane.
Error
12101
hpevtFaltDetDropRegManBckPlne -
12102 in HPIFPTRAP.MIB
Fault detected on low drop out regulator on
main backplane.
Error
12102
hpevtFaltDetHotswpCoreIO - 12103 in
HPIFPTRAP.MIB
Fault detected hot swap controller of
specified core IO.
Error
12103
hpevtErrRetrvCrssbarChipNmbr - 12109
in HPIFPTRAP.MIB
An error occurred while retrieving the
crossbar chip number.
Warning
12109
hpevtCellNotCfgCLMMode - 12119 in
HPIFPTRAP.MIB
One or more of the cells are not configured
for Cell-Local Memory (CLM) mode
Warning
12119
hpevttDoblDramInvoke - 12120 in
HPIFPTRAP.MIB
Double DRAM chip sparing events have been
invoked.
Warning
12120
hpevtErrCrssbarCrctByHW - 12121 in
HPIFPTRAP.MIB
A platform error was detected by the
firmware/hardware, and corrected by using
a spare channel.
Warning
12121
hpevtErrCrssChipBckPln - 12127 in
HPIFPTRAP.MIB
A platform error was detected by the
firmware/hardware, and corrected by using
a spare channel.
Warning
12127
hpevtErrCeLLIO - 12128 in
HPIFPTRAP.MIB
A platform error was detected by the
firmware/hardware, and corrected by using
a spare channel.
Warning
12128
hpevtMltPltFrmErrCellBckPln - 12129 in
HPIFPTRAP.MIB
Multiple platform errors were detected and
corrected by the firmware/hardware.
Warning
12129
hpevtMultPltFrmErrCrssChpBckPln -
12130 in HPIFPTRAP.MIB
Multiple platform errors were detected and
corrected by the firmware/hardware.
Warning
12130
hpevtMultPltFrmErrCeLLIO - 12131 in
HPIFPTRAP.MIB
Multiple platform errors were detected and
corrected by the firmware/hardware.
Warning
12131
hpevtServIDNotMatchCab - 12132 in
HPIFPTRAP.MIB
The server ID does not match the cabinet
type.
Error
12132
hpevtDupDimNumDetect - 12135 in
HPIFPTRAP.MIB
Duplicate DIMM serial numbers have been
detected. Data field gives physical location
of DIMM. Check for other events specifying
other DIMMs with same serial number.
Warning
12135
hpevtMPLostUPS - 12143 in
HPIFPTRAP.MIB
The MP has lost lan communication with the
UPS.
Warning
12143
hpevtMPGainLanCommUPS - 12144 in
HPIFPTRAP.MIB
The MP has re-gained lan communication
with the UPS.
Warning
12144
hpevtUnrecovProcIFAinterptInFW -
12149 in HPIFPTRAP.MIB
An unrecoverable processor interrupt
occurred while in IPF firmware. The data
value is the processor IFA.
Error
12149
58
Management Agents Event Tables